  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

POWER CURRENT ENERGY VOLTAGE FREQUENCY PHASE ANGLE TRANSDUCERS


SINEAX M 563 Power & Current Transducer Transmitter


Power & Current Transducer Transmitter  

Power & Current Transducer Transmitter  

Sine, Rectangular or Distorted Wave Forms
3 Analog Outputs
Measures any Three: P, Q or S, I ~, U ~ (RMS), 
cos, sin j, LF, PF, QF, f
Data Logging Function
RS 232 PC Programming Interface
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 57-400 V 
phase-to-neutral 100-693 V phase-to-phase 50/60 Hz
Output:0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V

SINEAX DME 424 & DME 442 Energy Transducers Transmitters


Energy Transducer Transmitter

Energy Transducer Transmitter

DME 424 with 2 analog and 4 digital pulse outputs
DME 442 with 4 analog and 2 digital pulse outputs
Sine, Rectangular or Distorted Wave Forms
Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, 
PF, QF, f
Data Logging Function
RS 232 PC Programming Interface
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 
57-400 V phase-to-neutral 100-693 V phase-to-phase 50/60 Hz
Output:0-20 mA, 4-20 mA 0-1 V to 0-10 V, 2-10 V
Open Collector Pulse

SINEAX DME 406 Energy Transducer Transmitter


Energy Transducer Transmitter

Energy Transducer Transmitter

Sine, Rectangular or Distorted Wave Forms
Measures P, Q or S, I ~, U ~ (RMS), cos j, sin j, LF, 
PF, QF, f
Data Logging Function
RS 232 PC Programming Interface
RS485 with Profibus DP output
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: Profibus DP

SINEAX P 530 Active Power & Q 531 Reactive Power Transducer


Reactive Power Transducer Transmitter

Reactive Power Transducer Transmitter

3-Phase with Balanced or Unbalanced Load
Sinusoidal Input
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
100-690 V
50/60 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

SINEAX I 538 AC Current Transducer Transmitter


AC Current Transducer Transmitter

AC Current Transducer Transmitter

Sinusoidal Input
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 Hz
Output:0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V

SINEAX I 542 AC Current Transmitter


AC Current Transducer Transmitter

AC Current Transducer Transmitter
 

Sinusoidal Input
Powered from Measuring Source
Transducer for AC Current, Self-Powered

Measurement method: Rectifier process
Measurement input: Alternating current, sinusoidal, arithmetic mean value measurement, effective value calibration
Measuring range: 1/5 A or 1.2/6 A selectable at terminals
Measurement output: Unipolar 0...1, 0...5, 0...10 or 
0...20 mA or 0...1 to 0...10 V
Power supply: without power supply terminal (self-powered), 
less wiring expense
Standard as marine version per Lloyd’s Register of Shipping

SINEAX I 552 True RMS AC Current Transducer


AC Current TRMS Transducer Transmitter

AC Current TRMS Transducer Transmitter

Sine, Rectangular or Distorted Wave Forms
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
50/60 or 400 Hz
Output:0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V

SINEAX U 539  AC Voltage Transducer Transmitter


AC Voltage Transducer Transmitter

AC Voltage Transducer Transmitter

Sinusoidal Input
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-50 V to 0-600 V
50/60 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

SINEAX U 543 AC Voltage Transducer Transmitter


AC Voltage Transducer Transmitter

AC Voltage Transducer Transmitter

Sinusoidal Input
Powered from Measuring Source

Input:0-20 V to 0-600 V
50/60 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

SINEAX U 553 True RMS AC Voltage Transducer Transmitter


AC Voltage Transducer Transmitter

AC Voltage Transducer Transmitter

Sine, Rectangular or Distorted Wave Forms
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-20 V to 0-690 V
50/60 or 400 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

SINEAX U 554 True RMS AC Voltage Transducer Transmitter


AC Voltage Transducer Transmitter

AC Voltage Transducer Transmitter

Sine, Rectangular or Distorted Wave Forms
Special Version to Allow Zero Offset
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-20 V to 0-690 V
50/60 or 400 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

SINEAX F 534  Frequency Transducer Transmitter


Frequency Transducer Transmitter

Frequency Transducer Transmitter

Sine, Rectangular or Distorted Wave Forms
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:10 V to 690 V
10 to 1.5 kHz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

SINEAX F 535 Frequency Difference Transducer Transmitter




Frequency Transducer Transmitter
Measure Δf Between 2 Synchronized Supplies
Sine, Rectangular or Distorted Wave Forms
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:10 V to 690 V
10 to 1.5 kHz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

SINEAX G 536 Phase Angle Transducer Transmitter


Phase Angle Transducer Transmitter

Phase Angle Transducer Transmitter
Measure Single or 3-Phase Balanced
Sine, Rectangular or Distorted Wave Forms
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:1 or 5 A
10 V to 690 V
16 to 400 Hz
0.5 cap. 1.ind. 0.5 cos Φ
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

SINEAX G 537 Phase Angle Difference Transducer Transmitter


Phase Angle Transducer Transmitter

Phase Angle Transducer Transmitter
Measure ΔΦ Between 2 Synchronized Supplies
Sine, Rectangular or Distorted Wave Forms
Available as Measuring Source Powered to 230 V
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:10 V to 690 V
50 or 60 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
±1 mA to ±20 mA
0-1 V to 2-10 V, to ±10 V

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or