THERMOMETRY BRIDGE METROLOGY STANDARD

 

F18 Thermometry Bridge Primary Standard. Resistance Thermometry Bridge. Accuracy +/- 0.1 ppm

The Model F18 Thermometry Bridge Primary Standard is designed specifically for resistance thermometry to provide you with the best possible accuracy.
The 25Hz or 75Hz operating frequency provides fast, continuous measurement with high immunity to thermal emfs and supply frequency noise sources. Practical measurements involve cables, connectors and imperfect operating environments, the F18 Thermometry Bridge achieves its full specification under a wide range of real operating conditions.

F18 Precision Thermotry Bridge

The F18 Thermometry Bridge includes a wide range of features specifically tailored for temperature metrology.
These include programmable excitation current,
root 2 current, analogue outputs, selectable source
impedance, gain and filter bandwidth.
Manual or automatic bridge balancing together with manual or automatic control (IEEE interface) of the instrument ensure that the F18 can provide
solutions in a wide range of measurement
applications.

The F18 Thermometry Bridge can be used with one or more switchboxes for multi channel calibration.

Features

Bandwidth Selectable: 0.5, 0.1 or 0.02 Hz
External Standard AC/DC standard resistor or resistance thermometer
Sensor current 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50mA or x root 2 any value
Sensor current frequency User selectable frequencies: 25 or 75 Hz with 50 Hz supply
30 or 90 Hz with 60 Hz supply
Phase locked to supply frequency.
Bridge balancing modes Automatic: via full self balance algorithm.
Manual: via front panel switches (to 0.1 ppm) and analogue meter (interpolated to 0.01 ppm).
Self check modes Zero: verifies bridge zero accuracy
Unity: verifies bridge slope accuracy
Lead connections True four wire connections for resistance thermometer (Rt) and standard resistor (Rs). Accuracy is unaffected by series lead resistance, permitting measurements with long cables (100 metres for 25.5 Ohm SPRT referenced to a 25 Ohm resistor)
Quadrature balance Eliminates effects of thermometer, resistor and cable reactance
Active input guard Eliminates effects of leakage from any terminal to ground
Analogue output Null balance: ±10V (unfiltered)
Programmable: 0-10V (3 scale ranges)
Accessories
SB148 10 channel auto/manual multiplexer, with individual preset "keep warm" current
SB148/01 As SB148, with 4 individual "keep warm" currents per channel
SB158 Driver/interface for up to 2 x SB148 or 5B1 48/01 multiplexers (Specify RS232 or IEEE
SB158/01 Driver/interface for up to 6 x 5B148 or SB148/01 multiplexers (Specify R5232 or IEEE)
F18 AS1 System F18 complete with SB148 and SB158 multiplexer in 19"/1 6U cabinet complete with power distribution and cutout
F18 AS2 System As AS1 system, but with SB148/01 multiplexer
RW1, 10, 25, 100, 300 "Wilkins" AC/DC Standard Resistor. Values: 1, 10, 25,100 and 300 ohms
RTWE Thermal enclosure for RW resistors
FA1 Co-axial cable set with BNC connectors at both ends
FA2 Co-axial cable set with BNC connectors at one end
FA3 4 terminal to 2 x BNC connector, adapter box
FA-KIT FA1, FA2 and FA3 cable set
TMS ITS-90 temperature measurement and data acquisition software