DUAL PORT PRESSURE CALIBRATORS |
|
|
BetaGauge 321 Dual Sensor Pressure Calibrator |
|
BetaGauge 321
Pressure calibrator.
BetaGauge 321 Pressure calibrator
provides 0.025% FS accuracy on 2 internal, isolated, stainless steel
pressure sensors, while external connection supports all BetaPort-P
pressure modules.
Accurate to 0.2°F, Pt100 RTD input is provided for temperature
measurements, and product also measures 4-20 mA loop current and up to
30 Vdc. Unit supports up to 3 simultaneous measurements in any
combination. It is available in 15 psi/1,500 psi or 30 psi/3,000 psi
ranges or customized with
any two ranges selected from 5, 15, 100, 300, 500, 1000, 3000, 5000, or
10,000 psi..
|

Dual Port Pressure Calibrator |
-
Two isolated,
stainless steel, pressure
sensors with 0.025% F.S. accuracy
-
Temperature-compensation ensures accuracy
in field applications
-
External pressure
module connection supports
all BETA Port-P pressure modules 25 ranges for even more measurement
capability
-
Pt100 RTD input
for temperature measurement,
accurate to 0.1°C (0.2°F)
-
Measure 4-20 mA
input
-
Internal 24 V
Loop Power Supply can power
a transmitter under test
-
Measure up to 30
V DC
-
Large graphic
style LCD with backlight
|
|
|
|
|
|
|
-
Display can be configured
to display up to 3 inputs simultaneously (i.e. pressure 1,
pressure 2, and RTD or any combination of inputs)
-
Ideal for gas flow
calibration (custody transfer) applications
-
Switch test on Pressure
1, Pressure 2, or external pressure module
-
Operating mode layers
support simple measurements to complex applications
-
Up to five frequently
used setups to be stored; last setup automatically recalled
on
power-up
-
% Error and damping
functions
-
Small, rugged compact
design operates on four (4) standard AA batteries
|
|
Specifications
(18°C to 28°C
unless otherwise noted) |
|
|
Ranges |
| Available Pressure (select any
two) |
5 psi, 15, psi, 30, psi, 100 psi, 300
psi, 500 psi, 1000 psi, 3000 psi, 5000 psi, 10,000 psi |
| mA |
0 to 24.000 mA |
| Volts |
0 to 30.000 VDC |
| RTD |
-40°C to 105°C
(-40°F to 220°F) |
|
Engineering
Units |
psi, bar, mbar, kPa, kgcm2,
cmH2O@4°C, cmH2O@20°C,
mH2O@4°C, mH2O@20°C,
inH2O@4°C, inH2O@20°C,
inH2O@60°F, mmHg@0°C,
inHg@0°C, ftH2O@4°C,
ftH2O@20°C, ftH2O@60°F |
|
Accuracy |
|
Pressure
15 psi to 3000 psi
5 , 5000 , 10,000 psi |
±0.025% F.S.; for all ranges
±0.035% F.S.
|
|
mA |
±0.015% of rdg±0.002mA |
|
Volts |
±0.015% of reading ±0.002V |
|
RTD (ohms) |
±0.015% of rdg ±0.02 ohms;
or ±0.1°C @ 0°C for Pt100 |
Temperature Effect
No effect on accuracy on all functions from 15°C to 35°C
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
|
Temperature
Range |
| Operating |
-10
to +50 °C |
| Storage |
-20
to +60 °C |
|
Power
Requirements |
| Battery |
6
VDC, 4 AA cells required; included |
|
|