All ProductsAnalyticalAnalyzersCalibratorsHumidityData LoggersLight MetersMeasurement

 

MultimetersOhmmetersPressureStandardsTemperatureTransmitters

DIGITAL TRMS SYSTEM MULTIMETER 

METRAHIT OUTDOOR 4˝ Place TRMS System Multimeter 

 

METRAHit OUTDOOR 4˝ Place TRMS System Multimeter.
The OUTDOOR multimeter has been specially designed and manufactured to meet the challenges faced by engineers and technicians in adverse environments.
It's extremely rugged, impact-resistant, water-proof and dust-proof, and is resistant to extreme temperatures.
Digital Hand-Held Multimeter with TRMS Measurement VAC RMS, VAC+DC TRMS, VDC, Hz (V),
Hz (A), Ω, V , °C/°F (TC).
4˝-place display (11,999 digits), with display illumination. 23 multimeter functions.
Additional “low-resistance” (1 MΩ) alternating voltage measurement

  • Special rugged design with shock and impact resistant housing, and additional rubber holster
  • Special "sand" color
  • Dust-proof: IP 6x
  • Water jets: IP x5
  • Patented, sealed blocking sockets

 

For price and info please email sales@hotektech.com or call 253-927-6186

Related Instruments

Digital Multimeters
Analog Multimeters
Clamp-On Meters
Ohmmeters
Bridges Wheatstone, Kelvin
1 kHz / -3 dB low-pass filter can be activated.
Temperature measurement with Pt100(0) resistance thermometer
Broad range capacitance measurement
Frequency and keying ratio measurement at 2 to 5 V signals or up to 1 MHz
Data memory and bidirectional infrared interface
Direct current measurement from 10 nA to 10 A, 16 A for short periods
  • Resolution: ± 12,000 digits, 4˝-place
  • 3 connector jacks with patented automatic blocking sockets (ABS)
  • Voltage measurement with a basic accuracy of ± 0.05% (V DC)
  • Auto-range current measurement from 100 μA (resolution: 10 nA) to 10 A (16A) via a single connector jack and a single fuse
  • Large, light-blue illuminated display with extra large characters (15 mm) and an analog bar graph for dynamic processes
  • Separate battery and fuse compartments
  • Measuring categories: 1000V CAT III and 600V CAT IV
  • Made in Germany
  • Furnished with DKD calibration certificate
     
  • 23 Multimeter Functions
  • Voltage ACTRMS, voltage AC+DC TRMS, voltage DC, frequency (Hz, MHz), keying ratio, resistance, diode test, continuity test, capacitance, current ACTRMS, current AC+DC TRMS,
    temperature with Pt 100/1000 sensors and type K thermocouples
  • Additional filter function and voltage measurement with reduced input impedance for limiting interference, for example when performing measurements at frequency converters
  • 4 MB data memory as data logger for long-term measurements
  • Power pack connector socket for operation without batteries
  • Infrared interface for communication with the PC
  • Protective rubber cover safeguards against shocks and impacts

Three Connector Jacks with Automatic Blocking Sockets (ABS) *
All current ranges are implemented via a single connector jack which prevents any
possibility of operator error.
Beyond this, the automatic blocking sockets prevent incorrect connection of the
measurement cables, as well as selection of the wrong measured quantity.
Danger to the user, the instrument and the device under test resulting from operator
error is thus ruled out.

Overload Protection
The instrument is safeguarded for up to 1000 V in all measuring functions by overload protection. Voltages of greater than 1000 V and current of greater than 10 or 16 A are indicated acoustically.
Dangerous contact voltages are indicated when the 1 kHz low pass filter is activated.
The FUSE display appears at instrument in order to indicate that the fuse for the current
measuring input has blown.

RMS Value with Distorted Waveshape
The utilized measuring method allows for wave shape independent RMS measurement
(TRMS AC and AC+DC) for voltage and current up to 20 kHz.

Filter for V AC Measurement
A 1 kHz low-pass filter can be activated if required, for example when measuring motor
voltage at electronic frequency converters.
The input signal is checked by a voltage comparator for dangerous voltages as long as the
low-pass filter is activated.

Measuring 5 V Square-Wave Signals.
This function makes it possible to test circuits and transmission cables by
measuring the frequency and the keying ratio of pulses with amplitudes of 2 to 5 V and
frequencies of 100 Hz to 1 MHz.

Analog Scale for Quick Trend Display – Bar Graph or Pointer
The analog scale (with additional negative range for zero frequency quantities) allows for
faster recognition of measured value fluctuation than is possible with a digital display.
The instrument can be switched back and forth between bar graph and pointer display.

Automatic or Manual Measuring Range Selection
Measured quantities are selected by means of a rotary switch and a function key.
The measuring range is automatically matched to the measured values.
The measuring range can also be selected and fixed manually with a key.

 

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [GMC] [Top] [Distribution] [Contact Us]