POWER
SUPPLY TEST SYSTEM |
|
|
PW-600 Automatic Switching Power Supply Test System |
|
PW-600E
DC Power Supply Tester
PW-600E DC Power Supply
Tester would provide less
expensive ,fast Speed .Thanks to USB control. Much faster testing time
can be provided than any other GPIB Systems.
Features
|
 |
-
Input Voltage Setup (AC
or DC)
-
Load Setup (CC or CR
Mode)
-
Output Volt. Measurement
(DC V DC Current p-p Ripple Noise, p-p Ripple)
-
Input Measurement
(Voltage, Current, Power Efficiency, Power Factor)
-
Sequence (rise time,
fall time, hold time)
-
Operating/Shortage
Voltage
-
Over Voltage Protection
Test (Auto/Manual Mode)
-
Over Current Protection
Test
-
Inrush Current
Measurement
|
|
|
|
|
|
|
PW-600E
would provide less expensive ,fast Speed .Thanks to USB control,
Much
faster testing time can be provided than any other GPIB Systems. |
| SC-816
Remote Box |
 |
For your easy testing operations,
Remote Box allows you to operate PW-600E fast and accuracy.
Print Mode
and NG Stop Mode etc. can be setup.
Emergency STOP Button and Print
Mode Switches are also located on it.
|
Specifications
|
Output
Measurement Section
| DCV Measurement |
|
| Range |
+-5.999V |
+-29.999V |
+-99.996V |
| Resolution |
1mV |
1mV |
4mV |
| Accuracy(* 1) |
+-0.05%
of rdg. +-0.05% of f.s.
|
| Input Impedance |
1MOhm |
| Max. Applied
Volt. |
+-100V
(DC) |
|
DC
Current Measurement
| Channel No. |
1CH |
2CH |
3CH |
4CH |
5CH |
| Range |
50A |
20A |
20A |
10A |
10A |
| Resolution |
2mA |
0.8mA |
0.8mA |
0.4mA |
0.4mA |
| Accuracy(*1) |
+-1%
of rdg. +-0.5% of f.s. |
|
Ripple
Noise
measurement
| Range |
199.9mV |
1999mV |
| Resolution |
0.1mV |
1mV |
| Accuracy(*1) |
+-2%
of rdg. +-2% of f.s. |
| Nominal Bandwidth |
50MHz |
| Input Impedance |
50Ohm(Hi
Frequency) |
| Ripple Noise Ratio |
0%
- 15% |
|
Load Unit
| Channel No. |
1CH |
2CH |
3CH |
4CH |
5CH |
| HIGH Range |
50A |
20A |
20A |
10A |
10A |
| LOW Range |
5A |
2A |
2A |
1A |
1A |
| Resolution |
1/1000
of Each Range |
| Setup Accuracy |
+-0.5%
of stg. +-0.1% of f.s. (HIGH Range) |
| Resistance Setup |
|
| LOW Range |
0.1-1Ohm |
0.25-2.5Ohm |
0.25-2.5Ohm |
0.5-5Ohm |
0.5-5Ohm |
| HIGH Range |
1-100Ohm |
2.5-250Ohm |
2.5-250Ohm |
5-500Ohm |
5-500Ohm |
| Resolution |
1mOhm-50Ohm |
2.5mOhm-125Ohm |
2.5mOhm-125Ohm |
5mOhm-250Ohm |
5mOhm-250Ohm |
| Setup Accuracy |
+-5%(when
Min. Resistance is setup |
|
DC Source Over Voltage Test
|
Setup
Range |
0
- 70V |
|
LOW/HIGH
Range |
0-50V/50-70V |
|
Setup
Accuracy |
+-0.5%
of stg.+- 0.5% of f.S. |
|
Output
Current |
0
- 0.5A |
|
Scanner section (Standard Portion)
|
Remote Box I/F |
|
|
+12V CMOS Input |
8 Circuits
|
| Open Collector |
4Circuits
|
|
OV Scanner |
|
|
No. of Output Channels |
8
|
|
Rated of Relays |
70V, 0.5A
|
|
DVM Multiplexer(*2) |
|
|
No. of Input Channels |
16
|
|
Rated of Relays |
100V DC
|
|
Digital I/O |
|
| Input Circuit type |
Photo Coupler Isolated Input (Input
Impedance1kOhm) |
|
No. of Input Circuits |
8
|
|
Output Circuit Type |
Photo
Coupler Isolated Open Collector Output
|
|
No. of Output Circuits |
8
|
|
Scanner Section (Optional Cards)
|
DVM Multiplexer
Card (*2) |
SC-830
|
|
No. of Input Channels |
8
|
|
Rated of Relays |
100V DC
|
|
Max. No. of additional
Card |
2
|
|
User's Contact
Relay Card |
SC-840
|
|
Relay Type |
Mechanical
Contact Relays
|
|
No .of Relays |
8
|
|
Rated of Relays |
30V 1A
(DC) / 250V 1A (AC)
|
|
Max. No. of additional
Card |
4
|
|
Digital‚h/‚n
Card |
SC-850
|
|
Input Circuit Type |
Photo
Coupler Isolated Input (Input resistance 1KOhm) |
|
No. of Input Circuits |
8
|
|
Output Circuit Type |
Photo
Coupler Isolated Open Collector Output
|
|
No. Output Circuits |
8
|
|
Max. No. of additional
Card |
3
|
|
Sequence Meas.
Card |
SC-860
|
|
No. of Meas. Channel |
3
|
|
Max. Applied Volt. |
+-150V
|
|
Input Impedance |
1MOhm
|
|
Threshold |
Setup
Volt. Range +-50V
|
|
Measurement Clock |
0.1mS
|
|
Mx. Measurement Time |
0-3S
|
|
Max. No. of additional
Card |
4
|
|
model-512P AC Source Section
|
Measurement
Section |
|
|
AC Volt. Meas. Range |
300V |
|
Accuracy |
+-0.5%
of rdg +-0.2% of f.s |
|
Resolution |
0.1V |
|
AC Curr. Meas. Range |
10A |
1A |
|
Accuracy1(*1)(*3)(*4) |
+-0.5%
of rdg +-0.2% of f.s |
+-1.0%
of rdg +-0.5% of f.s |
|
Resolution |
1mA |
|
Effective Power Meas.
Range |
1000W |
100W |
|
Accuracy1 (*1)(*3) |
+-0.5%
of rdg +-0.2% of f.s |
+-0.5%
of rdg +-0.2% of f.s |
|
Resolution |
0.1W |
|
AC Power
Section |
|
|
Frequency |
40Hz /
80Hz +-1.0% |
|
Output Volt. Range |
100V
Range |
300V
Range |
|
Output Volt. Range(*5) |
0-150V |
10 - 290
V |
|
Output Voltage Setup
Resolution |
0.15V |
|
Accuracy of Output
Volt. |
+-1.0
V |
+- 2.0 V |
|
Max. Output Curr. |
10Arms |
5 Arms |
|
Transient Max. Output
Curr. |
40Apeak |
20Apeak |
|
Input Power Factor |
0.9 |
|
Efficiency |
70%
or more |
|
Protection Circuits |
Output
is cut when some abnormal issues in a device or overheat is
detected. ; Output is suppressed when over current or over
power loss in a device is detected; Output is cut when output
is shortened |
|
 |
model-513 DC Source Controller
This Unit can control DC Source
for DC/DC Converter Testing . Because of FET Switch inside, Inrush
Current as well as Input Current can be measured.
|
|
 |
SW-100 AC Power Switch Unit
This unit can be used as
Switching Unit for Inrush Current Measurement of AC Input.
|
|
General
| |
model-500E |
model-512P |
model-513 |
SW-100 |
| Input Power |
AC90V-110V 50Hz,60Hz |
| Consumption Power |
less than 200VA |
less than 2KVA |
less than 10VA |
less than 40VA |
| Dimensions |
432(W)200(H)500(D) |
432(W)200(H)500(D) |
136.5(W)140(H)265(D) |
430(W)100(H)400(D) |
| Weight |
less than 15kg |
less than 20kg |
less than 3kg |