  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  

DIGITAL PRESSURE GAUGE


BetaGauge PI. Digital Pressure Gauge
BetaGauge
PI. Digital Pressure Test Gauge takes the concept of an analog Test Gauge, and brings it to a new level. The Digital Pressure Gauge PI combines the accuracy of digital technology with the simplicity of an analog gauge, and achieves performance, ease-of-use, and a feature set unmatched in the pressure measurement world. Setup of the BetaGauge P. I. Digital Pressure Test Gauge is fast and straightforward, through a menu-driven display, with minimal text, and intuitive functions, that is simple enough to allow the gauge to be used anywhere in the world, without the need for multilingual displays. And the availability of optional sanitary seals that meet 3A standards per specification 37-01 allow the gauge to be used in virtually any application.

Digital Pressure Gauge, Reference pressure gauge

P I. Digital Pressure Test Gauge

Very high accuracy compared to analog test gauges;
±0.05% F. S.; temperature compensated
Temperature compensated accuracy over 0 to 50 °C
Eight (8) standard pressure ranges
Displays in 18 standard or fully custom engineering units
Displays ambient temperature in °C or °F
Large, back-lit, 5-1/2 digit display with 0.65" high digits and
20 segment bar graph
Rugged stainless steel case meets NEMA 4/IP65
Password-protected “through the keypad” calibration
MIN/MAX recall
Adjustable TARE zeros large system offsets
User-configurable sample rate maximizes measurement performance and battery life
User-configurable damping smoothes readings from pulsating/plant air sources
Auto Shut-off for extended battery life
Low battery indicator
CSA intrinsically safe, Class 1, Div. 1 approvals pending

 

Standard Engineering Units
PSI, Bar, Kg/cm2, inH2O (4 °C, 20 °C or 60 °F), ft H2O (4 °C, 20 °C or 60 °F), cmH2O (4 °C and 20 °C),
mH2O (4 °C and 20 °C), Kpa, mBAR, inHg, mmHg, TORR
P I. Digital Pressure Test Gauge Specifications (0 °C to +50 °C, unless otherwise noted)
Input Ranges Mechanical
15 psi/1 BAR,
30 psi/2 BAR,
100 psi/7 BAR,
500 psi/30 BAR,
1,000 psi/70 BAR,
3,000 psi/200 BAR,
5,000 psi/300 BAR,
10,000 psi/700 BAR
Dimensions
4.375" x 5.0" x 1.50"
Accuracy

±0.05% FS Positive Pressure
±0.25% FS Vacuum/500 psi and below

Input Port
1/4" male NPT
Display
5 Digits, 0.65" (16.53 mm) height
Bar Graph – 0 to 100% in 20 segments
Temperature Compensation
0 °C to +50 °C (32 °F to +122 °F) to rated accuracy
Power Battery
three (3), size AA alkaline batteries
Battery Life
1,500 hours without backlight;
2,000 hours at slow sample rate;
battery life can be displayed on bar graph to
indicate the amount of time left
Low Battery Indicator
displayed icon near the end of battery life
Includes: manual, batteries
Media Compatibility
liquids and gases compatible with 316 stainless
steel
Environmental
Operating Temperature
-10 °C to +55 °C
Storage
-20 °C to +70 °C (-4 °F to +158 °F)