AF033A

|
Flexible Current Sensor
5.. 300A:3V, 100mV/A, Loop
Length 600mm, 1%VAusg.+50mV
These sensors are
well suited for the measurement of alternating current at
difficult to access locations. They are highly insulated and can
generally be switched at a ratio of 1:10 with a range selector.
They can be operated within a frequency range of up to 20 kHz.
Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply
power is provided with a 9 V battery with a service life of
approx. 150 hours.
|
|
AF101A

|
Flexible Current Sensor
5.. 10kA:1V, 1mV/A, Loop
Length 1200mm, 1%VAusg.+2mV
These sensors are
well suited for the measurement of alternating current at
difficult to access locations. They are highly insulated and can
generally be switched at a ratio of 1:10 with a range selector.
They can be operated within a frequency range of up to 20 kHz.
Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply
power is provided with a 9 V battery with a service life of
approx. 150 hours.
|
|
AF11A

|
Flexible Current Sensor
5.. 1kA:1V, 1mV/A, Loop
Length 450mm, 1%VAusg.+2mV
These sensors are
well suited for the measurement of alternating current at
difficult to access locations. They are highly insulated and can
generally be switched at a ratio of 1:10 with a range selector.
They can be operated within a frequency range of up to 20 kHz.
Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply
power is provided with a 9 V battery with a service life of
approx. 150 hours.
|
|
AF33A
|
Flexible Current Sensor
5.. 3kA:3V, 10mV/A, Loop
Length 900mm, 1%VAusg.+5mV
These sensors are
well suited for the measurement of alternating current at
difficult to access locations. They are highly insulated and can
generally be switched at a ratio of 1:10 with a range selector.
They can be operated within a frequency range of up to 20 kHz.
Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply
power is provided with a 9 V battery with a service life of
approx. 150 hours.
|
|
|
|
BD23A

|
Interface Adapter
for METRAHit Multimeters
Can be snapped
onto all METRAHit multimeters. The infrared interface allows for
electrically isolated data transmission between PC and
multimeter.
Data transmission is indicated visually by means of two LEDs.
The BD 232
interface adapter is especially recommended for measuring
instruments with integrated memory
(METRAHit22M, 26M, 29S and 30M) .
But for online data transmission it can be used with all
multimeters METRAHit.
The BD-Pack
is available as a user-friendly complete package for
single-channel operation. In order to expand to 2, 3 or
4-channel operation, one BD232 is required for each channel, as
well as the additionally required multimeters.
|
|
EMA1
|
Energy Measuring Adapter for
Ferraris Meters
The EMA1 is a plug-in adapter for
the METRAHit 29S digital multimeter for the measurement of
energy at Ferraris meters without modifying the installation
set-up.
|
|
F829
|
Carrying pouch for 1
METRAHit with rubber cover and sensors or for 1 METRAmax
Dimensions: 205 x
105 x 95 mm
|
|
F836
|
Ever-ready case for 1 METRAHit with cable
compartment
Dimensions: 175 x
210 x 75 mm
|
|
F840
|
Ever-ready case for 2 METRAHit, 2 adapters +
accessory
Dimensions: 305 x
285 x 70 mm
|
|
FMA1
|
E+B Field Measuring Adapter for Multimeter
METRAHit 26..29S
Field measuring adapter for low
frequency interference signals for connection to METRAHit
E field 0...300V/m ... 30 000V/m, 10 %
B field 0 ... 3 µT ... 300 µT, 5 %
Frequency 15 Hz ... 100 kHz,
2 kHz low-pass filter can be activated,
with METRAHit 26 only up to 20 kHz
|
|
GH18
|
Protective rubber cover and carrying strap
|
|
HC20
|
Hard case for 1 METRAHit and accessory
Dimensions: 275 x
229 x 83 mm
|
|
HC30
|
Hard case for 2 METRAHit and accessory
Dimensions: 394 x
294 x 106 mm
|
|
HV3
|
High-Voltage
Probe, 3kV/3V
The HV3 probe is
suitable for measurements of up to 3 kV.
It simultaneously serves as a low pass filter for frequency
converter signals.
|
|
HV30
|
High-Voltage
Probe, 30kV/30V
The HV30
high-voltage probe (VDE approved) can be used for safe
measurement of direct voltages of up to 30 kV.
|
|
KC2

|
Kelvin Clip - diameters of up to 10 mm
Kelvin clips are
used for connecting low impedance resistors
(e.g. contact resistors, shunts etc.) to an ohmmeter with 4-wire
connection.
This allows for compensation of cable resistance.
|
|
KC3
|
Kelvin Clip - diameters of up to 4 mm
Kelvin clips are
used for connecting low impedance resistors
(e.g. contact resistors, shunts etc.) to an ohmmeter with 4-wire
connection.
This allows for compensation of cable resistance.
|
|
KS17-2

|
Cable Set
Each cable set
consists of two measurement cables with permanently attached
test probes at one end, and contact-protected angle plugs
(KS17-2) or banana plugs (KS21) at the other end. Hook clips,
alligator clips or cable lugs can be plugged on to the test
prods for special measuring tasks (see multimeter accessories on).
|
|
KS30

|
Probe for up to 1000 V for Power Installations
The high
impedance KS30 voltage probe offers additional protection
against overvoltages and operator error for measurements at high
energy voltage sources.
|
|
KY94
|
Hook Clips (1 Pair) for KS17-2
|
|
KY95-1
|
Alligator Clips (1 Pair) for KS17-2
|
|
KY96
|
Plug-On Lugs (1 Pair) for KS17-2
|
PMA16
|
Power Measuring Adapter
The PMA16 power measuring adapter
is an intermediate plug-in device for the measurement of power
consumption for single phase load components.
|
|
R200k
|
Ri Adapter, 200KOhm/230V
The
RI adapter is a load resistor which reduces the high input
resistance of concurrent measuring instruments from about 10 MW
to approximately 200 kW.
The RI adapter is plugged onto the measuring instrument with the
help of safety sockets and reduces the load resistance at the
measuring point to approximately 198 kW with its integrated 200
kW resistor.
|
|
SM16
|
Current Measuring Adapter
For safe and trouble-free
measurement of power consumption at load components connected
via mains plug. The attached cable with contact protected
terminals can be directly connected to the current measurement
jacks at the multimeter.
|
|
TF220
|
pt 1000 Immersion Probe for
Measurements in Gas and Liquid
Pt 1000 immersion sensor, water-tight and oil-proof, for
electrical household appliances, class A IEC 751, - 50 ... 220
° C
|
|
TF550
|
Pt 1000 Immersion Probe for Measurements from -50°...
+550°C
Pt 1000
temperature sensor for ovens and refrigerators,
class B IEC 751, -50 ... +550°C
|
|
TS-Chipset
|
10 Adhesive Temperature
Sensors, -50°-550°C
Miniature Pt 100
sensor for spot measurements at small measuring points,
class B IEC 751, - 50 ... + 550 ° C
|
|
WZ11A

|
Clamp-On Current
Transformer 200 A AC
15 ... 200A AC, ... 1mA/A AC/DC, 3%
|
|
WZ11B

|
Clamp-On Current Transformer
200A AC
Adjustable: 20 ... 200A AC, ... 1 mA/A AC/DC, 3%, output: 2V AC
|
|
WZ12A

|
Clamp-On Current Transformer with
Cable,
15 ... 180A AC, ... 1mA/A AC, 1000:1, +-3%
|
|
WZ12B

|
Clamp-On Current
Sensor,
10mA ... 100A
AC, 1mV/10mA, +-2%
|
|
WZ12C

|
Clamp-On Current
Sensor,
1mA ... 10A AC, 1mV/10mA
AC, 1A ... 120A AC, 1mV/A
|
|
WZ12D

|
Clamp-on current transformer,
15mA ... 150A AC, 1000:1, +-2,5%
|
|
WZ12E

|
Clamp-on current transformer,
0,2A ... 150A, 10mV/A, +-2% +-10mA
|
|
WZ12F

|
Clamp-on current transformer,
20mA ... 15A, 100mV/A, +-2% +-1mA
|
|
Z13B

|
Clamp-On Current Transformer
... 60/600AAC/DC; 40/400AAC, 50mm, 10mV/A; 1mV/A, 1,5%; 2%
|
|
Z201A

|
Clamp-On Current Transformer
.. 30AAC/DC; 20AAC, 19mm, 100mV/A, 1%
|
|
Z202A

|
Clamp-On Current Transformer
.. 30/300AAC/DC; 20/200AAC, 19mm, 10mV/A; 1mV/A, 1%+0,03A
|
|
Z203A

|
Clamp-On Current Transformer
.. 0,3/1kAAC/DC; 0,2/1kAAC, 31mm, 1mV/A, 1%+0,5A
|
|
Z3241
|
Interface cable RS232 for connecting PC - measuring
instrument
Length 2 meter
|
|
Z3409
|
Standard pt 100 Sensor for
Surface and Immersion Measurements
Standard Pt 100 temperature
sensor for surface and immersion measurements,
class A IEC 751,
- 40 ... + 600 ° C
|
|
Z3431-2

|
High Frequency
Probe, 100kHz - 750MHz, 0.25..50V AC
Alternating
currents with amplitudes ranging from 0.25V to 50V within a
frequency range of 100kHz to 750MHz can be measured with the
Z3431-2 high frequency probe. Alternating voltages are rectified
at a ratio of 1:1.
An input resistance of 10MW is required at the measuring
instrument.
|
|
Z3431-3
|
Temperature Probe,
with a permanently mounted sensor
NiCr-Ni, -20°C-+350°C
- Sensor type:
NiCr-NiAl, type K thermocouple
- Measuring
range: -20 ... +350 °C
- Accuracy: ±(0,5%
rdg.+ 0,5 °C)
- Required
multimeter input impedance: > 10 kOhm
- Output voltage:
1 mV / ° C
connect output with mV/V input of the multimeter
- Operating
temperature: 5 ... 45 ° C
- Dimensions:
118 x 37 x 211 mm
- Weight: 140g
- Power supply:
1,5 V baby cell, 250 hour service life
|
|
Z3431-4

|
Temperature Probe,
NiCr-Ni, -25°C-1150°C
- Sensor type:
NiCr-NiAl, type K thermocouple
- Measuring
range: -25 ... +1150 °C
- Accuracy: ±(1%
rdg.+ 1 °C)
- Required
multimeter input impedance: > 10 kOhm
- Output voltage:
1 mV / ° C
connect output with mV/V input of the multimeter
- Operating
temperature: 5 ... 45 ° C
- Dimensions:
118 x 37 x 211 mm
- Weight: 110g
- Power supply:
1,5 V baby cell, 250 hour service life
|
|
Z3431-5
|
Standard Plug-On Immersion
Probe, to +1100°C
|
|
Z3431-6

|
Plug-On Surface
Probe, to +850°C
|
|
Z3431-7
|
Plug-On Ribbon
Probe, to +450°C
|
|
Z3431-8
|
Flexible, Plug-On Insulation
Probe, to 250°C
|
|
Z3431-9
|
Temperature Probe,
without sensor
NiCr-Ni, -20°C-+350°C
- Sensor type:
NiCr-NiAl, type K thermocouple
- Measuring
range: -20 ... +350 °C
- Accuracy: ±(0,5%
rdg.+ 0,5 °C)
- Required
multimeter input impedance: > 10 kOhm
- Output voltage:
1 mV / ° C
connect output with mV/V input of the multimeter
- Operating
temperature: 5 ... 45 ° C
- Dimensions:
118 x 37 x 211 mm
- Weight: 110g
- Power supply:
1,5 V baby cell, 250 hour service life
|
|
|
|
|
Z3450

|
Leakage Current Measurement
Adapter, DIN VDE 0107/
0750
The Z3450 leakage
current measuring adapter is used in combination with RMS
multimeters for the measurement of contact voltage in accordance
with DIN VDE 0107, paragraph 10, and for the measurement of
continuous leakage and auxiliary patient current per DIN VDE
0750, part 1, IEC 601-1, EN 60 601-1.1990
|
Z3511
|
Clamp-On Current Transformer,
4 ... 500 A AC/
...1 mA/A AC/DC,
3%
|
|
Z3512

|
Clamp-On Current Transformer,
0.5 ... 1 000 A AC,
1 mA/A AC/DC,
0.5 ... 0.7%
|
|
Z3514
|
Clamp-On Current Transformer
1.. 2000AAC,
64x150mm,
1mA/AACDC,
0,5%
+0,1A
|