Toll Free: 866-436-2430                     Email: sales@hotektech.com
 
 
Instruments, calibrators, standards, analyzers, dataloggers. analyzers
 
  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

DRY BLOCK CALIBRATOR


T-25N Dry Block Calibrator. Temperature from:  -25ºC to +125ºC (-13ºF to +257ºF).
T-350P Dry Block Calibrator. Temperature from room temperature to 350ºC (662ºF).
T-650P Dry Block Calibrator. Temperature from room temperature to 650ºC (1202ºF). 
T-25N, T-350P and T-650P Dry Block Calibrators perform functions that would require three different types of instruments: dry block, standard thermometer and calibrator for TCs, RTDs, mA, mV, ohms and thermo switches.

 
Dry Block Calibrator
 
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
  • Accomplish completely automatic calibrations with or without the use of a computer.

  • Documenting capabilities: communication with computer and CS-504 Calibration Software.

  • Portable, compact, provide interchangeable inserts and carrying case.

  • Dry Block Calibrator Accuracy up to 0.1ºC with internal reference or 0.05ºC with external thermometer, such as Super Thermometer ST-501.

  • Dry Block Calibrator Resolution of 0.01ºC.

  • Stability of 0.02ºC for T-25N, 0.05ºC for T-350P and T-650P

  • Presents input for thermocouples, thermo resistance and thermo switches.
    Besides generating temperature, they measure the signal from the sensor being calibrated.
    Perform TC readings with high precision internal cold junction compensation.

  • Internal regulated 14VDC power supply and mA input for 2-wire transmitters.

  • Make no use of external standard thermometers.

T-25N, T-350P and T-650P Dry Block Calibrator models control temperature over an insert in order to calibrate thermocouples, thermo resistances, glass thermometers, thermo switches etc. 
Besides providing high accuracy temperature values, they also allow the measurement of signals generated by thermocouples, thermo resistance and thermo switches, which are being calibrated. 
This is possible due to an embedded calibrator specific for these types of signal, including 4-20mA.
They incorporate the functions of dry block, standard thermometer and calibrator for RTD and TC sensors, besides mA reading.

They present a wide variety of programming resources, allowing them to perform automatic calibrations of thermocouples, thermo resistance and thermo switches. In this case, the sensor is placed in the insert and its electrical terminals are connected to the embedded calibrator, the operator defines the calibration points and the number of repetitions, then the process is started so that all the sequence is automatically accomplished. Another way of performing automatic documented calibrations is by means of CS-504 Calibration Software for PC/Windows, which uses RS-232 serial port to connect PC to the dry block. With CS-504 it is possible to register sensors and instruments of the factory, generate work orders, create and print calibration certificates and reports, that is, it brings all advantages of computer data management to the calibration environment.

Dry Block Calibrator Specification

 

T-25N

T-350P

T-650P

Operating Range:
room temperature: 18°C
-25°C to +125°C
(-13°F to +257°F)
from room temperature
up to 350°C
from room temperature
up to 350°C
Accuracy: internal ref
with external thermometer
±0.1°C ±0.1°C ±0.1% of reading ±0.1°C ±0.1% of reading

±0.05°C ( limited by temperature uniformity )

Resolution 0.01°C 0.01°C 0.01°C
Stability ±0.02°C ±0.05°C ±0.05°C
Temperature uniformity

±0.05°C

Weight 8.5kg (18.8lb) 5.8kg (12.8lb) 5.8kg (12.8lb)
Power Supply

110 or 220VAC, 50/60Hz, 200 watts max

Units / Temperature

°C or °F / IPTS-68 or ITS-90 user selectable

Display

Graphic LCD contrast adjustable

Well Diameter / Depth

1" without insert / 125mm

Dimensions

250x180x270mm

Warranty

One year

Electrical Input Specifications
Same as  temperature calibrator TC-502 excluding thermocouples type B, R and S.

Order Code:

T-25N / T-350P / T-650P - [ power supply ] - IN [ insert included ]

Power supply
1 - 110VAC
2 - 220VAC

Insert included
Choose one of the inserts listed below:

Code Example: T-25N-1-IN03, defines a T-25N dry block calibrator with 110VAC power supply,
including insert of type IN03. When not specify, it comes with IN01 insert.
Provided with carrying case technical manual and cables.

Dry Block Calibrator Accessories

Inserts Holes Order code (T-25N / T-350P) Order code (T-650P)
IN01 1x3/4" 06.04.0011-00 06.04.0021-00
IN02 1x1/2" 06.04.0012-00 06.04.0022-00
IN03 1x6.0mm and 3x1/4" 06.04.0013-00 06.04.0023-00
IN04 3x6.0mm and 1x1/4" 06.04.0014-00 06.04.0024-00
IN05 4x6.0mm 06.04.0015-00 06.04.0025-00
IN06 2x6.0mm and 2x1/4" 06.04.0016-00 06.04.0026-00
IN07 1x6.0mm, 1x8.0mm and 1x3/8" 06.04.0017-00 06.04.0027-00
IN08 1x6.0mm, 1x3.0mm and 2x1/4" 06.04.0018-00 06.04.0028-00
IN09 Without hole, blank insert 06.04.0019-00 06.04.0029-00
IN10 Custom insert 06.04.0020-00 06.04.0030-00
Precision temperature sensors Order Code
Probe 1/5 DIN straight - 4 plug connector 04.06.0101-00
Probe 1/5 DIN 90° bend - 4 plug connector 04.06.0102-00
Communication Interface Order Code
RS-232 - 9 way D type connector (COM1) 06.02.1002-00
RS-232 - 25 way D type connector (COM2) 06.02.1004-00
RS-485 06.02.1006-00
Carrying Case 06.01.1006-00
CS-504 Software
Calibration Certificate

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or