  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

HARS RESISTANCE DECADE BOX


HARS Resistance Decade Box. Standard Resistor Decade.
HARS Series Resistance Resistor Decade is the best choice when you need a laboratory grade, tight tolerance, high performance resistance decade box that is also cost effective.
Zero Resistance: <1 m per decade, at dc; slightly higher for 7-10 decades.
Maximum Voltage to Case: 2000 V peak.
Switch Type: 11 positions; "0"-"10"; multiple solid silver alloy contacts.
Switch Capacitance: <4 pF per switch, low loss.
Terminals: Low thermal emf beryllium copper binding posts with standard 3/4 inch spacing plus shield terminal; connections from the rear of the instrument are available with RO option. 
Solderable terminals for single decade units.

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
  • Resistance from 1 mΩ to 111 MΩ

  • Excellent stability - 10 ppm/yr, 25 ppm/ 3 yrs

  • Wide choice - single through 11 decade units

  • High accuracy - 0.01% (100 ppm)

    • HARS-Z: ±(50 ppm + 1 mΩ)

    • HARS-X: ±(0.01% + 2 mΩ)

    • HARS-A: ±(0.05% + 2 mΩ)

    • HARS-Q: ±(0.02% + 2 mΩ)

    • HARS-B: ±(0.1% + 4 mΩ)

  • Very low zero resistance: <1 mΩ per decade

  • High performance solid silver alloy switches

  • Low temperature coefficient - 5 ppm/°C

  • Noninductive or low inductance resistors

  • Rack mounting available

  • Special and custom configurations available

Single decade units are available with resistance as low as 1 milliOhm per step to as high as 10 MOhm per step. 
These units satisfy many system applications requiring only a single decade while maintaining all the quality features of the
HARS series.
Each decade is enclosed in an aluminum case which can serve as a shield.
It may be panel mounted and integrated with additional units to form potentiometer circuits or other configurations. 
Each unit consists of low inductance resistors in series, with a high performance
solid silver alloy contact switch.

Model*
(0.01% Accuracy)

Total Res.
(Ohm )

No. of
Decades

Resolution
(Ohm )

HARS-X-1-0.001
HARS-X-1-0.01
HARS-X-1-0.1
HARS-X-1-1
HARS-X-1-10
HARS-X-1-100
HARS-X-1-1K
HARS-X-1-10K
HARS-X-1-100K
HARS-X-1-1M
HARS-X-1-10M

0.01
0.1
1
10
100
1 k
10 k
100 k
1 M
10 M
100 M

1
1
1
1
1
1
1
1
1
1
1

0.001
0.01
0.1
1
10
100
1 k
10 k
100 k
1 M
10 M

HARS-X-2-0.001
HARS-X-2-0.01
HARS-X-2-0.1
HARS-X-2-1
HARS-X-2-10
HARS-X-2-100
HARS-X-2-1K
HARS-X-2-10K
HARS-X-2-100K
HARS-X-2-1M

0.11
1.1
11
110
1.1 k
11 k
110 k
1.1 M
11 M
110 M

2
2
2
2
2
2
2
2
2
2

0.001
0.01
0.1
1
10
100
1 k
10 k
100 k
1 M

HARS-X-3-0.001
HARS-X-3-0.01
HARS-X-3-0.1
HARS-X-3-1
HARS-X-3-10
HARS-X-3-100
HARS-X-3-1K
HARS-X-3-10K
HARS-X-3-100K

1.11
11.1
111
1.11 k
11.1 k
111 k
1.11 M
11.1 M
111 M

3
3
3
3
3
3
3
3
3

0.001
0.01
0.1
1
10
100
1 k
10 k
100 k

HARS-X-4-0.001
HARS-X-4-0.01
HARS-X-4-0.1
HARS-X-4-1

11.11
111.1
1.111 k
11.11 k

4
4
4
4

0.001
0.01
0.1
1

HARS-X-4-10
HARS-X-4-100
HARS-X-4-1K
HARS-X-4-10K

111.1 k
1.111 M
11.11 M
111.1 M

4
4
4
4

10
100
1 k
10 k

HARS-X-5-0.001
HARS-X-5-0.01
HARS-X-5-0.1
HARS-X-5-1
HARS-X-5-10
HARS-X-5-100
HARS-X-5-1K

111.11
1.1111 k
11.111 k
111.11 k
1.1111 M
11.111 M
111.11 M

5
5
5
5
5
5
5

0.001
0.01
0.1
1
10
100
1 k

HARS-X-6-0.001
HARS-X-6-0.01
HARS-X-6-0.1
HARS-X-6-1
HARS-X-6-10
HARS-X-6-100

1.111 11 k
11.1111 k
111.111 k
1.111 11 M
11.1111 M
111.111 M

6
6
6
6
6
6

0.001
0.01
0.1
1
10
100

HARS-X-7-0.001
HARS-X-7-0.01
HARS-X-7-0.1
HARS-X-7-1
HARS-X-7-10

11.111 11 k
111.1111 k
1.111 111 M
11.111 11 M
111.1111 M

7
7
7
7
7

0.001
0.01
0.1
1
10

HARS-X-8-0.001
HARS-X-8-0.01
HARS-X-8-0.1
HARS-X-8-1

111.111 11 k
1.111 111 1 M
11.111 111 M
111.111 11 M

8
8
8
8

0.001
0.01
0.1
1

HARS-X-9-0.001
HARS-X-9-0.01
HARS-X-9-0.1

1.111 111 11 M
11.111 111 1 M
111.111 111 M

9
9
9

0.001
0.01
0.1

HARS-X-10-0.001
HARS-X-10-0.01

11.111 111 11 M
111.111 111 1 M

10
10

0.001
0.01

HARS-X-11-0.001 111.111 111 11 M 11 0.001

* For less exacting applications, more economical tolerances are available:
- use "A" for "X" in part number for 0.05% basic accuracy, in lieu of .01%
- use "Q" for "X" in part number for 0.02% basic accuracy, in lieu of .01%
- use "B" for "X" in part number for 0.1% basic accuracy, in lieu of .01%

OPTIONS
- RM
Rack mountable case for standard 19" rack
- K Kelvin type 4-terminal binding posts
- RO Rear output binding posts

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.