Toll Free: 866-436-2430                     Email: sales@hotektech.com
 
 
Instruments, calibrators, standards, analyzers, dataloggers. analyzers
 
  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

SEMI STANDARD PLATINUM RESISTANCE THERMOMETER


935-14-61 Semi Standard Platinum Resistance Thermometer Range -50 to +250°C
935-14-13 Semi Standard Platinum Resistance Thermometer Range -196 to +250°C
935-14-16 Semi Standard Platinum Resistance Thermometer Range -100 to +450°C
935-14-72 Semi Standard Platinum Resistance Thermometer Range -50 to +670°C
935-14-82 Semi Standard Platinum Resistance Thermometer Range -50 to +250°C
935-14-85 Semi Standard Platinum Resistance Thermometer Range -50 to +250°C
935-14-95 Semi Standard Platinum Resistance Thermometer Range -100 to +670°C

 
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Semi-standard PRTs are typically made in stainless steel sheaths which are 6mm in diameter, and have an Ro value of 100 ohms and an alpha [(R100-Ro)/Ro] of 0.00385. A variety of configurations are available, since particular characteristics might be required, such as short sensing length, fast response, or applicability to a particular temperature range. Most of our semi-standard PRTs have been made longer, and have a slightly wider temperature range. They are all constructed with high quality 100 ohm detectors, and are assembled and calibrated using fixed point cells in-house in a NAMAS approved and supervised laboratory. These sensors are ideal for a comparison reference sensor in industrial and secondary laboratories.

Ro 100Ω ±0.05Ω
Alpha 0.003850 ±0.000005
Stability 0.010 ohm/year
Calibration A NIST Calibration Certificate can be provided at extra cost
Recommended
Current
1mA
Self-Heating Error
at 1mA
0.004°C
Model Number 935-14-61 935-14-13 935-14-16 935-14-72 935-14-82 935-14-85 935-14-95
Diameter (A) 4mm 6mm 6mm 6mm 4mm 6mm 6mm
Length (B) 300mm 350mm 450mm 375mm 210mm 420mm 450mm
Sensing Length 6mm 25mm 25mm 25mm 6mm 25mm 25mm
Handle (C) Yes Yes Yes No No (Angled) No (Angled) Yes
Cable (D) 2m PTFE
4 wire
2m PTFE
4 wire
2m PTFE
4 wire
2m PTFE
4 wire
1.5m PTFE 4 wire 540mm PTFE
4 wire
2mPTFE
4 wire
Temperature Range -50 to
+250°C
-196 to
+250°C
-100 to
+450°C
-50 to +670°C -50 to
+250°C
-50 to
+250°C
-100 to
+670°C
Application Fast Response Low-Temp. Use General
Use
Gemini
Jupiter
Europa
Venus
Calisto
Oceanus-6 General Use
Medusa
Features Small Stem
Conduction
Copper Earth Screen 316 stainless steel sheath Fits lid of
Carry-case
General Purpose General Purpose Metal Alloy
Sheath

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or