DESCRIPTION |
RANGE/CHARACTERISTIC |
|
Class of Operation |
Class A to 100 Watts |
|
Frequency of Operation |
10 kHz to 20 MHz |
|
RF Power Output |
100 W from 0.015 MHz to 12 MHz of
continuous linear output into any load.
Up to 300W total power margin, 50 Ohm resistive load only, 20C,
Pulsing only! |
|
Gain |
53 dB @ 100W / 1MHz
+/-1 dB 20 kHz to 14 MHz (100W Out) |
|
RF Power Input Drive |
Typical
range -30 dBm to 0 dBm, +5 dBm max |
|
RF Power Input Drive for AGC |
Recommended -3 dBm to 0 dBm for +/-0.3
dB gain flatness |
|
Input Drive Source |
Signal or function generator, analog
computer output capable of up to 1 Vp-p @ 50 Ohm (+5dBm) |
|
Internal RF Source |
DDS oscillator: 10 kHz to 6 MHz, 1 kHz
resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
|
Output VSWR Protection |
75 W max. reflected power limit |
|
Harmonic level |
@
100 W: Better then - 20 dBc for 3rd
harmonic,
any other > -30 dBc
@ 250W: -14 dBc |
|
Spurious Output |
- 26 dBm
equivalent noise level generated by internal circuits |
|
RF Output Settings & Control |
-Front Panel EDITOR and function
switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear
Panel. |
|
Output Blanking |
For pulsed applications, T&C amplifiers
and generators may offer blanking of the output signal for minimum
RF spectrum noise. Less than 1 mu Rise/Fall time |
|
RF Power Meter accuracy |
+/- 3% typical |
|
BURST |
Internal settings: Pulse
range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more
details. |
|
SWEEP Operation |
0.01 to 15MHz. Min time 10 ms, max 10s.
Settings and activation from GUI only |
|
RF Connectors |
BNC Female: Front Panel |
|
AC Power Source |
100-120 VAC, 200-240 VAC, +/- 10%, 47-63
Hz, No adjustment required. |
|
AC Power Connection |
IEC Standard
Power Entry followed by RFI filter.
Filter range 0.1 to 30 MHz min |
|
AC Circuit Protection |
Internally
fused on the main DC Power Supply, 15A |
|
AC Input Current (RMS) |
RF
Out nominal 175W: I<7A @ 115V/ I <3A @
220V
RF Out max 300W: I<9A @ 115V/ I < 4A @ 220V |
|
Cooling |
Forced air,
temperature controlled, heatsink temperature monitored via RS232 GUI
interface. |
|
Acoustic level |
45 dBa @ Max
Fan Speed @ temp. |
|
Case |
Designed to
meet EMI and RFI shielding requirements AL chassis, yellow
conductive finish. |
|
Dimensions (with hardware) |
(H 135 x W
254 x L 385) mm ( 5.25” x 10” x 15” )
Optional Half Rack, 3U High. |
|
Weight |
12 kg, 26
lbs. |
|
Mounting |
Stand alone unit. (Optional Rack Mount
Kit) |
|
Environmental Conditions |
Temp: 10°C
to 35°C
Humidity: 80% |