1) Circuit System
linear type
2) Cooling
Forced Air Cooling (not EPJ-3505)
3) Rating
Constant Voltage
Line regulation: 0,005% + 3 mV
(to Input Voltage ± 10%)
Load regulation: 0,005% + 3 mV
(to 0 ~ 100% Load)
(Measured at the sensing terminal)
Ripple: Within 1 mV (10
Hz ~ 1MHz rms) for models
which output voltage is less than 80 V.
Within 3 mV (10 Hz ~ 1 MHz rms) for models
of which output voltage is less than 800 V.
Transient Response: 50 µs typical
(0 ~ 100% Load)
100 µs typical (100 ~ 0% Load)
The time required for the output voltage to
recover to a value within the rated voltage
0,005% + 3 mV at the time of 0 ~ 100%
fluctuation of output current.
Temperature-
Coefficient: 50 ppm/ °C typical
Constant Current
Line regulation: 0,05% + 2 mA
(to input voltage ± 10%)
Load regulation: 0,05% + 5 mA
(to 0 ~ 100% Load)
Ripple: (Maximum operating current
value + 10)/Z in (mA)
Z denotes Load impedance at 50 Hz
Temperature-
Coefficient: 100 ppm/ °C typical
4) GP-IB Interface (Optional)
System: IEEE488
Resolution: 16 bit
Port: 24 way amphenol
Programming: Voltage and Current
Function Indicators: Listen, Talk, SQR
5) 19" Rack Mounting
For power supplies of portable
type, various accessories for rack-mounting are provided (RMH).
|
2. Specification
Over voltage Protection
(OVP)
Over current Protection (OCP)
Over voltage prevention can
be set at a range from 1 V to full scale as desired observing the
front output voltmeter.
The output is turned off by SCR (only EPJ-3510/EPJ-3520),
simultaneously input power is also turned off. Over current
prevention can be set at a range from 0 to full scale as desired.
Over voltage/Over current can be set by PRESET-switch in a state of
no load and no output voltage.
Response time is 50 µs (typical).
Over temperature
Protection
(OTP)
When the temperature of transformer
and semiconductor becomes in a state of abnormally due to stoppage
of cooling fan, malfunction of power supply etc., the input power its
turned off.
Detectable temperature: 100°C for
transistor and heatsink
130°C for transformer
Highly accurate programming for
output voltage and current by external voltage
Remote programming capability of
the output voltage and current is provided with accuracy approximately
0,1% by external voltage (0 – 10 V) since OP AMP
precisely adjust circuit.
Features
(VC) Adjustment of output voltage
(10 revolution potentiometer)
(CC) Adjustment of output current (10 revolution potentiometer)
(OVP) resets output when voltage exceeds preset voltage.
(PRESET) Output current can b e preset while output-load is set to
off.
CV/CC – status indicating LED
Alarm – status indicating LED
Remote sensing terminal (except (EPJ-8001)
Master – Slave – Control (except EPJ-8001)
CV/CC – Remote Control by resistance and voltage signal
GP-IB Interface by build in type (Option)
GB-IB-Interface EPJ-IF
The integrated GP-IB Interface
corresponds to a 16 Bit analog/digital transformer (resolving
power 1/65535) equipped with four Input or Output channels. Input
Voltage und Current can adjusted and immediately read back in each
case. The programmer has a list as well a talker function.
|