Toll Free: 866-436-2430                     Email: sales@hotektech.com
 
 
Instruments, calibrators, standards, analyzers, dataloggers. analyzers
 
  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

SIMULATOR RESISTANCE DECADE BOX


RTD Series Simulator Resistance Decade.
RTD Series Simulator Resistance Decade is ideal where applications of Resistance Temperature Detector RTD simulation require exact low value resistance without "zero" and contact resistance effects. The RTD-Z-6-.001 exhibits a resistance range of 10
Ω to 1,111.110 Ω, 1 mΩ lowest decade resolution, 50 ppm absolute accuracy. The RTD-Z-6-.01 has a 10 mΩ resolution.
If this simulator is substituted for any RTD, the rest of the system may be calibrated or examined. Special designs virtually eliminate zero resistance and switch contact variations, providing the specified absolute accuracy over the entire range.
See the PZS Series for computer controlled RTD instruments. 
For handheld and field use, consider the ohmSource Series.

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
  • 50 ppm absolute accuracy

  • 1 mΩ resolution

  • No “zero” resistance; direct setting

  • Highest performance RTD simulator available

  • Highest accuracy, highest stability, lowest TC

  • wide range - 10 Ω to 1111.110Ω

  • Virtually independent of contact resistance variation

  • Ideal for DIN PT-100, PT-100 ANSI, PT-50 and NI-120 systems

  RTD-Z-6-.001 RTD-X-6-.001 RTD-Z-6-.01 RTD-X-6-.01 RTD-250

Minimum resistance (Ohm)
Maximum resistance (Ohm)
Resolution (m)
Number of decades
Absolute accuracy (ppm)
Tempco max. (ppm/
°C)
Tempco typical (ppm/
°C)
Stability (ppm/24hrs)
Stability (ppm/year)
for rated accuracy (mA)
Maximum power (mW)
Maximum current (mA)
Dimensions W cm (in)
H cm (in)
D cm (in)

10.000
1,111.110
1
6
50
5
3
2
10
80
100
200
43.9(17.3)
8.9(3.5)
10.2(4)

10.000
1,111.110
1
6
100
5
3
2
10
100
100
220
43.9(17.3)
8.9(3.5)
10.2(4)

100.00
11,111.10
10
6
50
5
3
2
10
80
100
200
43.9(17.3)
8.9(3.5)
10.2(4)

100.00
11,111.10
10
6
100
5
3
2
10
100
100
220
43.9(17.3)
8.9(3.5)
10.2(4)

20.00
1,121.10
10
5
200
5
3
2
10
150
100
220
30.9(12.2)
8.9(3.5)
10.2(4)

RTD-Z-6-.001 High Accuracy RTD Simulator, 1,111 , 1 m resolution, 50 ppm accuracy
RTD-X-6-.001 High Accuracy RTD Simulator, 1,111 , 1m resolution, 100 ppm accuracy
RTD-Z-6-.01 High Accuracy RTD Simulator, 11,111 , 10 m resolution, 50 ppm accuracy
RTD-X-6-.01 High Accuracy RTD Simulator, 11,111 , 10 m resolution, 100 ppm accuracy
RTD-250 RTD Simulator, 1,121 , 10 m resolution, 0.02% accuracy

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.