  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

LF ULTRASONIC GENERATOR LINEAR AMPLIFIER 


AG 1012 LF Ultrasonic Generator and Power Linear Amplifier
Ultrasonic Industrial Generator and Power Linear Amplifier
AG 1012 LF Ultrasonic Generator and Power Linear Amplifier offers up to 1000 Watts RF Power 
From 20 kHz to 1 MHz for Industrial, Laboratory, and Medical Application.
AGC or Power Leveling: Gain Control to better than ± 0.5 dB

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com
SPECIFICATIONS
DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class B to 1000 Watts
Frequency of Operation 20 kHz to 6 MHz
RF Power Output 600W from 0.02 kHz to 6 MHz of continuous output into any load.
Up to 1000W max from 0.4 MHz to 5 MHz, 50 Ohm load only, 20C
Pulsing and low duty cycle only!
Gain 62 dB @ 200W /0.5 MHz +/-1 dB 20 kHz to 60 MHz (200W Out)
RF Power Input Drive Typical range -20 dBm to 0 dBm, +5 dBm max
RF Power Input Drive for AGC Recommended -3 dBm to 0 dBm for +/-0.3 dB gain flatness
Input Drive Source Signal or function generator, analog computer output capable of up to 1 Vp-p @ 50 Ohm (+5dBm)
Internal RF Source DDS oscillator: 20 kHz to 6 MHz, 1 kHz resolution
 
Input and Output Impedance
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR
Output VSWR Protection 160 W max. reflected power limit
Harmonic level @ 750 W Better then - 15 dBc for 3rd harmonic,
any other > -20 dBc
Spurious Output - 26 dBm equivalent noise level generated by internal circuits
RF Output Settings & Control -Front Panel EDITOR and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear Panel.
RF Power Meter accuracy +/-3% typical
Output Blanking For pulsed applications, amplifiers and generators may offer blanking of the output signal for minimum RF spectrum noise.
Less than 1 mu Rise/Fall time.
BURST Internal settings: Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more details.
SWEEP Operation 0.02 to 6 MHz. Min time 10 ms, max 10s.
Settings and activation from GUI only
RF Connectors INPUT BNC Female
OUTPUT N Female
Rear Panel
AC Power Source 200-240 VAC, +/- 10%, 47-63 Hz
AC Power Connection IEC Standard Power Entry followed by RFI filter. Filter range 0.1 to 30 MHz min
AC Circuit Protection Internally fused on the main DC Power Supply, 15A
AC Input Current (RMS) RF Out nominal 600W: I<8A @ 220V
RF Out max 1000W: I<13A @ 220V
Cooling Forced air, temperature controlled, heatsink temperature monitored via RS232 GUI interface.
Acoustic level 45 dBa @ Max Fan Speed @ temp.
Case Designed to meet EMI and RFI shielding requirements AL chassis, yellow conductive finish.
Dimensions (with hardware) (H 178 x W 363 x L 388) mm (7” x 14.25” x 15.25” )
Optional Half Rack, 3U High.
Weight 25 kg, 54 lbs.
Mounting Stand alone unit. (Optional Rack Mount Kit)
Environmental Conditions Temp: 10°C to 35°C
Humidity: 80%

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or