PC10 Single and three phase power analyzer

PC10 Spectral Power Analyzer Converter measures, computes and transmits all your important power
variables to your computer.
The software lets you select the quantities you want to display on the PC/Notebook monitor.
The settings, such as auto or manual ranging are easily changed and measurements are stored at a
mouse click.
The PC Power Analyzer is available in single or three phase versions and combines
an ammeter, voltmeter, wattmeter and a spectrum analyzer in a single light weight package.

 PC Pover Analyzer-Converter
We accept credit cards and purchase orders
253-927-6186
253-927-6189

PC10 Power analyzer

Model  Description  List Price  Sale Price 
PC10-1/0.1  Single Phase Spectral Power Converter, 0.1% accuracy Call  Call 
PC10-1/0.05  Single Phase Spectral Power Converter, 0.05% accuracy Call  Call 
PC10-3/0.1  Three Phase Spectral Power Converter, 0.1% accuracy Call  Call 
PC10-3/0.05  Three Phase Spectral Power Converter, 0.05% accuracy Call  Call 

From the simultaneous and precise voltage and current measurement you can obtain the RMS,
rectified mean, mean, min, max and harmonics through the 99th order.
Particular care has been taken to obtain precise power readings (watts, VA, VAR and power factor) at
highly distorted signals. Other values determined are: frequency, crest- and form factor, THD, Wh, VAh,
VARh, Ah, harmonics of power, harmonics of impedance (magnitude and phase) and line-to-line voltages.

The PC10's combination of high frequency performance, excellent common mode rejection and simultaneous
measurements is needed for accurate readings on inverter drives, switched mode power supplies and
ballast lighting equipment.
The current input from 15mA to 40A can be extended to 100A with our option, or you can use your own Hall
sensor for current measurements up to 20kA. A shunt input for high frequency current viewing resistors or
current clamps is included. Measurement accuracy of 0.1% in a compact, light weight instrument is useful
in the laboratory, in the field and in automatic test systems.

Power Analyzer specification

PC10 Power Analyzer Converter
Voltage Ranges, 8 ranges 1-3-10-sequence; 0.3V, 1V, 3V, 10V, 30V, 100V, 300V, 1000V
Frequency range  DC, 0.1Hz-1MHz 
Crest Factor  3:1 at 50% full scale (fs) 
Input Impedance  less than 1MΩ 
Common Mode - 50Hz/100kHz  160dB/100dB 
Standard accuracy 23°C; rms, mean, rectified mean; 0.3V typical
1Hz-1kHz = ±(0.1% rdg + 0.1% range)
DC, 1kHz-10kHz = ±(0.2% rdg + 0.2% range)
10kHz-100kHz = ±(0.3% range + 0.04%/kHz rdg)
100kHz-300kHz = ±(0.3% range + 0.04%/kHz rdg), typical 
Improved accuracy
 ±(0.05% rdg + 0.07% range ) 
Current 13 Ranges: 1.5mA, 5mA, 15mA, 50mA, 150mA, 500mA, 1.5A, 5A; 1A, 3A, 10A, 30A, 100A Max. 1A, 5A, 30A, resp.
Frequency range  DC, 0.1Hz-300kHz 
Crest Factor  3:1 at 50% full scale (fs) 
Common Mode - 50Hz/100kHz  160dB/120dB 
Standard accuracy 23°C; 1A-, 5A-, shunt input
1Hz-1kHz DC,      ±(0.1% rdg + 0.1% range)
1kHz-10kHz          ±(0.2% rdg + 0.2% range)
10kHz-100kHz      ±(0.3% rdg + 0.04%/kHz rdg)
100kHz-300kHz    ±(0.3% rdg + 0.04%/kHz rdg)
Lowest ranges 1.5mA, 15mA
1A typical.
Improved accuracy 1Hz-400Hz
±(0.05% rdg + 0.07% range) 
Power 104 ranges corresponding to the products V x A
Frequency range  DC, 0.1Hz-300kHz 
Accuracy 23°C ±3°C
45Hz-65Hz ±(0.1% rdg + 0.01% range)
1Hz-1kHz Add accuracy percentage of current and voltage
DC, 1kHz-10kHz +0.04%/kHz PF
10kHz-100kHz 

PF = 0 to ±0.1
PF = 0 to ±1
PF = 0 to ±1
PF = 1 
Frequency  0.1Hz-400kHz, V triggered; Accuracy ±0.1%  
Computed 
Values
Accuracy; Reactive Power, Var = ±(VA² - W²)½;
Apparent Power: VA = Arms Vrms; Power Factor: PF = W/VA; 
Crest Factor: CF = Ap/Arms, Vp/Vrms; Form Factor: FF = At/Arms, Vt/Vrms; Impedance: Z = Vrms/Arms;
Total Harm Dist: THD = (Irms² - IFund²)½/Irms
Add accuracy percentage
figures of values involved
in computation. 
Integrator Energy, Charge; Accuracy - Wh, VAh, Varh, Ah; Basic accuracy of integrated quantity.
Harmonic
Analysis
Frequency range of fundamental - 2.5Hz-100kHz
Range of harmonic  1-99 
Accuracy, Harmonic current and voltage
2Hz-1kHz = ±(0.1% rdg + 0.1% range)
1kHz-10kHz = ±(0.5% rdg + 0.5% range)
10kHz-100kHz = ±(0.7% range + 0.1%/kHz rdg),typical 
 
Options IEEE-488-2, RS232, Centronics printer output
4 programmable analog outputs, single-, sum-, or average values
4 Analog inputs 0-±5V, input impedance 200kΩ
4 Analog inputs 0-±10V, input impedance 200kΩ
Rack mounting kit
Windows Operating Software (95 - Vista), transformer-motor testing
0 - ±5V, accuracy 0.2%
0 - ±5V, accuracy 0.2%
0 - ±10V, accuracy 0.2%


Toll Free: 866-436-2430    Email: sales@hotektech.com