DAQPRO-5300 Eight
Channel Data Logger is battery
operated and is capable of sampling, processing and displaying
measurements without connecting to a computer. Designed to serve the
needs of professional data loggers, DAQPRO Eight Channel Data Logger is a professional,
cost-effective, compact and stand-alone data logging system that can
be used with a wide variety of applications.
This 16-bit,
high-resolution, eight-channel data logger offers the pros graphic
displays and analysis functions for measuring voltage, current and
temperature in real-time.
|
DAQPRO Eight
Channel Data Logger includes
eight input channels for measuring voltage, current and temperature.
Selectable ranges for each input are 0-20mA,
0-50mV, 0-10V, NTC, PT-100, Thermocouples (Type J, K, T), Frequency
(Input 1 only).
|
Inputs (DaqPRO
5300)
• 8 differential inputs
• Selectable type for each input: 0-24mA, 0-50mV, 0-10V,
NTC, PT-100, Thermocouple, Pulse and frequency (Input
1 only)
0-24mA
Range:
0-24mA
Resolution:
0.47µA
Accuracy:
±0.5% FS
Loop impedance: 195Ω
0-50mV
Range:
0-50mV
Resolution:
3µV
Accuracy:
±0.5% FS
0-10V
Range:
0-10V
Resolution:
200µV
Accuracy:
±0.5% FS
Input impedance: 125KΩ
Temperature NTC
NTC:
10/100KΩ resistor
Range:
-25 – 150ºC
Resolution:
0.05ºC
Accuracy:
±0.5% FS
Temperature PT-100
Range:
-200 – 400ºC
Resolution:
0.1ºC (7mΩ)
Accuracy:
±0.5% FS
The DaqPRO offers up to 8 PT-100 2 wire channels or 4 PT-100 3 wire
Channels
Temperature Thermocouple J
Range:
-200 – 1200ºC
Resolution:
0.1ºC (1µV)
Accuracy:
±0.5% FS
Cold junction compensation error: ±0.5ºC
Temperature thermocouple K
Range:
-250 – 1200ºC
Resolution:
0.1ºC (1µV)
Accuracy:
±0.5% FS
Cold junction compensation error: ±0.5ºC
Temperature thermocouple T
Range:
-200 – 400ºC
Resolution:
0.1ºC (1µV)
Accuracy:
±0.5% FS
Cold junction compensation error: ±0.5ºC
Internal temperature
Range:
-25 – 70ºC
Resolution: 0.1ºC
(1µV)
Accuracy: ±0.5% FS
Pulse counter (Input 1 only)
Optocoupler input
Range: 0-65,000
Input signal: 0-5V
Input impedance: 470Ω
band width:
0-50hz
Frequency meter (input 1 only)
Optocoupler input
Range:
20-4,000Hz
Input signal:
0-5V
Input impedance: 470Ω
General A to D specifications
Noise: 30µV rms
Internal linearity error: ±0.08% of FSR
Offset error: 0.1%
|
Open collector output
(Output 8)
Maximum current sink: 50mA (fuse
protected)
Input impedance:
50Ω
Communication
USB 1.1 compliant
Sampling
Capacity:
512KB
Analog sampling rate:
Variable,
1 sample/hour to
4,000 samples/sec,
1 channel
Analog sampling resolution: 16 bits
Man Machine Interface
• Full keyboard operation - enables manual programming
of the logger
• Graphic LCD 64x128 pixels
Power Supply
• Internal rechargeable 7.2V NiCa battery
• Built in battery charger
• External 9V to 12V DC input
• Battery life: 40 hours between charges
Operating Temperature Range
0 to 50°C
Casing
Plastic ABS box
Dimensions: 182x100x28 mm
Weight: 450gr
Standards Compliance
CE, FCC
Analysis Software
• Running on Windows 95/98/2000/ME/XP and NT
• Fast data download from the DaqPRO
• Data displayed in numeric or graphical display forms
• Graphical analysis tools such as Zoom and Cursors
• Storage of selected data on disk files
• Hard copy printing of the collected data
• Direct data export to EXCEL
• On-line retrieval and display of data in real-time
• Incorporating data processing functions
• Setting up the DaqPRO
• Calibrating the DaqPRO
• Defining new sensors
Accessories
• Carrying case
• Solar cell and battery for field data logging
• Weather box complies with the IP-67 standard for
protecting the DaqPRO while working in field applications.
Ordering Information
Part number Description
DaqPRO-5300 DaqPRO data logger, user manual,
carrying case, AC/DC adapter
SFTDAQ001 DaqLab Windows analysis software,
communication cable
DT177 Weather box
AC029 12V Solar cell and battery
AD21203 12V AC/DC adapter
DT180 USB communication cable |