  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

K THERMOCOUPLE SENSOR THERMOMETERS


The HD 9016 Digital Thermometer has the following built-in functions: Automatic cut-out after 8 minutes: AUTO POWER OFF Automatic change of scale: AUTORANGE. Relative measurements: REL.
Stores and displays the maximum and minimum temperature value at each input: REC, DATA CALL. Calculates the difference between the two inputs: A-B. Acoustic signal (beep) after pressing a key. 
Low battery signal (beep) every 30 seconds.

It is available with a large range of type K thermocouple probes in different shapes and configurations for many different applications.



Digital Thermometer
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Measuring range with thermocouples:

K: -200°C...+1370°C (CHROMEL - ALUMEL)
J: -100°C...+750°C (IRON - CONSTANTAN)
T: -200°C...+350°C (COPPER - CONSTANTAN)
E: -200°C...+750°C (CHROMEL - CONSTANTAN)
R: +200°C...+1480°C (PLATINUM - PLATINUM 13% RHODIUM)
S: +200°C...+1480°C (PLATINUM - PLATINUM 10% RHODIUM)
B: +200°C...+1800°C (PLATINUM 6% RHODIUM - PLATINUM 30% RHODIUM)

TECHNICAL DATA

Inputs: 2
INSTRUMENT RANGE:
Thermocouple K: (-200°C...+1370°C)    
(-328°F +1999°F)
Thermocouple J: ( -100°C...+750°C)
(-148°C...+1382°F)
Thermocouple T: (-200°C...+350°C)
(-328°F...+662°F)
Thermocouple E: (-200°C...+750°C)     
(-328°F +1382°F)
Thermocouple R: (+200°C...+1480°C)
(+392°F...+1999°F)
Thermocouple S: (+200°C...+1480°C)
(+392°F...+1999°F)
Thermocouple B: (+200°C...+1800°C)
(+392°F...+1999°F)
Probe connections: 2 miniature thermocouple sockets K, compensated cold junction.
Resolution: +199.9°C (+199.9°F) 0.1°C
(0.1°F) +200°C (+200°F) 1°C (1°F)
Precision (instrument alone) with temperature from 18°C to 25°C: -20O°C....-50°C 0.4°C,
 -50°C....+200°C 0.2°C, 
+200°C.... +800°C 2°C
Influence of temperature in the instrument work range - 5°C...+18°C: +25°C...+50°C
-200°C....-50°C: 0.4°C +0.01 °C/°C,
 -50°C...+200°C: 0.2°C +0.01°C/°C,
+200°C... +800°C:

VC Conversion frequency: 
1 second
Instrument working temperature: 0...+50°C
Relative humidity: 0...90% R.H.
Instrument functions:
 Automatic change of scale, HOLD, automatic cut-out, MAX/MIN storage, relative measurements, difference between inputs, arrangement for serial output RS232C, selection of thermocouple type.
Serial output: RS 232 C, unidirectional, data transmission speed 300 baud. Connection by means of a connecting cable AD RS 232 C from SUB D female 9-pole to SUB D female 25-pole. Transmission of the displayed value at a fixed rate every 10 seconds.
Display: LCD 3 1/2 digit figure height 12.5 mm, symbols HOLD, RCD, REL, MAX, MIN, °C, °F, A, B, A-B.
Power supply: 9V battery IEC 6LF22.
Battery life: approximately 100 hours, alkaline battery.
Instrument weight: 280 gr.
Dimensions: 215x73x38 mm.