FAST SLEW RATE ELECTRONIC LOADS
ELL-355 Fast Slew Rate Low Voltage Electronic Load

ELL-355 Fast Slew Rate, Low Voltage Electronic Load. Voltage 30V, Current 135A,
The ELL-355 is well adapted to R&D application for power supplies and power devices having faster operational speed, lower voltage and large output current.
Slew rate of up to 50A/uS is realized by reducing the internal parasitic impedance.
Excellent current waveforms having little overshoot and falling edges are independently set from the front panel as well as program.
Constant Current (CC), Constant Resistance (CR), Constant Power (CP), External Control, Dynamic Sequence, Short and Current Limit

  • Loading power can be expanded by parallel operation (Booster function).

  • Expanded Operation Range by Peak Power and Low Voltage Operation mode.

  •  Adjustable fast slew rate operation up to 50A/uS.

  • High Current of 135A max.

  • Sequence mode up to 1024 steps

  • Current Monitor and TRIG OUT as standard

  •  Standard GPIB & USB interfaces

  • Memory functions (Measurement range and
    setting conditions)

  • Dynamic mode : Up to 16 combinations of any current & Time can be set.

  • Ripple & Noise measurement (Factory option)

Peak Power
Newly invented "Extreme Power" technology (patent pending) allows ELL-355 to operate at much higher power for the duration specified since this technology manages Peak Power and Average Power.
This unique feature is best suite to such as Over Current Testing of DC Power Supplies at higher
current rate for short duration.
Low Voltage Operation.
There is no operating limitation by Loading Voltage since ELL-354 sinks load current as far as voltage difference exists.

The ELL-355 is equipped with various features suitable for evaluation and inspection applications. External control mode (0 - 10V) can control load current externally, Current monitor for load current monitoring (not isolated), GPIB as well as USB interface.

SPECIFICATION

Load Section

Max rating
Current 135A
Voltage 30V
internal min resistance 3m ohm
Min operating voltage(*6) 0.4V(135A) / 0.2V(67.5A) / 0.1V(33.75A)
Peak power(*5) 4000W (20us or less)
430W(20s or less)
Rated power 350W
    CC mode
Current range 15A 135A
Setting range 0 - 15A 0 - 135A
Nominal resolution(*1) 1mA 10mA
Accuracy +/- 0.2% of stg. +/- 15mA +/- 0.2% of stg. +/- 60mA
    CR mode
Voltage range 4V
Current range 15A 135A
Current range
(Setting range)
0.05 - 500 ohm 5m - 50 ohm
Nominal resolution(*1) 2ms 20ms
Accuracy(*2) +/- 0.5% of Conv. Curr. +/- 0.2% of f.s.
 
Voltage range 30V
Current range 15A 135A
Current range
(Setting range)
0.15 - 1500 ohm 0.015 - 150 ohm
Nominal resolution(*1) 666us 6.66ms
Accuracy(*2) +/- 0.5% of Conv. Curr. +/- 0.2% of f.s.
    CV mode
Voltage range 4V 30V
Setting range 0 - 4V 0 - 30V
Nominal resolution(*1) 0.5mV 5mV
Accuracy +/- 0.2% of stg. +/- 0.2% of f.s.
Response time Fast/Slow (300us/10ms)
    CP mode
Current range 15A 135A
Power range
(Setting range)
0 - 40W 0 - 350W
Nominal resolution(*1) 5mW 25mW
Accuracy +/- 2.5% of stg. +/- 1% of f.s.
    External control mode
Current range 15A 135A
Setting range 0 - 15A 0 - 135A
Nominal resolution(*1) 2mA 20mA
Accuracy(*4) +/- 0.2% of stg. +/- 0.5% of f.s.
Control voltage 0 - 10V
    Dynamic mode
   Dynamic mode
Current range 15A 135A
Control method Switching
Loading mode CC mode
Setting Period 2us - 100ms / 200ms / 500ms / 1.0s
Period resolution 1us / 5us / 10us / 50us
Operating mode Continuous, Single
Slew rate 0.05 - 5A/us 0.5 - 50A/us
Min load response time(*3) 500ns
 
   Sequence mode
Loading mode CC / CR / CV / CP mode
Max steps 1024
Step duration 1ms - 10min
Step duration resolution 1ms(1ms - 100ms) / 100ms(100ms - 10min)
    Short mode
Short current (MAX) 135A
    Current limit setting
Current range 15A 135A
Setting range 0.1 - 15A 1 - 135A
Nominal resolution(*1) 100mA 1A
    Parallel operation
Master-Slave operation. One master unit can control up to 4 units of slaves of same voltage rating. For example: If the master unit is ELA-305 then ELA-155, ELA-305 or ELA-1005 may be connected as slave unit.

*1 : Nominal resolution: Approximated resolution of the range.
*2 : Conv.Curr: Ideal current value being calculated by [input / set R]
*3 : Min load response time: Minimum time required by the load when setting slew rate.
*4 : Rin: ELA-155 : 100kohm(typ) ELB-155 : 200kohm(typ) ELC-155 : 1500kohm(typ)
*5 : External control setting accuracy: Setting accuracy is defined when external control
      voltage of 10V is fed.
*6 Setting accuracy in CR mode is valid when applied 10% or more voltage of the voltage range.
*7 : It may vary in accordance to the internal temperature.
*8 : Minimum operating voltage vary according to the current value.
*9 : At rear loading terminals.

Measuring Section

 DC Voltage
Range 4.0000V 30.000V
Resolution 0.1mV 1.0mV
Accuracy(*1) +/- 0.05% of rdg. +/- 0.05% of f.s.
Measuring time(*2) Approx. 100ms
    DC current
Range(*3) 15.0000A 135.000A
Resolution 0.1mA 1mA
Accuracy(*1) +/- 0.2% of rdg. +/- 0.2% of f.s.
    Power
Measuring method(*4) By calculation [Voltage X Current]
Measuring time(*2) Approx. 200ms

 

General

  General
Loading terminals On front panel and rear panel
Rated power requirement AC100 - 240V+/- 10% 50/60Hz
Power consumption 45VA or less (when in AC100V)
Operating temperature 5 - 40C
Cooling system Forced cooling fan
Dimensions 215(W) X 128.6(H) X 420(D) excluding projected part
Weight Approx. 10Kg
    Interface
GPIB Conforming to IEEE488.1
USB Conforming to USB1.1
External control voltage 0 - 10V
    Protection, Alarm
Over current protection Protect load section by limiting the current
Over power protection Protect load section by limiting the power
Over voltage alarm Generate alarm when over voltage is applied
Temperature protector Generate alarm and cut off the output when overheated
Reverse connection alarm Generate alarm when reverse voltage is applied

* Noted that the alarm function does not protect the instrument.
Remove the cause of alarm to protect the instrument.

TRIG OUT
Output(*1) Photo coupler output
Output voltage CC1 +5V (Typ)
CC2 - CC16 0V (Typ)
    CURRENT MONITOR
Output(*2) 1V / 135A f.s.
Output resistance 50 ohm
Accuracy(*3) +/- 1% of Conv.Volt. +/- 1% of f.s.

*1 TRIG OUT: Isolated
*2 CURRENT MONITOR: Not isolated
*3 Full scale of the current monitor and rated current are different in current range High, Mid and Low.

 

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.