DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class B |
|
Frequency of Operation |
20 kHz to 6 MHz |
|
RF Power Output |
400W for 20 kHz to 6 MHz
500W for 100 kHz to 5 MHz
600W for 150 kHz to 4 MHz |
|
Mismatch Power Output |
Continuous Load Power at
20C:
2:1 VSWR (25 Ohm) 210W min
3:1 VSWR (15 Ohm) 145W min
Limited by Reverse Power Limitter! |
|
Gain |
57 dB @ 500W /0.75 MHz +/-1.5 dB 20 kHz to 6 MHz |
|
RF Power Input Drive for AGC |
Recommended -5 dBm to 0 dBm for +/-0.5
dB gain flatness |
|
Input Drive Source |
Signal or function generator, analog
computer output capable of up to 1 Vp-p @ 50 Ohm. Input range: -30
to 0 dBm typical, +5 dBm max |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
|
Output VSWR Protection |
80 W max. reflected power limit for Load
Impedance > 50 Ohm. Current level protection for Load Impedance < 50
Ohm. |
|
Harmonic level @ 550 W |
Better then
- 14 dBc for 3rd harmonic,
any other > -30 dBc |
|
Spurious Output |
- 76 dBm
equivalent noise level generated by internal circuits approx. -20
dBm continuous level noise present at the amplifier output in 70 kHz
to 150 kHz band |
|
RF Output Settings & Control |
-Front Panel EDITOR and function
switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear
Panel. |
|
BURST |
Internal settings: Pulse
range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more
details. |
|
SWEEP Operation |
0.02 to 6 MHz. Min time 10 ms, max 10s.
Settings and activation from GUI only |
|
Output Blanking |
For pulsed applications our amplifiers and
generators may offer blanking of the output signal for minimum RF
spectrum noise. |
|
RF Connectors |
BNC Female: Back Panel |
|
AC Power Source |
200-240 VAC, +/- 10%, 47-63 Hz, No
adjustment required. Max: 11.5A |
|
AC Power Connection |
IEC Standard
Power Entry followed by RFI filter. Filter range 0.1 to 30 MHz min |
|
Cooling |
Forced air,
temperature controlled, heatsink temperature monitored via RS232 GUI
interface. |
|
Case |
Designed to
meet EMI and RFI shielding requirements AL chassis, yellow
conductive finish. |
|
Dimensions (with hardware) |
(H 135 x W
254 x L 385) mm ( 5.25” x 10” x 15” )
Optional Half Rack, 3U High. |
|
Weight |
12 kg, 26
lbs. |
|
Mounting |
Stand alone unit. (Optional Rack Mount
Kit) |
|
Environmental Conditions |
Temp: 10°C
to 35°C
Humidity: 80% |