PROFITEST 0100S-II 

PROFITEST 0100S-II Test Instrument for VDE 0100 / IEC 364-6-61

PROFITEST 0100S-II Test Instrument for VDE 0100 / IEC 364-6-61
DIN VDE 0100, part 610 Tester
The PROFiTEST 0100S-II allows for testing of all protective measures as required by 
DIN VDE 0100, part 610, as well as corresponding international standards 
(e.g. IEC 64-8, HD 364-6-61.S1).



DIN VDE 0100, part 610 Tester

Testing of Residual-Current Protective Devices (RCCBs)

  • Measurement of contact voltage without
    tripping the RCCB Contact voltage with
    reference to nominal residual current is
    measured with 1/3 of nominal residual current.

  • Trip test with nominal residual current, measurement of time to trip

Special Testing for Systems and RCCBs

  • Testing of systems and RCCBs
    with rising residual current and display of tripping current, as well as contact voltage at the moment tripping occurs.

  • Testing of RCCBs (10 and 30 mA) with 5 • IDN

  • Testing of RCCBs which are suitable for pulsating DC fault current, testing is conducted with positive or negative half-waves.

  • Testing of RCCBs with adjustable residual current
    for the determination of contact voltage and tripping current

Testing of Special RCCBs

  • Selective , SRCDs, PRCDs (Schukomat, Sidos etc.), type G

    Testing of RCD Protection in IT Systems

Large Voltage and Frequency Range
An extended-range measuring system allows for use of the test instrument for all AC and three-phase systems with voltages ranging from 65 to 500 V, and frequencies from 15.4 to 420 Hz.

Loop and System Impedance Measurement
Measurement of loop and system impedance can be performed within a range of 65 to 550 V. Conversion to short-circuit current is based upon respective line voltage, as long as the measured line voltage is within the prescribed range. Short-circuit current is calculated from actual line voltage and measured impedance for line voltages outside of this range.
With a test current of 15 mA the loop impedance can also be determined after RCCBs with a nominal residual current of at least 30 mA without the RCCB being tripped.

Insulation Resistance Measurement with Nominal Voltage and Variable or Rising Test Voltage
Insulation resistance is usually measured with the nominal voltages 500 V, 250 V or 100 V. For measurements at sensitive components, as well as within systems with voltage limiting devices, 22 different test voltages ranging from 20 to 500 V can be selected, which deviate from, and are generally lower than nominal voltage. Measurements can be performed with continuously rising voltage for the detection of weak points in insulation, as well as for the determination of response voltages for voltage limiting devices. Voltage at the device under test, any detected response or breakdown
voltage, as well as insulation resistance appear at the instrument’s display, and an LED indicates violation of an (adjustable) limit value.

Low-Resistance Measurements
Bonding conductor resistance and protective conductor resistance can be measured with a measuring current of >= 200 mA DC, automatic measuring voltage polarity reversal and selectable conduction direction. Violation of an (adjustable) limit value is signaled with an LED.

Standing-Surface Insulation Measurement
Measurement of standing-surface insulation is performed with actual line frequency and line voltage.

Universal Connector System
The interchangeable plug inserts and the plug-on 2-pole adapter (can be expanded to a 3-pole adapter for phase sequence measurements) allow for use of the test instrument all over the world.

Special Features

  • Display of allowable fuse types for electrical systems

  • Start-up testing for energy consumption meters

  • Calculation of cable lengths for common copper conductor cross-sections

  • Measurement of biasing, leakage and circulating current up to 1 A, as well as working current to 150 A with the Clip 0100S accessory clip-on current sensor

  • Phase sequence measurement (phase sequence, highest line-to-line voltage)

  • Temperature and humidity measurement with adapter Z541A as accessory equipment