All ProductsAnalyticalAnalyzersCalibratorsHumidityData LoggersLight MetersMeasurement

 

MultimetersOhmmetersPressureStandardsTemperatureTransmitters

   ACCESSORIES FOR MULTIMETERS

AF033A

 

Flexible Current Sensor 

5.. 300A:3V, 100mV/A, Loop Length 600mm, 1%VAusg.+50mV

These sensors are well suited for the measurement of alternating current at difficult to access locations. They are highly insulated and can generally be switched at a ratio of 1:10 with a range selector. They can be operated within a frequency range of up to 20 kHz. Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply power is provided with a 9 V battery with a service life of approx. 150 hours.

 

AF101A
 

 

Flexible Current Sensor 

5.. 10kA:1V, 1mV/A, Loop Length 1200mm, 1%VAusg.+2mV

These sensors are well suited for the measurement of alternating current at difficult to access locations. They are highly insulated and can generally be switched at a ratio of 1:10 with a range selector. They can be operated within a frequency range of up to 20 kHz. Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply power is provided with a 9 V battery with a service life of approx. 150 hours.

AF11A
 

 

Flexible Current Sensor 

5.. 1kA:1V, 1mV/A, Loop Length 450mm, 1%VAusg.+2mV

These sensors are well suited for the measurement of alternating current at difficult to access locations. They are highly insulated and can generally be switched at a ratio of 1:10 with a range selector. They can be operated within a frequency range of up to 20 kHz. Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply power is provided with a 9 V battery with a service life of approx. 150 hours.

AF33A
 

 

Flexible Current Sensor 

5.. 3kA:3V, 10mV/A, Loop Length 900mm, 1%VAusg.+5mV

These sensors are well suited for the measurement of alternating current at difficult to access locations. They are highly insulated and can generally be switched at a ratio of 1:10 with a range selector. They can be operated within a frequency range of up to 20 kHz. Max. phase error is 2.5° at a frequency of up to 1 kHz. Supply power is provided with a 9 V battery with a service life of approx. 150 hours.

 

For price and info please email sales@hotektech.com or call 253-927-6186

Please check related
Instruments
Digital Multimeters
Analog Multimeters
Clamp-On Meters
Ohmmeters
Bridges Wheatstone, Kelvin
 

BD23A

 

Interface Adapter for METRAHit Multimeters

Can be snapped onto all METRAHit multimeters. The infrared interface allows for electrically isolated data transmission between PC and multimeter. 
Data transmission is indicated visually by means of two LEDs.

The BD 232 interface adapter is especially recommended for measuring instruments with integrated memory (METRAHit22M, 26M, 29S and 30M) . 
But for online data transmission it can be used with all multimeters METRAHit.

The BD-Pack is available as a user-friendly complete package for single-channel operation. In order to expand to 2, 3 or 4-channel operation, one BD232 is required for each channel, as well as the additionally required multimeters.

EMA1

Energy Measuring Adapter for Ferraris Meters

The EMA1 is a plug-in adapter for the METRAHit 29S digital multimeter for the measurement of energy at Ferraris meters without modifying the installation set-up.

F829 

Carrying pouch for 1 METRAHit with rubber cover and sensors or for 1 METRAmax

Dimensions: 205 x 105 x 95 mm

F836 

Ever-ready case for 1 METRAHit with cable compartment

Dimensions: 175 x 210 x 75 mm

F840 

Ever-ready case for 2 METRAHit, 2 adapters + accessory

Dimensions: 305 x 285 x 70 mm

FMA1

E+B Field Measuring Adapter for Multimeter METRAHit 26..29S

Field measuring adapter for low frequency interference signals for connection to METRAHit
E field 0...300V/m ... 30 000V/m, 10 %
B field 0 ... 3 µT ... 300 µT, 5 %
Frequency 15 Hz ... 100 kHz, 
2 kHz low-pass filter can be activated, 
with METRAHit 26 only up to 20 kHz

GH18

 

Protective rubber cover and carrying strap

HC20 

Hard case for 1 METRAHit and accessory

Dimensions: 275 x 229 x 83 mm

HC30

Hard case for 2 METRAHit and accessory

Dimensions: 394 x 294 x 106 mm

HV3

High-Voltage Probe, 3kV/3V

The HV3 probe is suitable for measurements of up to 3 kV. 
It simultaneously serves as a low pass filter for frequency converter signals.

HV30

High-Voltage Probe, 30kV/30V

The HV30 high-voltage probe (VDE approved) can be used for safe measurement of direct voltages of up to 30 kV.

KC2

Kelvin Clip - diameters of up to 10 mm

Kelvin clips are used for connecting low impedance resistors 
(e.g. contact resistors, shunts etc.) to an ohmmeter with 4-wire connection. 
This allows for compensation of cable resistance.

 

KC3
 

Kelvin Clip - diameters of up to 4 mm

Kelvin clips are used for connecting low impedance resistors 
(e.g. contact resistors, shunts etc.) to an ohmmeter with 4-wire connection. 
This allows for compensation of cable resistance.

KS17-2

Cable Set

Each cable set consists of two measurement cables with permanently attached test probes at one end, and contact-protected angle plugs (KS17-2) or banana plugs (KS21) at the other end. Hook clips, alligator clips or cable lugs can be plugged on to the test prods for special measuring tasks (see multimeter accessories on).

 

KS30

Probe for up to 1000 V for Power Installations

The high impedance KS30 voltage probe offers additional protection against overvoltages and operator error for measurements at high energy voltage sources.

 

KY94

Hook Clips (1 Pair) for KS17-2

KY95-1

Alligator Clips (1 Pair) for KS17-2

KY96

Plug-On Lugs (1 Pair) for KS17-2

PMA16

Power Measuring Adapter

The PMA16 power measuring adapter is an intermediate plug-in device for the measurement of power consumption for single phase load components.

R200k
 

Ri Adapter, 200KOhm/230V

The RI adapter is a load resistor which reduces the high input resistance of concurrent measuring instruments from about 10 MW to approximately 200 kW.
The RI adapter is plugged onto the measuring instrument with the help of safety sockets and reduces the load resistance at the measuring point to approximately 198 kW with its integrated 200 kW resistor.

SM16

Current Measuring Adapter

For safe and trouble-free measurement of power consumption at load components connected via mains plug. The attached cable with contact protected terminals can be directly connected to the current measurement jacks at the multimeter.

TF220

pt 1000 Immersion Probe for Measurements in Gas and Liquid

Pt 1000 immersion sensor, water-tight and oil-proof, for electrical household appliances, class A IEC 751, - 50 ... 220 ° C

TF550

Pt 1000 Immersion Probe for Measurements from -50°... +550°C

Pt 1000 temperature sensor for ovens and refrigerators, 
class B IEC 751, -50 ... +550°C

TS-Chipset
10 Adhesive Temperature Sensors, -50°-550°C

Miniature Pt 100 sensor for spot measurements at small measuring points, 
class B IEC 751, - 50 ... + 550 ° C

WZ11A

Clamp-On Current Transformer 200 A AC 

15 ... 200A AC, ... 1mA/A AC/DC, 3%

WZ11B
 

Clamp-On Current Transformer 200A AC 

Adjustable: 20 ... 200A AC, ... 1 mA/A AC/DC, 3%, output: 2V AC

WZ12A
 

Clamp-On Current Transformer with Cable, 

15 ... 180A AC, ... 1mA/A AC, 1000:1, +-3%

WZ12B
 

Clamp-On Current Sensor

10mA ... 100A AC, 1mV/10mA, +-2%

WZ12C
 

Clamp-On Current Sensor

1mA ... 10A AC, 1mV/10mA AC, 1A ... 120A AC, 1mV/A

WZ12D
 

Clamp-on current transformer

15mA ... 150A AC, 1000:1, +-2,5%

WZ12E
 

Clamp-on current transformer

0,2A ... 150A, 10mV/A, +-2% +-10mA

WZ12F
 

Clamp-on current transformer

20mA ... 15A, 100mV/A, +-2% +-1mA

Z13B
 

Clamp-On Current Transformer

 ... 60/600AAC/DC; 40/400AAC, 50mm, 10mV/A; 1mV/A, 1,5%; 2%

 

Z201A

Clamp-On Current Transformer 

.. 30AAC/DC; 20AAC, 19mm, 100mV/A, 1%

Z202A

Clamp-On Current Transformer

 .. 30/300AAC/DC; 20/200AAC, 19mm, 10mV/A; 1mV/A, 1%+0,03A

Z203A

Clamp-On Current Transformer 

.. 0,3/1kAAC/DC; 0,2/1kAAC, 31mm, 1mV/A, 1%+0,5A

Z3241

Interface cable RS232 for connecting PC - measuring instrument

Length 2 meter

 

Z3409 

Standard pt 100 Sensor for Surface and Immersion Measurements

Standard Pt 100 temperature sensor for surface and immersion measurements, 
class A IEC 751, 
- 40 ... + 600 ° C

Z3431-2 

High Frequency Probe, 100kHz - 750MHz, 0.25..50V AC

Alternating currents with amplitudes ranging from 0.25V to 50V within a frequency range of 100kHz to 750MHz can be measured with the Z3431-2 high frequency probe. Alternating voltages are rectified at a ratio of 1:1. 
An input resistance of 10MW is required at the measuring instrument.

Z3431-3
 

Temperature Probe, with a permanently mounted sensor
NiCr-Ni, -20°C-+350°C
  • Sensor type: NiCr-NiAl, type K thermocouple
  • Measuring range: -20 ... +350 °C
  • Accuracy: ±(0,5% rdg.+ 0,5 °C)
  • Required multimeter input impedance: > 10 kOhm
  • Output voltage: 1 mV / ° C
    connect output with mV/V input of the multimeter
  • Operating temperature: 5 ... 45 ° C
  • Dimensions: 118 x 37 x 211 mm 
  • Weight: 140g  
  • Power supply: 1,5 V baby cell, 250 hour service life

Z3431-4

 

Temperature Probe
NiCr-Ni, -25°C-1150°C
  • Sensor type: NiCr-NiAl, type K thermocouple
  • Measuring range: -25 ... +1150 °C
  • Accuracy: ±(1% rdg.+ 1 °C)
  • Required multimeter input impedance: > 10 kOhm
  • Output voltage: 1 mV / ° C
    connect output with mV/V input of the multimeter
  • Operating temperature: 5 ... 45 ° C
  • Dimensions: 118 x 37 x 211 mm 
  • Weight: 110g 
  • Power supply: 1,5 V baby cell, 250 hour service life

 

Z3431-5
 

Standard Plug-On Immersion Probe, to +1100°C

Z3431-6 

Plug-On Surface Probe, to +850°C

Z3431-7
 

Plug-On Ribbon Probe, to +450°C

Z3431-8
 

Flexible, Plug-On Insulation Probe, to 250°C

Z3431-9
 

Temperature Probe, without sensor
NiCr-Ni, -20°C-+350°C
  • Sensor type: NiCr-NiAl, type K thermocouple
  • Measuring range: -20 ... +350 °C
  • Accuracy: ±(0,5% rdg.+ 0,5 °C)
  • Required multimeter input impedance: > 10 kOhm
  • Output voltage: 1 mV / ° C
    connect output with mV/V input of the multimeter
  • Operating temperature: 5 ... 45 ° C
  • Dimensions: 118 x 37 x 211 mm 
  • Weight: 110g  
  • Power supply: 1,5 V baby cell, 250 hour service life
   

Z3450
 

Leakage Current Measurement Adapter, DIN VDE 0107/ 0750

The Z3450 leakage current measuring adapter is used in combination with RMS multimeters for the measurement of contact voltage in accordance with DIN VDE 0107, paragraph 10, and for the measurement of continuous leakage and auxiliary patient current per DIN VDE 0750, part 1, IEC 601-1, EN 60 601-1.1990

Z3511

Clamp-On Current Transformer

4 ... 500 A AC/
 ...1 mA/A AC/DC, 
3%

Z3512

 

Clamp-On Current Transformer,

 0.5 ... 1 000 A AC, 
1 mA/A AC/DC, 
0.5 ... 0.7%

 

Z3514

Clamp-On Current Transformer

 1.. 2000AAC
64x150mm, 
1mA/AACDC
0,5%
+0,1A

 

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [GMC] [Top] [Distribution] [Contact Us]