DRY BLOCK CALIBRATOR
|
|
|
T-25N Dry Block
Calibrator. Temperature from:
-25ºC to +125ºC (-13ºF to
+257ºF).
T-350P Dry Block Calibrator. Temperature from room temperature to
350ºC (662ºF).
T-650P Dry Block Calibrator. Temperature from room temperature to 650ºC (1202ºF).
T-25N,
T-350P and T-650P Dry Block Calibrators perform functions that would
require three different types of instruments: dry block, standard
thermometer and calibrator for TCs, RTDs, mA, mV, ohms and thermo switches.
|
Dry Block Calibrator
|
| Our
Price: |
Contact us for
pricing |
| Phone:
|
253-927-6186
866-318-6186 |
| Fax:
|
253-927-6189 |
| email:
|
sales@hotektech.com |
|
|
|
|
|
|
|
-
Accomplish completely automatic calibrations
with or without the
use of a computer.
-
Documenting capabilities: communication with computer and CS-504
Calibration Software.
-
Portable, compact, provide interchangeable
inserts and carrying
case.
-
Dry Block Calibrator
Accuracy up to 0.1ºC with internal reference or 0.05ºC with
external thermometer, such as Super Thermometer ST-501.
-
Dry Block Calibrator
Resolution of 0.01ºC.
-
Stability of 0.02ºC for T-25N, 0.05ºC for T-350P
and T-650P
-
Presents input for thermocouples,
thermo resistance and thermo switches.
Besides generating temperature, they measure
the
signal from the sensor being calibrated. Perform TC readings with high
precision internal cold junction compensation.
-
Internal regulated 14VDC power supply and mA input for 2-wire
transmitters.
-
Make no use of external standard thermometers.
|
T-25N,
T-350P and T-650P Dry Block Calibrator models control temperature over an insert in order
to calibrate thermocouples, thermo resistances, glass thermometers, thermo switches
etc.
Besides providing high accuracy temperature
values, they also allow the measurement of signals generated by
thermocouples, thermo resistance and thermo switches, which are being
calibrated.
This is possible due to an embedded calibrator specific
for these types of signal, including 4-20mA.
They incorporate the
functions of dry block, standard thermometer and calibrator for RTD
and TC sensors, besides mA reading.
They
present a wide variety of programming resources, allowing them to
perform automatic calibrations of thermocouples, thermo resistance and thermo switches. In this case, the sensor is placed in the insert and
its electrical terminals are connected to the embedded calibrator, the
operator defines the calibration points and the number of repetitions,
then the process is started so that all the sequence is automatically
accomplished. Another way of performing automatic documented
calibrations is by means of CS-504 Calibration Software for
PC/Windows, which uses RS-232 serial port to connect PC to the dry
block. With CS-504 it is possible to register sensors and instruments
of the factory, generate work orders, create and print calibration
certificates and reports, that is, it brings all advantages of
computer data management to the calibration environment.
|
Dry Block Calibrator Specification
|
| |
T-25N |
T-350P |
T-650P |
Operating Range:
room temperature: 18°C |
-25°C to +125°C
(-13°F to +257°F) |
from room temperature
up to 350°C |
from room temperature
up to 350°C |
Accuracy: internal
ref
with external thermometer |
±0.1°C |
±0.1°C ±0.1% of reading |
±0.1°C ±0.1% of reading |
|
±0.05°C ( limited
by temperature uniformity ) |
| Resolution |
0.01°C |
0.01°C |
0.01°C |
| Stability |
±0.02°C |
±0.05°C |
±0.05°C |
| Temperature uniformity |
±0.05°C |
| Weight |
8.5kg (18.8lb) |
5.8kg (12.8lb) |
5.8kg (12.8lb) |
| Power Supply |
110 or 220VAC,
50/60Hz, 200 watts max |
| Units / Temperature |
°C or °F / IPTS-68
or ITS-90 user selectable |
| Display |
Graphic LCD
contrast adjustable |
| Well Diameter / Depth |
1" without insert
/ 125mm |
| Dimensions |
250x180x270mm |
| Warranty |
One year |
|
|
|
Electrical Input
Specifications
Same as temperature calibrator TC-502 excluding thermocouples
type B, R and S.
Order Code:
T-25N / T-350P / T-650P - [ power supply ] - IN [ insert included ]
Power supply
1 - 110VAC
2 - 220VAC
Insert included
Choose one of the inserts listed below:
|
Code Example:
T-25N-1-IN03, defines a T-25N dry block calibrator with 110VAC power
supply,
including insert of type IN03. When not specify, it comes with IN01
insert.
Provided with carrying case technical manual and cables.
|
Dry Block Calibrator
Accessories
|
| Inserts |
Holes |
Order code (T-25N / T-350P) |
Order code (T-650P) |
| IN01 |
1x3/4" |
06.04.0011-00 |
06.04.0021-00 |
| IN02 |
1x1/2" |
06.04.0012-00 |
06.04.0022-00 |
| IN03 |
1x6.0mm and 3x1/4" |
06.04.0013-00 |
06.04.0023-00 |
| IN04 |
3x6.0mm and 1x1/4" |
06.04.0014-00 |
06.04.0024-00 |
| IN05 |
4x6.0mm |
06.04.0015-00 |
06.04.0025-00 |
| IN06 |
2x6.0mm and 2x1/4" |
06.04.0016-00 |
06.04.0026-00 |
| IN07 |
1x6.0mm, 1x8.0mm and 1x3/8" |
06.04.0017-00 |
06.04.0027-00 |
| IN08 |
1x6.0mm, 1x3.0mm and 2x1/4" |
06.04.0018-00 |
06.04.0028-00 |
| IN09 |
Without hole, blank insert |
06.04.0019-00 |
06.04.0029-00 |
| IN10 |
Custom insert |
06.04.0020-00 |
06.04.0030-00 |
| Precision
temperature sensors |
Order Code |
| Probe 1/5 DIN
straight - 4 plug connector |
04.06.0101-00 |
| Probe 1/5 DIN 90°
bend - 4 plug connector |
04.06.0102-00 |
| Communication
Interface |
Order Code |
| RS-232 - 9 way D
type connector (COM1) |
06.02.1002-00 |
| RS-232 - 25 way D
type connector (COM2) |
06.02.1004-00 |
| RS-485 |
06.02.1006-00 |
| Carrying Case |
06.01.1006-00 |
| CS-504 Software |
| Calibration
Certificate |
|
|
|