AA 150 F |
AA 330 F |
AA 500 F |
AA 660 F |
AA 1000 F |
AA 2000 F |
| Nominal Output
voltage |
100, 115, 200,
230 V ms (selectable for 4 Steps) |
| Continuously-variable
output voltage range |
1% to 120% of
each nominal output voltage |
- Rated output power
- A. Power resistive load
|
150 W |
330 W |
500 W |
660 W |
1000
W |
2000 W |
- Rated output power
- B. Capacitor-input load
|
180
VA |
400
VA |
660
VA |
800
VA |
1,2
kVA |
2,4 kVA |
- Output voltage regulation
- Regulation against input voltage
|
±0,1% or
better (against ±15% change of input voltage) |
- Output voltage regulation
- Regulation against load change
|
±1% or better
(against 0 to 100% change of load current) |
- Response (recovery)
- against transient
|
100 µs or
faster (against 0 to 100% change of load current) |
| Peak output
current |
2,5 times peak
value of pure-resistance load current (rms-value) for
capacitance-input load |
| Output
frequency |
50, 60, 400 Hz
and variable for ±10% of each of these nominal frequencies |
| Frequency
accuracy |
Quartz Lock
Mode: Output frequency x 5 x 100 -5; Variable Mode: Output frequency
x 10 -3 |
| Distortion
factor (THD) % |
0,5% or less
(with pure-resistive load, rated output) |
| Frequency characteristics |
Within ±0,2
dB (for 45 - 440 Hz, with rated output) |
- Indicating meters:
- Output voltmeter class 2.5
|
150 V / 300 V
full scale, rectifier type, JIS |
- Indicating meters:
- Output ammeter class 2.5
|
2,5 A FS |
5 A FS |
7,5 A FS |
10 A FS |
15 A FS |
30 A FS |
| Input line voltage |
115/230V±15%
50/60 Hz single phase AC |
| Weight / kg (net) |
18,5
|
30
|
36
|
46
|
70
|
110
|