DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class "A" |
|
Frequency of Operation |
10 kHz to 6 MHz |
|
RF Power Output |
50 Ohm load:
Up to 1000W for 20 kHz to 2 MHz
Up to 750W for 10kHz to 4 MHz
Up to 400W for 10 MHz to 6 MHz
Pulse and low duty cycle!
Any load:
Up to 400W, continuous operation |
|
Gain |
60 dB @ 1000W / 1MHz
+/-1.5 dB 20 kHz to 2 MHz
-2 dB drop: 10kHz to 20kHz and 2 MHz to 6MHz |
|
RF Power Input Drive |
Typical
range -30 dBm to 0 dBm, +5 dBm max |
|
RF Power Input Drive for AGC |
Recommended -5 dBm to 0 dBm for
+/-0.5 dB gain flatness |
|
Input Drive Source |
Signal or function generator, analog
computer output capable of up to 1 Vp-p @ 50 Ohm (+5dBm)
Input range: -30 to 0 dBm typical, +5 dBm max |
|
Internal RF Source |
DDS oscillator: 10 kHz to 6 MHz, 1
kHz resolution |
-
Input and Output
Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
|
Output VSWR Protection |
250 W max. reflected power limit for
load impedance > 50 Ohm. Current level protection for Load
Impedance < 50 Ohm. |
|
Harmonic level |
@ 400 W: Better then -
20 dBc for 3rd harmonic,
any other > -30 dBc
@ 950W: -14 dBc |
|
Spurious Output |
- 26 dBm
equivalent noise level generated by internal circuits |
|
RF Output Settings & Control |
-Front Panel EDITOR and function
switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear
Panel. |
|
Output Blanking |
For pulsed applications, amplifiers
and generators may offer blanking of the output signal for
minimum RF spectrum noise. |
|
BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more
details. |
|
SWEEP Operation |
0.01 to 6MHz. Min time 10 ms, max
10s. Settings and activation from GUI only |
|
RF Connectors |
BNC Female: RF In
HN Female: RF Out |
|
AC Power Source |
200-240 VAC, +/- 10%, 47-63 Hz, No
adjustment required. |
|
AC Power Connection |
See
manual for details |
|
AC Input Current (RMS)
|
RF Out nominal 400W:
I<10A @ 220V
RF Out max 1000W: I<16A @ 220V |
|
Cooling |
Forced
air, temperature controlled, heatsink temperature monitored via
RS232 GUI interface. |
|
Acoustic level |
45 dBa @
Max Fan Speed @ temp. |
|
Case |
Designed
to meet EMI and RFI shielding requirements AL chassis, yellow
conductive finish. |
|
Dimensions (with hardware) |
(H 405 x
W 520 x L 470) mm ( 16” x 20.5” x 18.5” )
Optional Half Rack, 3U High. |
|
Weight |
59 kg,
130 lbs. |
|
Mounting |
Stand alone unit. (Optional Rack
Mount Kit) |
|
Environmental Conditions |
Temp:
10°C to 35°C
Humidity: 80% |