DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class B |
|
Frequency of Operation |
20 kHz to 2 MHz |
|
RF Power Output |
600W from 0.02 MHz to 1.25 MHz of
continues output into any load.
Up to 1000W max from 0.4 MHz to 1.2
MHz, 50 Ohm load only, 20C,
Pulsing and low duty cycle only! |
|
Gain |
60 dB @ 1000W /0.5 MHz +/-1.5 dB 20 kHz to 2 MHz |
|
RF Power Input Drive |
Typical
range -20 dBm to 5 dBm max |
|
RF Power Input Drive for AGC |
Recommended -3 dBm to 0 dBm for +/-0.3
dB gain flatness |
|
Input Drive Source |
Signal or function generator, analog
computer output capable of up to 1 Vp-p @ 50 Ohm (+5dBm) |
|
Internal RF Source |
DDS oscillator: 20 kHz to 2MHz, 1 kHz
resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
|
Output VSWR Protection |
160 W max. reflected power limit |
|
Harmonic level @ 250 W |
Better then
- 19 dBc for any harmonic |
|
Spurious Output |
- 26 dBm
equivalent noise level generated by internal circuits |
|
RF Output Settings & Control |
-Front Panel EDITOR and function
switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear
Panel. |
|
BURST |
Internal settings: Pulse
range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more
details. |
|
SWEEP Operation |
0.02 to 2 MHz. Min time 10 ms, max 10s.
Settings and activation from GUI only |
|
Output Blanking |
For pulsed applications, amplifiers and
generators may offer blanking of the output signal for minimum RF
spectrum noise. Less than 1 mu Rise/Fall time. |
|
RF Connectors |
BNC Female: Back Panel |
|
AC Power Source |
200-240 VAC, +/- 10%, 47-63 Hz |
|
AC Power Connection |
Non-detachable power cord anchored with compression bushing followed
by RFI filter. Back Panel. |
|
AC Circuit Protection |
Internally
fused on the main DC Power Supply, 15A |
|
AC Input Current (RMS) |
RF
Out nominal 600W: I<8A @ 220V
RF Out max 550W: I<13A @ 220V |
|
Cooling |
Forced air,
temperature controlled, heatsink temperature monitored via RS232 GUI
interface. |
|
Acoustic level |
45 dBa @ Max
Fan Speed @ temp. |
|
Case |
Designed to
meet EMI and RFI shielding requirements AL chassis, yellow
conductive finish. |
|
Dimensions (with hardware) |
(H 178 x W
363 x L 388) mm (7” x 14.25” x 15.25” ) |
|
Weight |
25 kg, 54
lbs. |
|
Mounting |
Stand alone unit. (Optional Rack Mount
Kit) |
|
Environmental Conditions |
Temp: 10°C
to 35°C
Humidity: 80% |