| DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class B |
|
Frequency of Operation / Frequency Stability |
13.56 MHz default, adjustable from
13.3 MHz to 13.8 MHz/ 0.005%
|
| RF
Power Output |
>600 Watts into 50 Ohm |
|
Gain (as amplifier) in MGC/Burst
Mode |
54 dB @ 100W +/-1dB (0dBm IN Drive) |
| RF Input Drive
(as amplifier) |
Typical
range -20 dBm to 5 dBm |
| RF Input Drive for
AGC |
Recommended
+1 to +3 dBm for the best operation |
|
Input Drive Source (amplifier) |
Signal or function generator, analog
computer input capable of up to 1 Vp-p @ 50 Ohm |
- Input and Output
Impedance
|
50 Ohm |
|
Input VSWR |
1.2:1 max |
|
Output VSWR |
3:1 max |
|
Output VSWR Protection |
75W max reflected power limit.
Automatic, limits typically within 0.5 ms after reverse power
reaches 75W or power amplifier current preset limit. |
Harmonic level
|
@300W:
Better than -35 dBc for 2nd harmonic,
h3 and higher > -45 dBc
@550W: Better than -49 dBc for 2nd harmonic,
h3 and higher >-45 dBc |
| Spurious Output |
- 76 dBm
equivalent noise level generated by internal circuits |
|
Output Blanking |
For pulsed applications, our amplifiers
and generators offer blanking of the output signal for minimum noise
RF spectrum |
|
Mismatch Power Output |
Forward Power reference to rating
1:1:1 VSWR (50ohm), up to 650W,
2:1VSWR (25ohm), 210 W min.
3:1 VSWR (15ohm), 145 W min. |
|
Dynamic Power Range |
0 to 650W, settings within +/- 2W |
| RF
Output Settings |
-Front Panel EDITOR
-RS 232 port from GUI
-hardware port 1V=100W scale |
|
Burst Operation |
Pulse Width: 1 to 500 usec
Period: 1 to 50 milliseconds
user settings via GUI and RS232 |
| SWEEP
Operation |
13.3 to 13.8 MHz. Min time 10ms, max
10s.
Settings and activation from GUI only |
|
Power Margin |
28% |
| RF Power
Control |
Front Panel or REmote Power Control via
Hardware Port SubD-25 or RS232 SubD-9 |
|
External Communication |
SubD 25 Analog and Digital I/O.
Port Power scale 1V=100W. Rear Panel |
|
RF Input / Output Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel |
| AC
Power Source |
200 - 240 VAC, +/-10%, 47 - 63 Hz,
broad input voltage with no adjustment required.
Max: 11.5A |
| AC
Power connection |
IEC Standard Power Entry followed by RFI
filter. Filter range 0.1 to 30 MHz min. |
| Cooling |
Forced air,
temperature controlled heatsink temperature monitored for equipment
safety at 70C limit. |
| Case |
Designed to
meet EMI and RFI shielding requirements still chassis, blackened.
|
| Dimensions (with
hardware) |
H135mm x
W211mm x L445mm ( 5.25” H x 8.3” x 17.5) |
| Weight |
10.5 kg,
23.5 lbs. |
|
Mounting |
Half Rack, 3U high. Optional: Rack Mount
Kit, Adapter Kit, Coupling Screws. |
|
Operating Temperature |
Temperature: 10° to 35° C ambient air |