BetaGauge PI PRO Calibration Pressure Gauge

The BetaGauge PI PRO Calibration Pressure Gauge provides ±0.05% of full scale accuracy over
pressure ranges to 15,000 psig or 300 psia.
Readings may be displayed in any one of 18 standard engineering units or in 1 custom user-defined
unit to eliminate tedious conversion calculations.
BetaGauge PI PRO Calibration Test Pressure Gauge is CSA intrinsically safe.

 Pressure Calibration Test Gauge BetaGauge PI PRO
We accept credit cards and purchase orders
253-927-6186
253-927-6189

BetaGauge PI PRO Calibration Test Pressure Gauge

Model  Description  List Price  Sale Price 
PI-PRO  BetaGauge PI PRO Calibration Pressure Gauge  $860.00  $810.00 

The PI Pro Calibration Pressure gauge includes a 5-1/2 digit digital display.
The 0.65" numerals and companion bar graph provide an easy to read display, even from a distance.
A number of features provide additional ease of use.
The reading sample rate can be user adjusted to match the type of measurement required.
Other features include MIN/MAX function, Auto Power Off and backlight control.
In addition to a ZERO function that compensates for sensor drift, large residual system pressures
can be nulled using the TARE adjustment.

Standard Engineering Units
PSI, Bar, Kg/cm2, inH2O (4 °C, 20 °C or 60 °F), ft H2O (4 °C, 20 °C or 60 °F), mmH2O,
cmH2O (4 °C and 20 °C), mH2O (4 °C and 20 °C), Kpa, mBAR, inHg, mmHg, TORR

BetaGauge PIR-PRO Digital Pressure Gauge

Accuracy  Mechanical 
±0.05 % FS positive pressure
±0.1 % FS for 1.0 psi 
Dimensions
4.375" x 5.0" x 1.50" 
Input Pressure Ranges
10” H20*/20 mBAR; 1 psi*/70 mBAR; 15 psi/1 BAR,
30 psi/2 BAR; 100 psi/7 BAR; 300 psi/20 BAR;
500 psi/30 BAR; 1,000 psi/70 BAR; 2,000 psi/140 BAR;
3,000 psi/200 BAR; 5,000 psi/300 BAR;
10,000 psi/700 BAR; 15,000 psi/1035 BAR;
-15 to +15 psi*; -15 to +30 psi*; absolute 10, 30, -15 - 300 
Input Port
1/4" male NPT 
Display
5 Digits, 0.65" (16.53 mm) height
Bar Graph – 0 to 100% in 20 segments 
Temperature Compensation
0 °C to +50 °C (32 °F to +122 °F) to rated accuracy 
Power Battery
three (3), size AA alkaline batteries 
Media Compatibility
liquids and gases compatible with 316 stainless
steel, 30 C/V range non-corrosive gases and liquids 
Battery Life
1,500 hours without backlight;
2,000 hours at slow sample rate; 
Environmental
Operating Temperature
-10 °C to +55 °C
Storage
-20 °C to +70 °C (-4 °F to +158 °F) 
battery life can be displayed
on bar graph to
indicate the amount of time left
Low Battery Indicator
displayed icon near the end of battery life
Includes: manual, batteries 


Toll Free: 866-436-2430    Email: sales@hotektech.com