| Technical Data |
327-2 |
| Temperature measurement: |
|
| Measuring range: |
-40 to +600 °C |
| Accuracy: |
±0.5 °C (0 to +99,9 °C)
±0.5 % of m.v. (from +100°C) |
| Resolution: |
0.1 °C |
| Measurement value sensor: |
Thermocouple Type K (NiCr-Ni) acc. to
DIN IEC 584, Part 2, Class 1 |
| Draught / pressure measurement: |
|
| Draught: |
±40 hPa |
| Accuracy: |
±0.02 hPa (-0.50 to +0.60 hPa)
±0.03hP. (+0.61 to +3.00 hPa)
1.5 %of m.v. (+3.01 to +40 hPa) |
| Resolution: |
±0.01 hPa (fine draught option: 0.001
hPa) |
| Delta P: |
±200 hPa |
| Accuracy: |
±0,5 hPa (0 to +50 hPa)
±1.0 % of m.v. (+50.1 to +100.0 hPa)
± 1.5 % of m.v. (+100.1 to +200.0 hPa) |
| Resolution: |
0.1 hPa (Option
Fine Delta P 0.01 hPa) |
| Determination of efficiency (ETA) |
|
| Measuring range: |
0 to 120 % |
| Resolution: |
0.1 % |
| Exhaust loss: |
|
| Measuring range: |
0 to 99.9 % |
| Resolution: |
0.1 % |
| O2 measurement: |
|
| Measuring range: |
0 to 21 Vol.% |
| Accuracy: |
±0.2 Vol.% |
| Resolution: |
0.1 % |
| Adjustment time t90: |
approx. 40 sec. |
| CO2 recording: |
|
| Display range: |
0 to CO2max |
| Accuracy: |
±0.2 Vol.% |
| Resolution: |
0.01 Vol.% |
| Recording: |
dig. calculation from
aus O2 |
| Adjustment time t90 |
approx. 40 sec. |
| CO measurement: |
|
| Measuring range: |
0 to 4000 ppm |
| Accuracy: (H2 content< 10%) |
±20 ppm (up to 400
ppm)
±5 % of m.v. (up to 1000 ppm)
±10 % of m.v. (up to 4000 ppm) |
| Option (H2 - compensated) |
|
| Measuring range: |
0 to 8000 ppm |
| Accuracy: |
±20 ppm (up to
200ppm)
±5 % of m.v. (up to 2000 ppm)
±10 % of m.v. (up to 8000 ppm) |
| Resolution: |
1 ppm |
| General technical data: |
|
| Weight: |
approx. 500 g |
| Dimensions: |
216x68x47 |
| Transport / storage temperature: |
-20 to +50 °C |
| Ambient temperature: |
-5 to +45 °C |
| Power supply: |
Li-ion rech. battery |
| Battery life: |
> 10h |