RIPPLE NOISE METER
RM-103 Ripple Noise Meter

RM-103 AC Ripple Noise Meter
RM-103 Ripple Noise Meter which can measure p-p Ripple Noise, p-p Noise of Switching Power Supply by digital Measurement. (up to 100MHz).

Ripple Noise or Noise Measurement has been though as trouble making, because Oscilloscope won't detect peak of Ripple Noise or Measured data may be changed if an Operator read such data with an Oscilloscope. Actually some noise measurement tools are available but these never covers faster Ripple and Noise more than 50MHz. Using narrow band tool makes no sense for high speed noise which can gave undesired effect for equipments.

  • AC Ripple Noise and Switching Ripple
    can be measured independently.

  • Human reading errors can be completely eliminated.

  • Only one Ripple Noise Meter which
    conforms to the Standard of EIAJ ,
    Electronic Industries Association of Japan

  • Ripple Noise Meter can measure faster
    noise up to 100MHz

  • Automatic Ripple Ratio* Selection Function
    *:Ripple Ratio is Parameter to measure
    p-p Ripple Noise accurately

New Automated Measurement method

Now you can terminate such trouble completely. RM-103 can measure p-p Ripple Noise and p-p Noise accurately and automatically by GPIB and manually. 
With SC-82 Scanner, Multiple Input up to 16 channel can be applied . 
You can select Input channel of SC-82 via RM-103 by GPIB for p-p Ripple Noise and p-p Noise measurement.
Also you can add DP-100 Differential Probe to eliminate Common Mode Noise.
Of course all these family covers wide band range up to 100MHz

Specifications

DC Volt. Measurement
Range +-6.0000V +-60.000V +-500.00V
Resolution 0.1mV 1.0mV 10.0mV
Accuracy(*5) +-0.025% of rdg. +-0.025% of f.s.
Max. Applied Volt. +-500V
Measurement Time less than 90ms(Fast Mode)/less than250ms(Slow Mode)
Ripple Noise Measurement
Ranges 300.0mVp-p 3000mVp-p
Resolution 0.1mV 1.0mV
Accuracy(*1, *2, *3 ) +-2% of rdg. +-1% of f.s.
Nominal Bandwidth 100MHz
LF Bandwidth 50Hz - 2KHz
HF Bandwidth 2KHz-
THRU Bandwidth 50Hz-100MHz
Band Pass Filter 20MHz
Ripple Ratio (*3)  0.0% - 50% (Resolution 0.5%)
Measurement Time 
(*3, *4 )
approx.170ms (TYP)
Allowed Input 4Vp-p
Input Condition 
Impedance DC:1MOhm,High Frequency :50Ohm
Input Cable 50Ohm Signal Cable RG-58/Differential Probe DP-100
Interface
GP-IB Conform to IEEE488-1987 
PASS/FAIL Judgment Photo Coupler Output same Common (14 pin Connector)
Start Trigger Photo Coupler Input same Common (14 pin Connector)
4CH Output  Photo Coupler Output forSC-81 Control
Input Connector BNC Connector
Other Function Automatic Ripple Noise Ratio Selection Function
General
Input Voltage AC90-264V(50Hz/60Hz)
Consumption Power Weight 20VA approx.1.7kg
Dimensions 180(W)x85(H)x300(D)

 

*1 Effective when Ripple Ratio is setup between 0% and 10%.
*2 Effective when Frequency Range is between 10kHz and 10MHz.
*3 Operates when Frequency Range is between 10kHz and 100MHz.
*4 Measurement Time in the same Measurement Range.