  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

HD32.8. TEMPERATURE DATALOGGER 16 INPUTS


HD32.8.8 Data Logger Temperature with display. 8 inputs thermocouple types K, J, T, N, R, S, B, E.
HD32.8.16 Data Logger Temperature with display. 16 inputs thermocouple types K, J, T, N, R, S, B, E.
The HD32.8.8 and HD32.8.16 instruments are rugged data loggers.
The former has 8 inputs, the latter has 16 inputs. They work with thermocouple probes type K, J, T, N, R, S, B and E with miniature connector.

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
  • Flash memory, organized in 64 blocks, for a total capacity of 800,000 recordings divided among the existing inputs. The recording can be handled in two ways:
    - when the available memory is full, the collected data are overwritten
    starting from the oldest ones (circular memory),
    - the recording stops when the available memory is full.

  • DeltaLog9 software, for data download and processing.

  • LCD backlit graphic display 128x64 pixel.

  • Instrument setup through the keyboard; no connection required to the PC.

  • Security password for keyboard locking.

  • Power supply: 4 1.5V alkaline C-BABY type batteries, external power supply
    12VDC-1A or PC USB port.

  • Consumption @6VDC:
    <60μA when the instrument is off
    <60μA in sleep mode with all probes connected
    <40mA during data logging with all probes connected

  • Use of the HD32.8.8 and HD32.8.16 data loggers: in the field for complex machine or equipment multi measurements, machine testing, pharmaceutical and food industry, oven mapping,
    air conditioning units, etc.

Number of inputs 8 for the HD32.8.8
16 for the HD32.8.16
Connection Miniature female socket for thermocouple
Instrument accuracy and
measurement range
Tc: K -200 … +1,370°C / ±0.1°C up to 600°C ±0.2°C over 600°C
Tc: J -100 … +750°C / ±0.1°C up to 400°C ±0.2°C over 400°C
Tc: T -200 … +400°C / ±0.1°C
Tc: N -200 … +1,300°C / ±0.1°C up to 600°C ±0.2°C over 600°C
Tc: R +200 … +1,480°C / ±0.3°C
Tc: S +200 … +1,480°C / ±0.3°C
Tc: B +200 … +1,800°C / ±0.4°C
Tc: E -200 … +750°C / ±0.1°C up to 300°C ±0.2°C over 300°C
Resolution 0.05°C in the range ±199.95°C
0.1°C in the remaining range
Temperature drift @20°C 0.02%/°C
Drift after 1 year 0.1°C/year
Internal watch accuracy 1min/month max deviation
Unit of measurement °C, °F, °K
Display LCD backlit graphic display 128x64 pixel.
Keyboard 15 keys; the instruments can be configured
without a PC.
Keyboard locking function with password.
Memory Divided into 64 blocks.
Storage capacity Up to 800,000 recordings divided
among the existing inputs; for example
with one probe connected, 800,000
recordings; with 8 probes connected,
96,000 recordings each.
Security of stored data Unlimited.
Power supply 4 1.5V alkaline C-BABY type batteries
External power supply 12VDC-1A. Connector,
external
Power absorbed @6VDC: <60μA when the instrument is off
<60μA in sleep mode with all probes
connected
<40mA during data logging with all
probes connected
Autonomy 200 hours with 7800mAh alkaline batteries,
with all probes connected
Data download RS232C from 1200 to 38400 baud, galvanically
isolated. Sub D 9-pole male
connector.
USB 1.1 – 2.0 galvanically isolated.
Operating temperature -5 … 50°C
Working relative humidity 0 … 90% RH without condensation
Protection degree IP64