| DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class C |
|
Frequency of Operation / Frequency Stability |
13.56 MHz default / 0.005%
|
| RF
Power Output |
1200 Watts into 50 Ohm |
|
Gain (as amplifier) in MGC/Burst Mode |
0 dBm IN, 10V CTL IN pin 5 1200W ±12W |
| RF Input Drive
(as amplifier) |
Signal or
function generator, analog computer input capable of up to 2 Vp-p @
50 Ohm |
| RF Input Drive for
AGC |
Recommended
+0 to +3 dBm for the best operation |
Input Drive Source
(amplifier) |
Signal or function generator, analog
computer input capable of up to 2 Vp-p @ 50 Ohm |
- Input and Output
Impedance
|
50 Ohm |
|
Input VSWR |
1.2:1 max |
|
Output VSWR |
3:1 max |
|
Output VSWR Protection |
240 W max reflected power limit.
Automatic foldback limit with [W] level of protection depending on
actual VSWR of a load connected. |
Harmonic level @
550W
|
Better than
- 40 dBc for 2-nd harmonic, any other > -45 dBc |
| Spurious Output |
- 55 dBm
equivalent noise level generated by internal circuits |
|
Output Blanking |
For pulsed applications, our amplifiers
and generators offer blanking of the output signal for minimum noise
RF spectrum |
| Mismatch
Power Output |
Forward Power reference to rating
1:1:1 VSWR, up to 120W,
2:1 load: 120W FWD, 65W LOAD
3:1 load: 60w fwd, 38W LOAD
9:1 load: 32W FWD, 12W LOAD |
|
Dynamic Power Range |
0 to 100W, settings within +/- 2W |
| RF
Output Settings |
-Front Panel EDITOR
-RS 232 port from GUI
-hardware port 1V=100W scale |
|
Pulse Specifications |
Pulse Width: 1 to 500 usec
Period: 1 to 50 milliseconds |
| SWEEP
Operation |
13.3 to 13.8 MHz. Min time 10ms, max
10s.
Settings and activation from GUI only |
|
Power Margin |
28% |
| RF Power
Control |
Front Panel or REmote Power Control via
Hardware Port SubD-25 or RS232 SubD-9 |
|
External Communication |
SubD 25 Analog and Digital I/O.
Port Power scale 1V=100W. Rear Panel |
|
RF Input / Output Connectors |
INPUT BNC Female
OUTPUT N Female
BLANKING BNC Female
Digital I/O (optional): RS232, USB2 and RS485 |
| AC
Power Source |
200 - 240 VAC, +/-10%; 40 - 60 Hz, +/-10%
(100 to 120 VAC operation possible at up to 50% output level) |
| AC
Power connection |
Permanently attached line cord with plug
(meeting safety requirements of the region where equipment will be
operating).
PFC of 95% at 230 VAC. |
| Cooling |
Water cooled
and forced air, heatsink temperature monitored for equipment safety
at 70C limit. |
| Case |
Designed to
meet EMI and RFI shielding requirements still chassis, blackened.
|
| Dimensions (with
hardware) |
H135mm x
W212mm x L482mm ( 5.25” H x 8.3” x 19) |
| Weight |
14 kg,
31 lbs. |
|
Mounting |
Half Rack, 3U high. Optional: Rack Mount
Kit, Adapter Kit, Coupling Screws. |
|
Operating Temperature |
Temperature: 10° to 35° C ambient air |