DIGITAL ILLUMINANCE
PAR IRRADIANCE RADIOMETER |
|
|
|
HD2102 Digital Illuminance Luminance PAR Irradiance Photo Radiometer |
|
|
HD2102.1K Digital
illuminance, luminance, PAR, irradiance meter. Storage of maximum, minimum,
average value and the integral Q(t), RS232 C output for data transfer in
real time to a PC or printer. Functions: REL, HOLD and auto power off which
can be disabled, IP 67 protection degree.
HD2102.2K Digital illuminance, luminance, PAR, irradiance meter.
Datalogger. Storage of maximum, minimum, average value and the integral Q(t), it can
store up to 80.000 samples. RS232 C/ USB output for data transfer in real
time to a PC or printer. Functions: REL, HOLD and auto power off which can
be disabled, IP 67 protection degree.
Measuring unit lux - fcd - lux/s - cd/s - W/m²
- μW/cm² - J/m²
- μJ/cm² -
μmol(m².s) -
μmol/m² - cd/m²
|
 |
The HD2102.2
instrument is a datalogger.
It stores up to 38,000 samples which can be transferred from the instrument
connected to a PC via the
multi-standard RS232C serial port and USB 2.0.
The storing interval, printing, and baud rate can be
configured using the menu.
The HD2102.1 and HD2102.2 models are fitted with an RS232C serial port and
can transfer the acquired measurements in real time to a PC or to a portable
printer.
The Max, Min and Avg function calculate the
maximum, minimum or average values.
Other functions include: the relative measurement
REL, the HOLD function, and the automatic
turning off that can also be disabled.
|
|
|
|
|
ORDER CODES
HD2102.1K: The kit is composed of the instrument HD2102.1,
connection cable for serial output HD2110CSNM, 4 1.5V alkaline batteries, operating
manual, case and DeltaLog9 software. The probes must be ordered separately.
HD2102.2K: The kit is composed of the HD2102.2 datalogger,
connection cable HD2101/USB, 4 1.5V alkaline batteries, operating manual, case and
DeltaLog9 software. The probes must be ordered separately. HD2110CSNM: 8-pole connection cable MiniDin - Sub D 9-pole
female for RS232C. HD2101/USB: Connection cable USB 2.0 connector type A -
8-pole MiniDin. DeltaLog9: Software for download and management of the data on PC
using Windows 98 to XP operating systems. AF209.60: Stabilized power supply at 230Vac/9Vdc-300mA mains
voltage. S’print-BT: On request, portable, serial input, 24 column
thermal printer, 58mm paper width.
|
Probes complete with
SICRAM module LP 471 PHOT: Photometric probe for ILLUMINANCE measurement
complete with SICRAM module, spectral response in agreement with standard
photopic vision, diffuser for cosine correction. Measurement range:
0.01 lux…200 x 10³ lux. LP 471 LUM 2: Photometric probe for LUMINANCE measurement
complete with SICRAM module, spectral response in agreement with standard photopic vision, vision angle 2°. Measurement range: 0.1 cd/m²…2000
x 10³
cd/m². LP 471 PAR: Quantum radiometric probe for the measurement of
the photon flow across the chlorophyll range PAR (Photosynthetically Active
Radiation 400nm…700nm) complete with SICRAM, measurement in μmol/m²s,
diffuser
for cosine correction. Measurement range:
0.01μmol/m²s…10
x 10³μmol/m²s. LP 471 RAD: Radiometric probe for IRRADIANCE measurement
complete with SICRAM module; in the 400nm…1050nm spectral range, diffuser for
cosine correction. Measurement range: 0.1x10-³W/m² …2000 W/m².
LP 471 UVA: Radiometric probe for IRRADIANCE measurement
complete with SICRAM module; in the 315nm…400nm, peak 360nm, UVA spectral range, quartz diffuser for cosine correction.
Measurement range:
0.1 x 10-3W/m²…2000 W/m². LP 471 UVB: Radiometric probe for IRRADIANCE measurement
complete with SICRAM module, in the 280nm…315nm, peak 305nm, UVB spectral range, quartz diffuser for cosine correction.
Measurement range:
0.1x10-³W/m²…2000 W/m². LP 471 UVC: Radiometric probe for IRRADIANCE measurement
complete with SICRAM module, in the 220nm…280nm, peak 260nm, UVC spectral range, quartz diffuser for cosine correction. Measurement range: 0.1x 10-³W/m²…2000 W/m².
LP 471 ERY: Radiometric probe for EFFECTIVE TOTAL IRRADIANCE
(Weff /m²) according to the UV action curve (CEI EN 60335-2-27) complete with SICRAM module. Spectral range: 250 nm…400 nm, quartz diffuser for cosine correction. Measurement range: 0.1x 10-³Weff /m² … 2000 Weff
/m². LP BL: Base with leveling device.
|
|
|