AG1014 LF POWER AMPLIFIER GENERATOR
AG1014 Power Amplifier and Generator

AG 1014 LF Ultrasonic Generator and Power Linear Amplifier and Generator.
AG 1014 Ultrasonic Generator and Power Linear Amplifier and Generator offers up to 500 Watts RF Power From 20 kHz to 2 MHz for Industrial, Laboratory, and Medical Application.
AGC or Power Leveling: Gain Control to better than ± 0.5 dB

 
  • 20 kHz to 2 MHz up to greater than 550 W
  • Output of 500 Watts with h3</= -20 dBc
  • Digital Meter, measures forward and
    reflected power
  • Data acquisition: analog port for status
    monitoring and power measurement.
  • Front Panel Control of Amplifier and
    generator functions
  • RS232 communication: full control of all
    amplifier and generator functions.
  • AGC or Power Leveling: Gain Control to
    better than ±0.5  dB
SPECIFICATIONS
DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class "B"
Frequency of Operation 20 kHz to 1 MHz
RF Power Output 50 Ohm load: Up to 400W for 20kHz to 2 MHz
Up to 500W for 50 kHz to 1.75 MHz
UP to 550W for 80 kHZ t 1.2 MHz
Pulsing and low duty cycle only!

Any load:
Up to 250W, continuous operation

Gain 57 dB @ 500W /0.45 MHz
+/-1 dB 50 kHz to 2 MHz
RF Power Input Drive for AGC Recommended -5 dBm to 0 dBm for +/-0.5 dB gain flatness
Input and Output Impedance 50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR
Output VSWR Protection 80 W max. reflected power limit
Harmonic level @ 750 W Better then -20 dBc for 3rd harmonic,
any other > -20 dBc
Spurious Output - 26 dBm equivalent noise level generated by internal circuits
RF Output Settings & Control -Front Panel EDITOR and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear Panel.
BURST Internal settings: Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more details
SWEEP Operation 0.02 to 6 MHz. Min time 10 ms, max 10s. Settings and activation from GUI only
Output Blanking For pulsed applications, amplifiers and generators may offer blanking of the output signal for minimum RF spectrum noise. Less than 1 mu Rise/Fall time.
RF Connectors BNC Female: RF In
"N type" Female: RF Out
AC Power Source 200-240 VAC, +/- 10%, 47-63 Hz
AC Input Current (RMS) RF Out nominal 400W: I<5.5A @ 220V
RF Out max 550W: I<6.5A @ 220V
Cooling Forced air, temperature controlled, heatsink temperature monitored via RS232 GUI interface.
Cooling Forced air, temperature controlled, heatsink temperature monitored via RS232 GUI interface.
Acoustic level 45 dBa @ Max Fan Speed @ temp.
Case Designed to meet EMI and RFI shielding requirements AL chassis, yellow conductive finish. Front Panel: off-white. Cover: black.
Dimensions (with hardware) (H 135 x W 254 x L 385) mm (5.25” x 10” x 15” )
Optional Half Rack, 3U High.
Weight 12 kg, 26 lbs
Mounting Stand alone unit. (Optional Rack Mount Kit)
Environmental Conditions Temp: 10°C to 35°C
Humidity: 80%

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or