wpe2.jpg (7450 bytes)
MULTIFUNCTION FLUE GAS ANALYZER
  
Testo 300XXL Flue Gas Analyzer

300XXL Flue Gas Analyzer Control Unit.
testo 300 XXL control unit, displays measurement data and controls the analysis box, with built-in printer, backlit display, temperature and pressure measurement, 1 user defined probe socket (leak detection probe, ambient CO probe, ambient air probes), RS 232 interface, data memory for 4000 data blocks.
All measurement tasks on all gas, oil and solid fuel burners can be carried out flexibly (CO optional up to 30000 ppm) using the testo 300 XXL measurement system.

  • Integrated printer for documenting readings
    on-site

  • 8 user defined function buttons (4 virtual)

  • Integrated differential pressure measurement

  • User defined probe socket

  • RS232 interface, data exchange with Testo or branch software

 

Technical Data
Probe type (measuring value) Measuring range  
Current/voltage measurement
(Voltage DC)
-1000.0 ... 1000.0 mV Accuracy  +/-1.0 mV  (-1000.0 ... 1000.0 mV)
    Resolution +/-1.0 mV  (-1000.0 ... 1000.0 mV)
Current/voltage measurement
(Voltage DC)
-10.0 ... 10.0 V Accuracy  +/-0.01 V  (-10.0 ... 10.0 V)
    Resolution +/-0.01 V  (-10.0 ... 10.0 V)
Type K (NiCr-Ni)
(Temperature)
-200.0 ... 1370.0 °C Accuracy  +/-1.0 °C  (-200.0 ... -100.1 °C)
+/-0.4 °C  (-100.0 ... 200.0 °C)
+/-1.0 °C  (200.1 ... 1370.0 °C)
    Resolution +/-0.1 °C  (-200.0 ... 1370.0 °C)
Type K (NiCr-Ni)
(Temperature)
-328.0 ... 2498.0 °F Accuracy  +/-1.0 °F  (-328.0 ... -148.1 °F)
+/-0.4 °F  (-148.0 ... 391.9 °F)
+/-1.0 °F  (392.0 ... 2498.0 °F)
    Resolution +/-0.1 °F  (-328.0 ... 2498.0 °F)
Pt100
(Temperature)
-200.0 ... 800.0 °C Accuracy  +/-1.0 °C  (-200.0 ... -100.0 °C)
+/-0.4 °C  (-99.9 ... -50.0 °C)
+/-0.1 °C  (-49.9 ... 99.9 °C)
+/-0.4 °C  (100.0 ... 199.9 °C)
+/-1.0 °C  (200.0 ... 800.0 °C)
    Resolution +/-0.1 °C  (-200.0 ... -100.0 °C)
+/-0.01 °C  (-99.99 ... 300.0 °C)
+/-0.1 °C  (300.1 ... 800.0 °C)
Pt100
(Temperature)
-328.0 ... 1472.0 °F Accuracy  +/-1.0 °F  (-328.0 ... -148.1 °F)
+/-0.4 °F  (-148.0 ... -58.1 °F)
+/-0.1 °F  (-58.0 ... 211.9 °F)
+/-0.4 °F  (212.0 ... 391.9 °F)
+/-1.0 °F  (392.0 ... 1472.0 °F)
    Resolution +/-0.1 °F  (-328.0 ... -148.1 °F)
+/-0.01 °F  (-148.0 ... 571.9 °F)
+/-0.1 °F  (572.0 ... 1472.0 °F)
NTC
(Temperature)
-40.0 ... 150.0 °C Accuracy  +/-0.4 °C  (-40.0 ... -10.1 °C)
+/-0.2 °C  (-10.0 ... 50.0 °C)
+/-0.4 °C  (50.1 ... 150.0 °C)
    Resolution +/-0.1 °C  (-40.0 ... 150.0 °C)
NTC
(Temperature)
-40.0 ... 302.0 °F Accuracy  +/-0.4 °F  (-40.0 ... -14.1 °F)
+/-0.2 °F  (-14.0 ... 121.9 °F)
+/-0.4 °F  (122.0 ... 302.0 °F)
    Resolution +/-0.1 °F  (-40.0 ... 302.0 °F)
Type S (Pt10Rh-Pt)
(Temperature)
0.0 ... 1760.0 °C Accuracy  +/-1.0 °C  (0.0 ... 1760.0 °C)
    Resolution +/-1.0 °C  (0.0 ... 1760.0 °C)
Type S (Pt10Rh-Pt)
(Temperature)
32.0 ... 3200.0 °F Accuracy  +/-1.0 °F  (32.0 ... 3200.0 °F)
    Resolution +/-1.0 °F  (32.0 ... 3200.0 °F)
Type J (Fe-CuNi)
(Temperature)
-200.0 ... 1000.0 °C Accuracy  +/-1.0 °C  (-200.0 ... -150.1 °C)
+/-0.4 °C  (-150.0 ... 150.0 °C)
+/-1.0 °C  (150.1 ... 1000.0 °C)
    Resolution +/-0.1 °C  (-200.0 ... 1000.0 °C)
Type J (Fe-CuNi)
(Temperature)
-328.0 ... 1832.0 °F Accuracy  +/-1.0 °F  (-328.0 ... -238.1 °F)
+/-0.4 °F  (-238.0 ... 301.9 °F)
+/-1.0 °F  (302.0 ... 1832.0 °F)
    Resolution +/-0.1 °F  (-328.0 ... 1832.0 °F)
Testo humid. sensor, cap.
(Humidity)
0.0 ... 100.0 %rF Resolution  +/-0.1 %rF  (0.0 ... 100.0 %rF)
Thermal
(Flow)
0.0 ... 20.0 m/s Accuracy  +/-0.01 m/s  (0.0 ... 1.99 m/s)
+/-0.02 m/s  (2.0 ... 4.99 m/s)
+/-0.04 m/s  (5.0 ... 20.0 m/s)
    Resolution +/-0.01 m/s  (0.0 ... 20.0 m/s
Pressure sensor 1
(Differential pressure)
-1000.0 ... 1000.0 hPa Accuracy  +/-2.0% of mv  (-200.0 ... -1000.0 hPa)
+/-4.0 hPa  (-199.9 ... 199.9 hPa)
+/-2.0% of mv  (200.0 ... 1000.0 hPa)
    Resolution +/-0.1 hPa  (-1000.0 ... 1000.0 hPa)
Pressure sensor 2
(Differential pressure)
-80.0 ... 80.0 hPa Accuracy  +/-1.5% of mv  (-50.0 ... -80.0 hPa)
+/-0.5 hPa  (-49.9 ... 49.9 hPa)
+/-1.5% of mv  (50.0 ... 80.0 hPa)
    Resolution +/-0.0%   (-80.0 ... 80.0 hPa)
CO probe
(Carbon monoxide)
0.0 ... 500.0 ppm CO Accuracy  +/-5.0% of mv  (0.0 ... 500.0 ppm CO)
CO2 probe
(Carbon dioxide)
0.0 ... 1.0 Vol. % CO2    
Mechanical
(rpm)
20.0 ... 20000.0 U/min Resolution  +/-1.0 U/min  (20.0 ... 20000.0 U/min)
Current/voltage measurement
(Current 2)
0.0 ... 20.0 mA Accuracy  +/-0.04 mA  (0.0 ... 20.0 mA)
    Resolution +/-0.01 mA  (0.0 ... 20.0 mA)
Vane
(Flow)
0.0 ... 60.0 m/s    
Type T (Cu-CuNi)
(Temperature)
-40.0 ... 350.0 °C Accuracy  +/-0.4 °C  (-40.0 ... 200.0 °C)
+/-1.0 °C  (200.1 ... 350.0 °C)
    Resolution +/-0.1 °C  (-40.0 ... 350.0 °C)
CO2 probe
(Carbon dioxide)
0.0 ... 10000.0 ppm CO2 Accuracy  +/-5.0% of mv  (0.0 ... 10000.0 ppm CO2)
Type T (Cu-CuNi)
(Temperature)
-40.0 ... 662.0 °F Accuracy  +/-0.4 °F  (-40.0 ... 391.9 °F)
+/-1.0 °F  (392.0 ... 662.0 °F)
    Resolution +/-0.1 °F  (-40.0 ... 662.0 °F)

 

Storage temperature -20.0...50.0 °C
Operation temperature -5.0...45.0 °C
Battery type 4 AA batteries 
Battery life 7.0 h
Weight 850.0 g
Dimensions (B x L x H) 115.0 x 252.0 x 58.0  mm

 