Toll Free: 866-436-2430                     Email: sales@hotektech.com
 
 
Instruments, calibrators, standards, analyzers, dataloggers. analyzers
 
  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

SR1030 RESISTANCE TRANSFER STANDARDS


SR1030 Resistance transfer standard. Values 1Ω , 10Ω , 100Ω , 1 KΩ , 10 KΩ  and 100 KΩ
SR1030 Resistance transfer standards consist of 12 equal steps.
These steps are available in increments of 1 ohm (SR1030-1), 10 ohms (SR1030-10), 100 ohms (SR1030-100), 1kohms (SR1030-1k), 10kohms (SR1030-10k) and 100kohms (SR1030-100k).
The Model SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The SR1010 and SR1030 are used for the same applications and are alike in configuration. The SR1030 differs from the SR1010 in that it is specially sealed, and values below 100KW are filled with oil to improve changes due to thermal variations.

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
  • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM

  • Transfer Accuracy... ± (1PPM + 0.1µΩ at parallel value) for 100:1

  • Transfer Accuracy... ± (1PPM + 1µΩ at series parallel value) for 10:1

  • Long Term Accuracy... ± 50PPM of nominal value

  • Calibration Accuracy... ± 10PPM

  • 1 year warranty

APPLICATIONS:
Calibration of Working Standards and Precision Resistance Measuring Systems
Reference Voltage Divider
Used to transfer NIST traceability to different values of Resistance

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [Top] [Distribution] [Contact Us]