| DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class B |
|
Frequency of Operation / Frequency Stability |
13.56 MHz default, adjustable from
13.3 MHz to 13.8 MHz/ 0.005%
|
| RF
Power Output |
>100 Watts into 50 Ohm |
|
Gain (as amplifier) in MGC/Burst Mode |
52 dB @ 100W +/-1dB (0dBm IN Drive) |
| RF Input Drive
(as amplifier) |
Typical
range -20 dBm to 0dBm |
| RF Input Drive for
AGC |
Recommended
0 dBm for the best operation |
Input Drive Source
(amplifier) |
Signal or function generator, analog
computer input capable of up to 2 Vp-p @ 50 Ohm |
- Input and Output
Impedance
|
50 Ohm |
|
Input VSWR |
1.2:1 max |
|
Output VSWR |
3:1 max |
|
Output VSWR Protection |
65W max reflected power limit.
Automatic, limits typically within 0.5 ms after reverse power
reaches 65W or power amplifier current preset limit. |
Harmonic level @
100W
|
Better than
- 40 dBc for 2-nd harmonic, any other > -45 dBc |
| Spurious Output |
- 76 dBm
equivalent noise level generated by internal circuits |
|
Output Blanking |
For pulsed applications, T&C amplifiers
and generators offer blanking of the output signal for minimum noise
RF spectrum |
| Mismatch
Power Output |
Forward Power reference to rating
1:1:1 VSWR, up to 120W,
2:1 load: 120W FWD, 65W LOAD
3:1 load: 60w fwd, 38W LOAD
9:1 load: 32W FWD, 12W LOAD |
|
Dynamic Power Range |
0 to 100W, settings within +/- 2W |
| RF
Output Settings |
-Front Panel EDITOR
-RS 232 port from GUI
-hardware port 1V=100W scale |
|
Pulse Specifications |
Pulse Width: 1 to 500 usec
Period: 1 to 50 milliseconds |
| SWEEP
Operation |
13.3 to 13.8 MHz. Min time 10ms, max
10s.
Settings and activation from GUI only |
|
Power Margin |
28% |
| RF Power
Control |
Front Panel or REmote Power Control via
Hardware Port SubD-25 or RS232 SubD-9 |
|
External Communication |
SubD 25 Analog and Digital I/O.
Port Power scale 1V=100W. Rear Panel |
|
RF Input / Output Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel |
| AC
Power Source |
100 - 240 VAC, +/-10%, 47 - 63 Hz,
broad input voltage with no adjustment required. |
| AC
Power connection |
IEC Standard Power Entry followed by RFI
filter. Filter range 0.1 to 30 MHz min. |
| Cooling |
Forced air,
temperature controlled heatsink temperature monitored for equipment
safety at 70C limit. |
| Case |
Designed to
meet EMI and RFI shielding requirements still chassis, blackened.
|
| Dimensions (with
hardware) |
H135mm x
W211mm x L445mm ( 5.25” H x 8.3” x 17.5) |
| Weight |
10.5 kg,
23.5 lbs. |
|
Mounting |
Half Rack, 3U high. Optional: Rack Mount
Kit, Adapter Kit, Coupling Screws. |
|
Operating Temperature |
Temperature: 10° to 35° C ambient air |