GROUND FAULT DETECTOR CLAMP-ON AC CURRENT LEAKAGE DETECTOR  
 
50107-G-01 thru 50107-G-10 Ground Fault Detector Clamp-On AC Current Leakage Detector     
 

50107-G-01 AC Ground Fault Clamp On Current Leakage Detector 1/2/5/10/20/50 Amps Jaw Size 2.5 in.
50107-G-02 AC Ground Fault Current Leakage Detector 1/2/5/10/20/Short Amps Jaw Size 2.5 in.
50107-G-03 AC Ground Fault Clamp On Current Leakage Detector 1/2/5/10/20/50 Amps Jaw Size 3.5 in.
50107-G-04 AC Ground Fault Current Leakage Detector 1/2/5/10/20/Short Amps Jaw Size 3.5 in.
50107-G-05 AC Ground Fault Clamp On Current Leakage Detector 1/2/5/10/20/50 Amps Jaw Size 4.5 in.
50107-G-06 AC Ground Fault Current Leakage Detector 1/2/5/10/20/Short Amps Jaw Size 4.5 in.
50107-G-07 AC Ground Fault Clamp On Current Leakage Detector 1/2/5/10/20/50 Amps Jaw Size 6 in.
50107-G-08 AC Ground Fault Current Leakage Detector 1/2/5/10/20/Short Amps Jaw Size 6 in.
50107-G-09 AC Ground Fault Clamp On Current Leakage Detector 1/2/5/10/20/50 Amps Jaw Size 9 in.
50107-G-10 AC Ground Fault Current Leakage Detector 1/2/5/10/20/Short Amps Jaw Size 9 in.

Photo of Hot Stick Adapter

Ground Fault Detector Current Leakage Detector
 

The unit is used to check cable for leakage 
before major down time is incurred by 
reading the micro amp corona around 
single or 3-phase wiring and on motors up 
close to the peckerhead. 
The unit is also excellent for checking 
splices for leakage.

 

The Ground Fault Detector Clamp On Current Leakage Detector is a great concept in preventative maintenance. 
As insulation ages, it’s insulating properties often deteriorate. 
Humidity and foreign matter aid in this deterioration. 
The current leakage detector will indicate ground faults and electrical leakage while the equipment is in operation. This saves considerable time in making leakage readings, as well as saving operating time.

Photo of Ground Fault Detector
Ground Fault Detector Current Leakage Detector
 

Circuit breakers and fixed current 
monitors are designed to open the circuit or warn of ground faults as they occur. 
They react to failures in the circuit but do not 
indicate their causes. 
The Clamp-on Current Leakage Detector is 
designed to isolate these impeding failures 
before they become serious enough to cause a fire or a costly shutdown. 
Use on a single cable or a bundle.

  • Ideal for preventative maintenance

  • Measures leakage current directly and locates faults

  • Prevents shutdown time

  • Tests without load interruption

  • Operates on single-phase and three-phase networks

  • Clamps easily onto any size conductor (Jaw openings - 3 ½”, 4 ½”, 6”, 9“)

  • Convenient one-hand operation

  • Maximum operating temperature range -5°F to +150°F (-20°C to +65°C)

CATALOG # DESCRIPTION JAW SIZE (IN.)
50107-G-01 1/2/5/10/20/50 Amps 2.5
50107-G-02 1/2/5/10/20/Short Amps 2.5
50107-G-03 1/2/5/10/20/50 Amps 3.5
50107-G-04 1/2/5/10/20/Short Amps 3.5
50107-G-05 1/2/5/10/20/50 Amps 4.5
50107-G-06 1/2/5/10/20/Short Amps 4.5
50107-G-07 1/2/5/10/20/50 Amps 6.0
50107-G-08 1/2/5/10/20/Short Amps 6.0
50107-G-09 1/2/5/10/20/50 Amps 9.0
50107-G-10 1/2/5/10/20/Short Amps 9.0