All ProductsAnalyticalAnalyzersCalibratorsHumidityData LoggersLight MetersMeasurement

 

MultimetersOhmmetersPressureStandardsTemperatureTransmitters

DIGITAL ILLUMINANCE PAR IRRADIANCE RADIOMETER 
HD2302 Digital Photo Radiometer Illuminance PAR Irradiance Meter

HD2302.0K Device for measuring illuminance, luminance, PAR, irradiance which use probes with SICRAM module. Storage of maximum, minimum, average value.
Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.

The HD2302.0 is a portable instrument
with a large LCD display.
It measures illuminance, luminance, PAR and
irradiance (across VIS-NIR, UVA, UVB and
UVC spectral regions or measurement of irradiance effective according to the UV action curve).

The probes are fitted with the SICRAM automatic detection module: in addition to detection,
the unit of measurement selection is also
automatic.
The factory calibration settings are already
memorized inside the instruments.

The Max, Min and Avg function calculate the maximum, minimum or average values.
Other functions include: the relative measurement REL, the HOLD function, and the automatic
turning off that can also be disabled.

INSTRUMENT TECHNICAL CHARACTERISTICS

Instrument
Dimensions
(Length x Width x Height) 140x88x38mm
Weight 160g (complete with batteries)
Materials ABS
Display 2x41⁄2 digits plus symbols - 52x42mm
Visible area: 52x42mm
Operating conditions
Operating temperature -5…50°C
Warehouse temperature -25…65°C
Working relative humidity 0…90%RH without condensation
Protection degree IP67
Power
Batteries 3 1.5V type AA batteries
Autonomy 200 hours with 1800mAh alkaline batteries
Power absorbed with instrument off 20μA
Measuring unit lux - fcd - μmol/m2.s - cd/m2 - W/m2 - μW/cm2
Connections
Input module for the probes 8-pole male DIN45326 connector

ORDER CODES
HD2302.0K: The kit is composed of the instrument HD2302.0, 3 1.5V alkaline batteries,
operating manual, case. The probes must be ordered separately.
Probes complete with SICRAM module
LP 471 PHOT: Photometric probe for ILLUMINANCE measurement complete
with SICRAM module, spectral response in agreement with standard photopic vision,
diffuser for cosine correction. Measurement range:0.01 lux…200 x 10
³ lux.
LP 471 LUM 2: Photometric probe for LUMINANCE measurement complete with
SICRAM module, spectral response in agreement with standard photopic vision,
vision angle 2°. Measurement range: 0.1 cd/m2…2000 x 10
³  cd/m².
LP 471 PAR: Quantum radiometric probe for the measurement of the photon flow
across the chlorophyll range PAR (Photosynthetically Active Radiation
400nm…700nm) complete with SICRAM, measurement in μmol/m
²s, diffuser
for cosine correction. Measurement range: 0.01μmol/m
²s…10 x 10³ μmol/m²s.
LP 471 RAD: Radiometric probe for IRRADIANCE measurement complete with
SICRAM module; in the 400nm…1050nm spectral range, diffuser for cosine
correction. Measurement range: 0.1x 10-
³ W/m² …2000 W/m².
LP 471 UVA: Radiometric probe for IRRADIANCE measurement complete with
SICRAM module; in the 315nm…400nm, peak 360nm, UVA spectral range,
quartz diffuser for cosine correction. Measurement range: 0.1x 10-
³ W/m²…2000 W/m².
LP 471 UVB: Radiometric probe for IRRADIANCE measurement complete with
SICRAM module, in the 280nm…315nm, peak 305nm, UVB spectral range,
quartz diffuser for cosine correction. Measurement range: 0.1x 10-
³ W/m²…2000 W/m².
LP 471 UVC: Radiometric probe for IRRADIANCE measurement complete with
SICRAM module, in the 220nm…280nm, peak 260nm, UVC spectral range,
quartz diffuser for cosine correction. Measurement range: 0.1x 10-
³ W/m²…2000 W/m².
LP 471 ERY: Radiometric probe for TOTAL EFFECTIVE IRRADIANCE (Weff/m
²)
according to the UV action curve (CEI EN 60335-2-27) complete with
SICRAM module. Spectral range: 250 nm…400 nm, quartz diffuser for
cosine correction. Measurement range: 0.1x 10-
³ Weff /m² … 2000 Weff /m².
LP BL: Base with leveling device for the probes.

 

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [Top] [Distribution] [Contact Us]