  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

TEMPERATURE REGULATOR CONTROLLER FOR Pt100 PROBES


HD 4045 Digital LED ON/OFF temperature regulator 48x78. Pt100 sensor. Range -50°C…+800°C. Resolution 1°C. Hysteresis 1...20°C. Relay 5A/220V resistive. Power supply 24Vac/dc, on request 110…230Vac/dc. Without probe.



Temperature regulator, controller
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

This is a temperature regulator, controller with relay ON/OFF output. 

The setting of the intervention temperature (set point) is carried out by pressing the button
on the left of the front panel of the instrument and turning the knob on the right until the
temperature at which the relay contact is to open is shown on the display. Intervention
hysteresis may be adjusted with a trimmer at the rear of the instrument. 

The temperature sensor is a PT 100. 
If it is connected with 2 wires with a section of 1 mm2 , a reading in excess of 0.06°C/m is obtained.
In order to cut down error a three-wire connection is advised, with the third wire connected to terminal 2. The thermostat may be used either for heating or for cooling, simply by moving the jumper at the rear of the instrument. 
When the jumper is in HEATING position, the relay is energized if the probe temperature is lower than the set temperature; when the jumper is in COOLING position, the relay is energized if the probe temperature is higher than the set temperature.

TECHNICAL DATA
  • Using range: -50C ... +800°C

  • Resolution: 1 °C

  • Display: LED, height 12.7 mm

  • Precision: 1°C ± 0.3% of reading + probe tolerance

  • PT 100 Connection: with two or three wires

 

  • Power supply: 24V/3VA

  • Outputs: relay contact 5A/22OVAC. resistive

  • Hysteresis: 0,1 ... 5°C

  • Working temperature: -5 ... +45°C

  • Dimensions: front panel 78 x 48 mm instrument body 72 x 42 x 78 mm

 