  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

DRY BLOCK CALIBRATOR


Gemini 550 Dry Block Calibrator. Temperature range 35ºC to 550ºC
Gemini 700 Dry block Temperature Calibrator. Temperature range 50ºC to 700ºC
High Capacity Dry Block Calibrators.
The Gemini Dry block range differs from our other dry blocks with an enormous well capacity of more than 2.5” While still offering all the advantages you’ll find in other calibrators the Gemini has been designed to have a large block suitable for more probes.

The Gemini Dry block calibrators are available in two models, the BASIC (B) and the SITE (S).
The B model includes a sophisticated temperature controller with a dual display for Set Temperature and Dry Block Temperature. The large block has the benefit of higher capacity but with longer heating and cooling times compared to the fast response models.

Dry Block Calibrator
Dry Block Calibrator
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
  • Calibrate Whole Calibration Loop. Using a heat source rather than an electrical simulator a test
    instrument and probe can be calibrated as a system.

  • High Capacity Block -- Large Calibration volume for many sensors and low loading errors.

  • Two Operating Ranges -- Fast response from 35ºC to 550ºC (1022°F) or 50ºC to 700ºC (1292°F)

  • Simple To Use -- Outstanding Value for Money!

Includes as standard: 
Windows Software, Computer Interface and a Ramp to Set Point Feature.
Increased resolution of ±0.01 available throughout the range via the PC interface and 
from 0.01to +99.99 locally on the auto-ranging front display. 
The controller features multi-point block to display correction giving excellent absolute accuracy.
The SITE model has universal sensor input allowing Platinum Resistance Thermometers, Thermocouples (Types K, N, R, S, L, B, PL2, T, J and E) along with Linear Process Inputs including 4-20mA current transmitters to be displayed on the built-in indicator. 
The indicator can be programmed with up to five calibration points to provide high accuracy digital probe matching.
The indicator and controller are both addressable over the communications link.

Model Gemini 550 & Gemini 700
Temperature Range

Gemini 550: 35°C to 550°C
Gemini 700: 50°C to 700°C

Accuracy ≤±0.3°C Throughout entire range

Absolute Stability
Over 30 Minutes

±0.05°C
Computer Interface Included with Windows Software (page 106)
Cooling Time

Gemini 550: 550°C to 275°C in 35 min.
Gemini 700
: 550°C to 60°C in 345 min.

Heating Time

Gemini 550: 30°C to 550°C in 35 min.
Gemini 700: 50°C to 700°C in 110 min.

Best Performance See Graph
Calibration Volume Four 8mm pockets, four 19.5mm pockets,
Standard Block All 160mm deep
Display Resolution

0.01 to 99.99
0.1 100.0 to 700.0
PC can display 0.01 across whole range with the software included

Indicator Units °C, °F, K
Power

110 VAC ±10% (50 / 60 Hz)
600 Watts

Overall Dimensions 302mm x 176mm x 262mm (HxWxD)
Weight

Gemini 550: 18.7 lbs (8.5kg)
Gemini 700: 30.9 lbs (14kg)