  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  

DO2003 ANEMOMETER VELOCITY METER


DO2003 Anemometer Velocity Humidity Temperature Meter is a portable instrument, data logger designed to be used in the fields of air-conditioning, heating, ventilation, environmental comfort, both for industrial and residential application by means of a complete probes series. 
It measures:

  • Air speed and flow rate inside pipeline with hot-wire probes, vane probes or Pitot tube probes

  • relative humidity and temperature with combined probes

  • differential pressure up to 2000 mbar and barometric pressure

  • temperature with immersion, pointed or contact probes.

  • This datalogger stores up to 12.000 readings which can be displayed or downloaded to a PC connected to the instrument through RS232C serial port



DO2003 Anemometer Velocity Humidity Temperature Meter

Display: 
3½ digit, dual LCD, figure height 12,5 mm. 
Unit of measure and other additional information
are supplied with a led series.
No. 2 inputs: 
input A for air speed and pressure probes, 
input B only for combined temperature humidity probes.
Storage capacity: 12.000 readings.
Storage interval and printing can be configured between
one second and 1 hour.
Working temperature: -5°C..50°C,
Relative humidity 0-90% RH. not condensing.
Storage temperature: -20°C..+60°C.
Power supply: four 1.5V alkaline AA batteries, 
Operating time with alkaline batteries 100 hours approx.
9 pole SUB D male RS232C serial output.
Baud rate from 300 to 38400 baud.
Dimensions and weight: 72x210x40 mm - 320gr.

PROBES FOR DO2003 EQUIPPED WITH SICRAM MODULE
Probes for air speed measurement
HOT AIR PROBES
VANE PROBES
PITOT TUBE PROBES
Pt100 sensor temperature probes



TP472I Wire Pt100 immersion probe. Tube Ø 3 mm, length 300 mm. 4 wire cable, 2 m long.
Working range: -196°C…+500°C.
Accuracy: ±0.2°C (-196°C…+350°C) / ±0.4°C (+350°C…+500°C).

TP473P Wire Pt100 pointed probe. Tube Ø 4 mm, length 150 mm. 4 wire cable, 2 m long.
Working range: -100°C…+400°C.
Accuracy: ±0.2°C (-100°C…+350°C) / ±0.4°C (+350°C…+400°C).

TP474C Thin film Pt100 contact probe. Tube Ø 4 mm, length 230 mm, contact surface made of silver Ø 5 mm. 4 wire cable, 2 m long.
Working range: -50°C…+400°C.
Accuracy: ±0.2°C (-50°C…+350°C) / ±0.4°C (+350°C…+400°C).

Relative humidity and temperature probes

HP472AC %RH and temperature combined probe, dimensions Ø 26x170 mm. Connecting cable: 2 m long. Working range: -20°C…+80°C, 5…98% RH.
%RH accuracy: ±2% °C accuracy: ±0.25°C.

HP572AC %RH and K thermocouple temperature combined probe
Dimensions Ø 26x170 mm. 
Connecting cable: 2 m long.
Working range: -20°C…+80°C, 5…98% RH.
%RH accuracy: ±2% °C accuracy: ±0.5°C.

HP473AC %RH and temperature combined probe. Handle Ø 26x130 mm, probe Ø 14x110 mm. Connecting cable: 2 m long
Working range -20°C…80°C, 5…98% RH.
%RH accuracy: ±2% °C accuracy: ±0.25°C.

HP474AC %RH and temperature combined probe. Handle Ø 26x130 mm, probe Ø 14x210 mm. Connecting cable: 2 m long .
Working range: -40°C…+150°C, 5…98% RH.
%RH accuracy: ±2% °C accuracy:±0.25°C

HP475AC %RH and temperature combined probe. Handle Ø 26x110 mm. Steel probe Ø12x560 mm. Terminal tip Ø 13,5x75 mm. 
Connecting cable: 2 m long.
Working range -40°C…+150°C, 5…98% RH.
%RH accuracy: ±2% °C accuracy: ±0.30°C

HP477DC %RH and temperature sword combined probe, handle Ø 26x110 mm. Probe 18x4 mm, length: 520 mm. Connecting cable: 2 m long.
Working range -40°C…+150°C, 5…98% RH.
%RH accuracy: ±2% °C accuracy: ±0.30°C

Pressure probes

PP472 Probe for measuring barometric pressure.
Working range: 600 … 1100mbar Resolution: 0.1mbar
Accuracy @ 20°C: ±0.3mbar Temperature range: -10 … +60°C

PP473 S1…S8 Differential pressure probes
Working range: S1=f.s.10mbar, S2=f.s.20mbar, S3=f.s.50mbar,
                            S4=f.s.100mbar, S5=f.s.200mbar,  
                            S6=f.s.500mbar, S7=f.s.1bar,
                            S8=f.s.2bar
Maximum overpressure: 
S1,S2,S3=200mbar, S4=300mbar,
S5,S6=1bar, S7=3bar, S8=6bar
Accuracy @ 25°C: 
±0.5%f.s. (10, 20, 50mbar)
±0.25%f.s. (100mbar)
±0.12% f.s. (200, 500, 1000, 2000mbar)
Temperature range: -10 … +60°C
Fluid in contact with the membrane: non-corrosive dry gas or air
Connection tube Ø 5mm