The MC-1010 Process Calibrator
provides the combination of a high accuracy calibrator
and common Multimeter DMM functions.
This Process Calibrator will calibrate virtually any process
device — read and source thermocouples,
RTDs, Ohms, Voltage, current, frequency, pressure and test
continuity as well.
The MC-1010 Process Calibrator is compatible with BETA pressure
modules with the addition of a simple
connector/adapter.
The MC-1010 Multifunction Calibrator features a simple user
interface, large display, and an RS232 interface.

MC1010 Multifunction Process Calibrator
| Model | Description | List Price | Sale Price |
| MC-1010 | Process Calibrator include: Protective Rubber Boot, Test Leads, Batteries, Instruction Manual and NIST Calibration Certificate. |
$1,425.00 | $1,339.00 |
±0.4 °C thermocouple/±0.3 °C RTD accuracy
±0.015% of reading electrical accuracy
Ten (10) T/C types and eight (8) RTD types plus YSI 400
Read and source modes
Full function 4 to 20 mA read, source, simulate, and read/power
modes with ±0.015% of reading accuracy
Source or read 0 to 20 Volts (±0.015% of reading accuracy)
Measure 0 to 250 VDC or VAC
Direct keyboard entry enables quick output changes
Store up to nine (9) setpoints for each output function
RTD function compatible with all pulsed transmitters
| Pressure Ranges | Various ranges in 29 different pressure modules | ||
| T/C Ranges | J, K, T, E, R, S, N, B, L, U including – 10 to 75 mV | ||
| RTD Ranges | Pt 385 (100, 200, 500, 1000 Ohms) Pt 392, JIS, Ni120, Cu10, YSI400 | ||
| Ohms Ranges | 0 to 400.00 and 400 to 3,200 | ||
| mA Range | 0 to 24.000 mA | ||
| Voltage | (Low) Read 0-20.000 VDC Source 0-20.000 VDC (High) Read only 0-250 VDC or VAC |
||
| Frequency | Source | Measure | |
| CPM | 2.0 - 1,000.0 | 0.0 - 1,000.0 | |
| Hz | 0 - 1,000 | 0.0 - 1,000.0 | |
| kHz | 1.0 -10.0 | 0.00 -10.00 | |
| Continuity | 0 to 400.0 Ohms, audible tone when under 10 Ohms | ||
| Accuracy | T/C Type J: ±0.3 °C ±10 mV (±0.4 °C
total error) RTD Pt 100: ±0.1 °C ±.075 Ohm (±0.3 °C total error) Ohms (400): ±0.1Ohm Ohms (3,200): ±1.0 Ohm |
||
| mA Compliance | Up to 1,000 load | ||
| Voltage Drive Capability | 1 mA | ||
| RTD IEX-Range | 0.01 mA to 3 mA | ||
| RTD Frequency Response | 10 ms – works with all pulsed transmitters | ||
| Environmental | Operating Temperature -10 °C to 50 °C Storage Temperature -20 °C to 70 °C |
||
| Power Requirements | 6 VDC Batteries 4 AA alkaline batteries, 25 hours typical operating time | ||
| Mechanical | Dimensions 8.7" H x 4.2" W x 2.3" D
(220.9 x 106.6 x 58.4 mm) Weight 30.5 ounces (863 g) |
||
| Accessories Included | Test leads, 4 x AA alkaline batteries, NIST Certificate, and instruction manual |
||
| Optional Accessories | Carrying Case, Model CC572 | ||