All ProductsAnalyticalAnalyzersCalibratorsHumidityData LoggersLight MetersMeasurement

 

MultimetersOhmmetersPressureStandardsTemperatureTransmitters

POWER SUPPLY TEST SYSTEM
PW-600 Automatic Switching Power Supply Test System

PW-600E DC Power Supply Tester
PW-600E DC Power Supply Tester would provide less expensive ,fast Speed .Thanks to USB control. Much faster testing time can be provided than any other GPIB Systems.
Features

  • Fast Testing Time

  • Accurate p-p Ripple Noise Measurement Capability (50MHz)

  • Easy Editing & Testing Operations

  • Input Voltage Setup (AC or DC)

  • Load Setup (CC or CR Mode)

  • Output Volt. Measurement (DC V DC Current p-p Ripple Noise, p-p Ripple)

  • Input Measurement (Voltage, Current, Power Efficiency, Power Factor)

  • Sequence (rise time, fall time, hold time)

  • Operating/Shortage Voltage

  • Over Voltage Protection Test (Auto/Manual Mode)

  • Over Current Protection Test

  • Inrush Current Measurement

  • Output Voltage Adjustment

  • Contactor Control

  • Digital I/O Control

  • Load Regulation*

  • line Regulation*

  • Cross Regulation*

  • Over Current Protection Adjustment

  • DMM Measurement

PW-600E would provide less expensive ,fast Speed .Thanks to USB control, 
Much faster testing time can be provided than any other GPIB Systems. 
SC-816 Remote Box

For your easy testing operations, Remote Box allows you to operate PW-600E fast and accuracy. 
Print Mode and NG Stop Mode etc. can be setup. 
Emergency STOP Button and Print Mode Switches are also located on it.


Specifications

Output Measurement Section
DCV Measurement  
Range +-5.999V +-29.999V +-99.996V
Resolution 1mV 1mV 4mV
Accuracy(* 1)

+-0.05% of rdg. +-0.05% of f.s.

Input Impedance 1MOhm
Max. Applied Volt. +-100V (DC)
DC Current Measurement
Channel No. 1CH 2CH 3CH 4CH 5CH
Range 50A 20A 20A 10A 10A
Resolution 2mA 0.8mA 0.8mA 0.4mA 0.4mA
Accuracy(*1) +-1% of rdg. +-0.5% of f.s.

 

Ripple Noise measurement
Range 199.9mV 1999mV
Resolution 0.1mV 1mV
Accuracy(*1) +-2% of rdg. +-2% of f.s.
Nominal Bandwidth 50MHz
Input Impedance 50Ohm(Hi Frequency)
Ripple Noise Ratio 0% - 15%

 

Load Unit
Channel No. 1CH 2CH 3CH 4CH 5CH
HIGH Range 50A 20A 20A 10A 10A
LOW Range 5A 2A 2A 1A 1A
Resolution 1/1000 of Each Range
Setup Accuracy +-0.5% of stg. +-0.1% of f.s. (HIGH Range)
Resistance Setup  
LOW Range 0.1-1Ohm 0.25-2.5Ohm 0.25-2.5Ohm 0.5-5Ohm 0.5-5Ohm
HIGH Range 1-100Ohm 2.5-250Ohm 2.5-250Ohm 5-500Ohm 5-500Ohm
Resolution 1mOhm-50Ohm 2.5mOhm-125Ohm 2.5mOhm-125Ohm 5mOhm-250Ohm 5mOhm-250Ohm
Setup Accuracy +-5%(when Min. Resistance is setup

 

DC Source Over Voltage Test
Setup Range 0 - 70V
LOW/HIGH Range 0-50V/50-70V
Setup Accuracy +-0.5% of stg.+- 0.5% of f.S.
Output Current 0 - 0.5A
Scanner section (Standard Portion)
Remote Box I/F
+12V CMOS Input

8 Circuits

Open Collector

4Circuits

OV Scanner
No. of Output Channels

8

Rated of Relays

70V, 0.5A

DVM Multiplexer(*2)
No. of Input Channels

16

Rated of Relays

100V DC

Digital I/O
Input Circuit type Photo Coupler Isolated Input (Input Impedance1kOhm)
No. of Input Circuits

8

Output Circuit Type

Photo Coupler Isolated Open Collector Output

No. of Output Circuits

8

 

Scanner Section (Optional Cards)
DVM Multiplexer Card (*2)

SC-830 

No. of Input Channels

8

Rated of Relays

100V DC

Max. No. of additional Card

2

User's Contact Relay Card

SC-840

Relay Type

Mechanical Contact Relays

No .of Relays

8

Rated of Relays

30V 1A (DC) / 250V 1A (AC)

Max. No. of additional Card

4

Digital‚h/‚n Card

SC-850

Input Circuit Type Photo Coupler Isolated Input (Input resistance 1KOhm)
No. of Input Circuits

8

Output Circuit Type

Photo Coupler Isolated Open Collector Output

No. Output Circuits

8

Max. No. of additional Card

3

Sequence Meas. Card

SC-860

No. of Meas. Channel

3

Max. Applied Volt.

+-150V

Input Impedance

1MOhm

Threshold

Setup Volt. Range +-50V

Measurement Clock

0.1mS

Mx. Measurement Time

0-3S

Max. No. of additional Card

4

 

model-512P AC Source Section
Measurement Section
AC Volt. Meas. Range 300V
Accuracy +-0.5% of rdg +-0.2% of f.s
Resolution 0.1V
AC Curr. Meas. Range 10A 1A
Accuracy1(*1)(*3)(*4) +-0.5% of rdg +-0.2% of f.s +-1.0% of rdg +-0.5% of f.s
Resolution 1mA
Effective Power Meas. Range 1000W 100W
Accuracy1 (*1)(*3) +-0.5% of rdg +-0.2% of f.s +-0.5% of rdg +-0.2% of f.s
Resolution 0.1W
AC Power Section

Frequency 40Hz / 80Hz +-1.0%
Output Volt. Range 100V Range 300V Range
Output Volt. Range(*5) 0-150V 10 - 290 V
Output Voltage Setup Resolution 0.15V
Accuracy of Output Volt. +-1.0 V +- 2.0 V
Max. Output Curr. 10Arms 5 Arms
Transient Max. Output Curr. 40Apeak 20Apeak
Input Power Factor 0.9
Efficiency 70% or more
Protection Circuits Output is cut when some abnormal issues in a device or overheat is detected. ; Output is suppressed when over current or over power loss in a device is detected; Output is cut when output is shortened

 

model-513 DC Source Controller

This Unit can control DC Source for DC/DC Converter Testing . Because of FET Switch inside, Inrush Current as well as Input Current can be measured.

 

SW-100 AC Power Switch Unit

This unit can be used as Switching Unit for Inrush Current Measurement of AC Input.

 

General
  model-500E model-512P model-513 SW-100
Input Power AC90V-110V 50Hz,60Hz
Consumption Power less than 200VA less than 2KVA less than 10VA less than 40VA
Dimensions 432(W)200(H)500(D) 432(W)200(H)500(D) 136.5(W)140(H)265(D) 430(W)100(H)400(D)
Weight less than 15kg less than 20kg less than 3kg less than10kg

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [Top] [Distribution] [Contact Us]