The BetaGauge PIR PRO Reference
Pressure Gauge
provides exceptional performance with ±0.04% of
reading accuracy, especially when operated below 50% of its
range.
The BetaGauge PIR PRO reference pressure gauge is available in
pressure ranges up to 10,000 psig.
Additionally, a compound ranges is also available.
Readings may be displayed in any one of 18 standard engineering
units or in 1 custom user-defined unit to eliminate tedious
conversion calculations.
Rugged zinc-aluminum alloy high pressure cast housing provides
environmental integrity of the gauge in a small, light package.

BetaGauge PIR PRO Reference Class Pressure Gauge
| Model | Description | List Price | Sale Price |
| PIR-PRO | Reference Class Digital Test Gauge. Bottom Mount Style | $968.00 | $909.00 |
| PIR-PRO | Reference Class Digital Test Gauge. Rear Mount Style | $1,043.00 | $980.00 |
| PIR-PRO | Reference Class Digital Test Gauge. 24 VDC Powered Style | $1,043.00 | $980.00 |
The PIR Pro includes a 5-1/2 digit digital display. The
0.65" numerals and companion bar graph provide
an easy to read display, even from a distance. A number of
features provide additional ease of use.
The reading sample rate can be user adjusted to match the
type of measurement required.
Other features include MIN/MAX function, Auto Power Off
and backlight control.
In addition to a ZERO function that compensates for sensor
drift, large residual system pressures
can be nulled using the TARE adjustment.
Standard Engineering Units
PSI, Bar, Kg/cm2, inH2O (4 °C, 20 °C or 60 °F), ft H2O (4
°C, 20 °C or 60 °F), mmH2O,
cmH2O (4 °C and 20 °C), mH2O (4 °C and 20 °C), Kpa, mBAR,
inHg, mmHg, TORR
| Accuracy | Mechanical |
| ±0.04 % FS positive pressure ±0.1 % FS for 1.0 psi |
Dimensions 4.375" x 5.0" x 1.50" |
| Input Pressure Ranges 10” H20*/20 mBAR; 1 psi*/70 mBAR; 15 psi/1 BAR, 30 psi/2 BAR; 100 psi/7 BAR; 300 psi/20 BAR; 500 psi/30 BAR; 1,000 psi/70 BAR; 2,000 psi/140 BAR; 3,000 psi/200 BAR; 5,000 psi/300 BAR; 10,000 psi/700 BAR; 15,000 psi/1035 BAR; -15 to +15 psi*; -15 to +30 psi*; absolute 10, 30, -15 - 300 |
Input Port 1/4" male NPT |
| Display 5 Digits, 0.65" (16.53 mm) height Bar Graph – 0 to 100% in 20 segments |
|
| Temperature Compensation 0 °C to +50 °C (32 °F to +122 °F) to rated accuracy |
Power Battery three (3), size AA alkaline batteries |
| Media Compatibility liquids and gases compatible with 316 stainless steel, 30 C/V range non-corrosive gases and liquids |
Battery Life 1,500 hours without backlight; 2,000 hours at slow sample rate; |
| Environmental Operating Temperature -10 °C to +55 °C Storage -20 °C to +70 °C (-4 °F to +158 °F) |
battery life can be displayed on bar graph to indicate the amount of time left Low Battery Indicator displayed icon near the end of battery life Includes: manual, batteries |