DB231 LCR Component Capacitor Tester is specially
designed for manual as well as automatic high accuracy and high-speed
testing of capacitors or other LCR applications.
The instrument is reliable, user-friendly and easy to set up to any
test application on production lines,
in quality control departments
or in laboratories.
|
DB231 LCR Component Capacitor Tester
|
| Our
Price: |
Contact us for
pricing |
| Phone:
|
253-927-6186
866-318-6186 |
| Fax:
|
253-927-6189 |
| email:
|
sales@hotektech.com |
|
|
|
|
|
|
|
Dual, triple and quadro frequency tests are popular to give an immediate
presentation of
capacitance and loss factor measurements over a range of frequencies.
As standard the
instrument has a built-in comparator for deviation measurements,
IEEE488 (GPIB) and RS232C data interfaces as well as handler interface
(opto-coupler type) with 12+4 bins for production sorting. The
high-speed data interfaces may be used for an external computer in
order to control the system, or for collection of data for statistics
and analysis.
Bin sorting with up to
12 bins for capacitance for 1st frequency and up to 4 bins
for tan d
using 2nd frequency. Or tan d
may be measured at several frequencies using the 4 bins for different
levels of the dissipation factor.
|
The
standard fitted PCMCIA card is the smart way of storing set-ups.
Fail-safe loading of set-ups to several instruments will be done fast
and efficient.
The
test cables are as standard connected to the front panel of the
instrument.
Another possibility is to order the DB231 LCR Component Capacitor
Tester in the version MCR in order
to have the test cables connected to the rear panel only.
Optional protection box
PB10. For further protecting of the instrument against charged
capacitors.
|
| Measured
Parameters: |
C,
L, R, Z (serial or parallel) tan¶,
ESR, Rs, Rp, L/Q, R-X, Z-q
(deg or rad) |
| Measuring
Frequencies: |
1MHz,
100k, 10k and 1kHz with multiple frequency facility |
| Measuring
Voltages:
|
1
V RMS up to 10mF at 1kHz |
| 1
V RMS up to 1mF
at 10kHz |
| 1
V RMS up to 100nF at 100kHz |
| 1
V RMS up to 10nF at 1MHz |
|
Above:
(linearly decreasing with the impedance).
Programmable in 0.1V steps (maximum
1,5V RMS)
|
| |
|
1kHz |
10kHz |
100kHz |
1MHz |
| Measuring
Speed
|
From
trig to end of measurement*: |
20ms
|
20ms |
6ms |
6ms |
| From
trig to data ready *: |
28ms
|
28ms |
14ms |
14ms |
| Additional
time per meas. by average |
16ms
|
16ms |
2ms |
2ms |
|
*)
allowing 3ms contact bouncing or 1 range change
Multiple measurements (average): The sum of each measurement
(from trig to end of measurement) + 8ms for calculation time
|
| Measuring
Cables: |
1m
(39,3 inch) from front panel to fixture (Cables supplied)
|
| Input
Protection: |
2
Joule up to 1kV or 4mF
charged 1000V
|
| Bias
Voltage internal: |
Up
to ±3,0VDC
on generator terminal, set in 0,1V steps (internally generated)
|
| Frequency |
Accuracy
±1
digit |
Average ³ |
| Capacitance
|
1kHz |
10kHz
|
Capacitance
|
Tan
d
|
|
1pF-39pF
|
0,1pF
- 3,9pF |
0.2
pF |
±,0010
|
| 40pF-3,9mF |
4pF
- 3,9mF |
0,05%*
|
±,0002
|
| 4mF-399mF |
4mF
- 39mF |
0,1% |
±
,0007
|
| 400mF-1mF |
40mF
- 400mF |
1% |
±
,0020
|
|
100kHz
|
1MHz
|
|
|
| ,03pF-,9pF |
,01pF
- 3,9pF |
0,1pF |
±
,0010 |
| 1pF-,9mF |
4pF
- 0,9nF |
0,05%** |
±
,0002 |
| |
1nF
- 9,9nF |
0,1% |
±
,0007 |
|
1mF-9mF
|
10nF-
29nF |
0,2% |
±
,0010 |
| 10mF-40mF |
30nF
- 99nF |
1% |
±
,0020 |
*Accuracy
± 0,2pF
**Accuracy ± 2pF.
The above
specifications require
a stable jig with capacitance lower than
30pF
|
| Inductance |
1
kHz |
10kHz |
100kHz |
Accuracy |
1MHz |
Accuracy |
| |
10mH-100H |
1mH-10H |
0,1mH-1H |
1
parameter
0.1%
2 parameter
±(0.1%+0.05xQ) |
0,2mH-0,1H |
1
parameter
0.1%
2 parameter
±(0.2%+005xQ) |
|
Resistance
|
0,4Ω-40Ω |
0.4Ω-40Ω |
0.4Ω-40Ω |
0.1% |
0.4Ω-40Ω |
0.1% |
| |
40Ω-4MΩ |
40Ω-4MΩ |
40Ω-1MΩ |
0.05% |
40Ω-100kΩ |
0.05% |
| |
|
|
|
|
100kΩ-400kΩ |
0.5% |
The above
specifications are valid for measurements with constant voltage
|
| Bin
Sorting
Up to 12 limits for 1st parameter
and 4 limits for 2nd parameter
by opto-couplers |
| Interfaces:
|
Rear
panel: |
IEEE
488 (GPIB) and RS232C
|
| Control: |
Measure end, data ready, trig ready, fault and status
|
| Trig
input: |
DC,
AC and contact closure
|
| Front
panel: |
PC
card for set-ups, save and loading
|
| Environment:
|
Ambient
temperature
|
10-30
degrees Celsius
|
|
Warm-up
time:
|
Minimum
30 minutes |
| Power: |
90-130 and 200-260 V AC, 50-60 Hz,
|
| Calibration
interval: |
Minimum: |
Every
12 months
|
|
|
Dimensions:
| |
Mainframe: |
Export
Packing Europe |
Export
Packing Overseas |
| Height |
140mm
or 5,5 inch |
30cm
or 11.7 inch |
32cm or 12.8 inch |
| Width |
438mm
or 17,2 inch |
51cm
or 20 inch |
52cm or 20.4 inch |
| Depth |
360mm
or 14,2 inch |
56cm
or 22 inch |
55cm or 21.6 inch |
| Weight |
Total
16kg or 36 lb. |
20kg
or 45 lb |