  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

BENCH LABORATORY PROCESS CALIBRATOR STANDARD


3001 Bench Process Calibrator.
The Precision Laboratory Calibrator combines the power and features of a high accuracy lab calibrator, with the addition of an isolated measurement channel.
This isolated measurement channel consists of two (2) voltage ranges: 10V and 100V DC,
current range 0 to 52 mA, Current range with simultaneous 24VDC power, selectable 250 Ohm HART resistor and accuracy of 0.005% of reading on voltage ranges.

BenchProcess Calibrator
Bench Process Calibrator
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Superior calibration accuracy to 0.0025% of reading
Direct keyboard entry or cursor entry with decade control
Automatic standby function protects device under test
Source current, voltage, T/C, RTD (Ohms)
Read T/C, RTD and pressure
Source/read 11 thermocouple types
Source/read nine standard RTD types
Custom RTD/SPRT profile
Nine setpoints for each output range and type
Local or RS232 remote control
IEEE-488 control interface.
Compatible with Fluke Met/Cal® software

Isolated measurement channel
     - Two (2) voltage ranges: 10V and 100 V DC
     - MilliAmp range 0 to 52 mA
     - MilliAmp range with simultaneous 24 VDC power
     - Selectable 250 Ohm HART™ resistor
     - Accuracy of 0.005% of reading on voltage ranges

Bench Process Calibrator General Specifications:

Power Requirements: 90/240 VAC
Remote Interface: RS-232 and GPIB (IEEE488-2 optional)
Circuit Protection: Internal self resetting fuses
Display: 16 x 2 large character alphanumeric with LED backlight
Size: Approx. 11.5” x 4.7” x 12”
Weight: Approx. 5 pounds

 

Function Output Range Input Range Resolution Accuracy ²
(1 Year)
100mV 0 to 100.000mV N/A 1V ± 0.003%, ±3 µV
1V 0 to 1.00000V N/A 10V ± 0.003%, ±10 µV
10V 0 to 10.0000V N/A 100V ± 0.003%, ±100 µV
100V 0 to 100.000V N/A 1mV ± 0.003%, ±1mV
100mA 0 to 100.000mA N/A 1A ± 0.005%, ±1 Count
T/C J,K,T,E,R,
S, N, B, L, U, C, BP, XK, mV
J,K,T,E,R,
S, N, B, L, U, C, BP, XK, mV
Out 0.1 °C/°F
In 0.01 °C/°F
Type J Typical 0.14°C
Type J Typical 0.14°C
RTD PT385 (100, 200, 500, 1000)
PT392, PT3916 (JIS)
Ni120, Cu10, YSI400
PT385 (100, 200, 500, 1000)
PT392, PT3916 (JIS)
Ni120, Cu10, YSI400, 25ohm SPRT
Typical PT385-100
Out 0.1 °C/°F
In 0.001 °C/°F
± 0.10 °C
± 0.020 °C
ohms 5 to 4000.0Ω 0 to 4000.0Ω    
5 to 400.00Ω 0 to 400.00Ω Out 0.001Ω
In 0.001Ω
± 0.05Ω
40 PPM ± 0.002Ω
5 to 4000.0Ω 0 to 4000.0Ω Out 0.01Ω
In 0.01Ω
± 0.3Ω
40 PPM ± 0.02Ω
Pressure 0-1" H2O to 10,000 psi Module
Dependent
0.025% F.S. Typical
Isolated Measurement Channel
  Range Accuracy
  0 - 10.0000 V ± 0.005%, ±0.2 mV
  0 - 100.000 V ± 0.005%, ±2.0 mV
  0 - 52.000 mA ± 0.01%, ± 1 µV
  Loop Power 24 V ± 10%
  HART resistor 250 ± 3%
  Maximum Current 24 mA
Notes:  1) All W/RTD inputs are 4W.
              2) All accuracy specs are "% of reading” unless otherwise noted.