  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

ESDC 30 ESD GENERATOR DISCHARGE SIMULATOR


ESDC 30 the ESD generator simulator is a part of the immunity standards described by the International Electronic Commission (IEC). The IEC 1000-4-2 standard specifies a method of establishing a common and reproducible basis for evaluating the performance of electric and electronic equipment when subjected to ESD pulses. 


Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Considerable efforts have been made to reduce the weight and the size of the test pistol to an absolute minimum.
The shape has proven to offer optimal ergonomics when working with contact discharge as well as
with air discharge.

The ESD generator is divided into two parts. A small and lightweight pistol only containing the necessary high voltage electronics and a controller containing all the control and user interface.
A thin and highly flexible cable with no voltages exceeding 24V connects the two parts.

The pistol has the following characteristics:

  • Low weight, only 440 grams., with a good 'balance' insuring a pleasant working situation, even for longer periods of time

  • One button for discharge

  • Simple change between different test fingers

  • The standard - ESDP 33 - pistol is equipped with 330 ohms / 150pF discharge network

  • A special pistol - ESDP 15 - conforming to the IEC 801-2 (84), equipped with 150 ohms / 150 pf discharge network is available

The controllers characteristics:

  • Easy and intuitive operation with soft-keys and function keys

  • Readable high contrast display with backlight

  • Programming facilities

  • User memory and library inc. level I - IV according to IEC 801-2 and IEC 1000-4-2

  • Portable with the possibility of battery use

  • Possibility for automatically interruption of test at EUT failure

  • Automatic detecting of test finger present

A new and unique function in the ESD simulator is the so-called fail/stop function. The fail/stop function makes it possible to halt a programmed test or sequence when the EUT fails and this fault is detected by a control circuit. The fail/stop function is controlled by a optical fiber input. There exist thus no galvanic coupling between the EUT and the simulator which can create problems.
The combination of the fail/stop function and the possibility of halting a test sequence is particular useful when examining if is a change made is for the better or worse.
Programmed test sequences can easily be saved in the user memory for later use. It is therefore easy and accurate to repeat a previous test.

Pistols with other discharge networks are available on request.

Technical specifications of the ESDP 33 standard pistol

Conforms to IEC 1000-4-2 (1994) and IEC 801-2 (1991)

   Air discharge voltage 0.5 - 15 kV, 0.1 kV steps
   Contact discharge 
   voltage
0.5 - 8 kV, 0.1 kV steps
   Polarity Positive and negative
  Voltage tolerance < ±5 %, 0.5 - 2 kV
< ±3 %, 2.0 - 15 kV
  Discharge network 330 ohms /150 pF, < ± 10 %
  Discharge tips Point tip for contact and ball tip for air discharge as per IEC. Interchangeable, plug in fitting. Automatic detection of discharge tip type
  Holding time > 5 sec
  Rise time 0.7 - 1.0 ns with contact tip as per IEC
  Triggering Trigger button. Triggering on ESDP 33 also possible
  Shape Hand held ergonomic pistol shape with ¼ inch fitting for tripod
  Weight 440 grams (0.97 lb.)
Technical specifications of the ESDC 30 controller
  Visual indication Graphical LCD display (B/W) with back light
  Controls 4 soft keys plus UP, DOWN , RETURN, TRIG and 0-I (on/off) keys
  Inputs Optical input and 9 pin D-sub controlling the fail/stop function
  In/Out 12 pin connector to pistol. No high voltages in cable
  Acoustic indicator Acoustic indication of arcing. User selectable volume Off / Low / Mid / High
  Memory E²PROM for storing vital data and user memory
  Power Mains input 115/230/240 V AC max. 10 VA. With optional build in battery pack max. 20 VA
  Dimensions 240 x 180 x 100 mm
  Weight 2.5 kg (5.5 lb.)
3.0 kg (6.6 lb.) with battery pack

The standard ESDC 30 ESD Generator kit includes ESDP 33 standard pistol, discharge return cable and a set of 470 k ohms molded carbon high voltage / high current resistors with cable.

Options include ESDP 15 pistol in conformity with IEC 801-2 (1984) air, 150 ohms / 150pf.

Pistols with other discharge networks are available on request.