METRAHit 29S
True RMS Digital Multimeter.
METRAHit 29S 5¾
place, precision, digital TRMS multimeter, power meter and power
disturbance measuring instrument, CAT.IV
Precision multimeter, power meter and power disturbance measuring
instrument with integrated memory for universal use in the field of
energy electronics, and for high bandwidth electronics applications
from 16 Hz to 100 kHz, TRMS AC and TRMSAC and DC,
CAT IV
|
TRMS Multimeter Power Meter
|
| Our
Price: |
Contact us for
pricing |
| Phone:
|
253-927-6186
866-318-6186 |
| Fax:
|
253-927-6189 |
| email:
|
sales@hotektech.com |
|
|
|
|
|
-
Rugged
digital multimeter, ± 310,000 digits,
-
With
triple
display
-
Automatic
blocking system (ABS)
-
IR
interface, V DC, VAC/DC, V AC, mA
DC, mAAC/DC,
to max. 10 AAC/DC, Ohm, °C
(Pt100/Pt1000, type J and K thermocouples), W, VA, Var, Wh, Vah,
peak load profile, power disturbance measurements, power disturbance
recording
-
Continuity
and diode testing
-
MIN-MAX
measurement value storage, DATA hold
-
Minimal
inherent deviation± (0.02% + 10 digits for V DC )
-
With
cable set, protective rubber cover and DKD calibration certificate
-
600 V
CAT.IV or 1000 V CAT.III per IEC 61010-1
|
|
Applications
|
|
|
METRAHit 29S
multimeters are high performance precision instruments for the lab,
service and training. With a display range of 300,000 digits as well
high level accuracy and long-term stability, they fulfill all
calibration and R&D laboratory demands.
Battery operation allows
for on-site precision servicing and calibration.
|
|
Features
|
Convenient Triple
Display
The current measurement value, as well as
two other values, are updated and displayed, e.g. minimum and maximum
value.
The usual switching back and forth between display values is no longer
necessary.
Display resolution for the main display value can be varied from 4¾
places for AC to 5¾ places for DC METRAHit29S: from 2¾
to 5¾ places). The measurement rate, adjustable from 1 ms to 0.5 s,
allows for high-speed recorder, precision data logger and mean value
recorder functions with the help of
METRAwin10/METRAHit (optional PC software).
High Resolution and
Precision
5¾ places, or 309,999 digits,
allow for cost effective calibration of tested devices and components,
as well as precise reference measurements.
Effective Value for Distorted Waveforms
The implemented measurement process provides for effective value
measurement (TRMS) independent of the waveform up to 100 kHz.
Additional
Functions
Continuity testing with acoustic signal,
event counting (number of events and event durations),
counts zero
crossings, stopwatch, data comparison and wide-range capacitance
measurement.
The integrated temperature measurement function allows for the
connection of thermocouples and platinum resistance thermometers.
Overload
Protection
The instrument is protected from overload in
the voltage range.
Acoustic signaling occurs if measuring range
limits are exceeded.
The FUSE display indicates a defective fuse in the current range.
Calibration
METRAHit 29S multimeters are shipped
with calibration certificate.
They can be automatically
calibrated with the CS92E calibration system via the RS232 data
interface.
Infrared Measurement Data Transmission
These devices include a serial, duplex data
interface for remote control and measurement value transmission via
infrared light.
|
Automatic Blocking System (ABS) *
Automatic blocking of connector sockets prevents incorrect connection
of measurement cables, and selection of incorrect measuring
quantities. Thus hazards for the operator, the instrument and the
system are substantially reduced, and in many cases entirely
eliminated.
Automatic
Measurement Value Storage *
The DATA HOLD function allows for storage of
the digitally displayed measurement value.
A patented process assures
that the actual measurement value, and not random values,
are stored
when rapid measurement magnitude changes occur.
The stored measurement value appears at the digital display.
Protected by patent
Sampling Rate
The sampling rate determines the time interval after which the
respective measurement value is transmitted to the interface, or saved
to measurement value memory.
Depending upon the measured quantity, sampling rates can be set in
steps of 1, 2 or 5
from 0.05 s to 10 min.
Memory Mode
The METRAHit 29S multimeter is equipped with a 128 kB measurement value memory
which is synchronized with a quartz movement, and which has room for
13,000 to 60,000 measurement values depending upon configuration.
Data
can be stored to intermediate memory or uploaded directly to a
PC.
The system records data relative to real-time which allows for use as
a real time data
logger.
Depending upon the measured quantity, sampling rates can be
adjusted in steps of 1, 2 or 5 within a range of 0.5 ms to 10 min.
Selected measurement values can also be stored to memory by pressing a
key.
The contents of the memory can be read out with the help of a PC which
has been connected to the multimeter via the METRAHitBD232 IR
adapter, and with METRAwin10/METRAHit analysis software.
|
Power Measurement
The METRAHit29S is a
compact high performance measurement instrument for direct and
alternating current for single and three-phase current measurements.
The current path can be connected directly, or with a clip-on current
transformer.
If a current transformer is connected to the multimeter (mA or A
input), all current and power displays appear with the correct value
in accordance with the selected transformation ratio.
The utilized
current transformer must have a transformation ratio of 1000:1 or
10,000:1.
Universal power measuring functions include the measurement
of active, reactive, and apparent power, as well as power factor and
energy . Furthermore, mean and peak values (e.g. a 15 minute max.
value) can be measured during a predefined period of time.
Type WZ12D, Z3511, Z3512 and Z3514 current clips are suitable for use
with the instrument.
Power Disturbance
Recording
The METRAHit 29S multimeter is capable of continuously recording line voltage
and power disturbances.
The following power disturbances can be
acquired: violation of predetermined limit values, power failure and
positive or negative pulses.
Each of these events is stored to memory
and can be queried at a later point in time.
The type of event, the
time of its occurrence and its duration (except for pulses) are
displayed.
If memory mode is deactivated, approximately 250 events can be stored
to volatile memory and read out at the display.
These data remain in storage until the instrument is switched to a
different operating mode.
If memory mode is activated, the events are recorded at the instrument
as a non-compressed data file which is uploaded to a PC at a later
point in time.
|