All ProductsAnalyticalAnalyzersCalibratorsHumidityData LoggersLight MetersMeasurement

 

MultimetersOhmmetersPressureStandardsTemperatureTransmitters

HIGH TEMPERATURE DRY BLOCK CALIBRATOR
Pegasus 1200 High Temperature Dry Block Calibrator, 150 to 1200°C (2192°F)

Pegasus 1200 Dry Block Temperature Calibrator.
High Temperature Dry Block Calibrator, 150 to 1200°C (2192°F)
The Pegasus 1200 Dry Block Calibrator is a tube furnace, which includes a specially-profiled heater that gives a central zone of constant temperature. It is ideal for the calibration of noble metal thermocouples, type R and S, in industries such as glass making, electrical power, automotive and material processing. 
A state of the art digital controller with custom tuning and 5 discrete calibration points provides optimal control and accuracy throughout the full range of the unit.

PEGASUS 1200 - Very High Temperature Dry Block Calibrator
High Temperature Dry Block Calibrator
  • Calibrate Whole Calibration Loop - using a heat
    source rather than an electrical simulator,
    a test instrument and probe can be calibrated
    as a system

  • Custom furnace design - provides fast heating
    with optimized thermal profile

  • High Operating Range - Portable field use
    up to 1200°C

  • SITE Model Includes Universal Input Temperature
    Indicator allowing for up to five "correction" points
    to be programmed

  • Windows Software and PC Interface as Standard

  • Free Evaluation Report

Available in Site or Basic models, the Basic models utilize a high accuracy, high stability temperature controller which sets and gives an indication of the block temperature. 
A standard temperature sensor and external thermometer should be used to measure the block’s temperature, and industrial sensor outputs are compared to known and traceable values. 
The site models include an independent temperature indicator that may connect to an optional 
type R or type S thermocouple or PT100 standard probe, allowing the reference system to be housed in one convenient case.
The Pegasus 1200’s temperature range is 150ºC to 1200ºC. Its stabilization time is 15 minutes. 
The insert dimensions are: 4 holes 5/16” Ø x 3.2” deep (8mm x 80mm) and the insert options allow drillings to be made per customer specifications.

A fast cool down probe is available as an option. When connected to an air supply, this probe cools down the Pegasus 1200 in about 25% of the normal time. 
All Pegasus 1200 Models are supplied with RS232 or RS422 communications, and software.
The SITE model has universal sensor input allowing Platinum Resistance Thermometers, Thermocouples (Types K, N, R, S, L, B, PL2, T, J and E) along with Linear Process Inputs including 4-20mA current transmitters to be displayed on the built-in indicator. 
The indicator can be programmed with up to five calibration points to provide high accuracy digital probe matching.
The indicator and controller are both addressable over the communications link.

Model Pegasus 1200
Temperature Range 150°C to 1200°C

Absolute Stability
Over 30 Minutes

At 150°C
At 1200°C
Blackbody Source

±0.1°C
±0.2°C
±0.3°C

Computer Interface Included with Windows Software
Cooling Time

1200°C to 800°C in 50 minutes*
1200°C to 200°C in 180 minutes*
*substantially reduced by the cooling adapter

Heating Time 100°C to 1200°C in 20 minutes
Calibration Volume 33.5mm diameter by 130mm deep
Standard Insert 4 pockets, 8.0mm diameter by 80mm deep
Display Resolution

0.1 to 999.9
1     1000 to 1200
PC can display 0.1 across whole range with the software included

Indicator Units °C, °F, K
Power

110 VAC ±10% (50 / 60 Hz)
2300 Watts

Overall Dimensions 302mm x 176mm x 262mm (HxWxD)
Weight 18.7 lbs (8.5kg)

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or