Toll Free: 866-436-2430                     Email: sales@hotektech.com

 
 
Instruments, calibrators, standards, analyzers, dataloggers. analyzers
 
  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

FLUE GAS CO CO2 EXHAUST GAS ANALYZER


330-1 Flue Gas Analyzer. CO, CO2, Pressure, Exhaust Gas, NO, O2, Efficiency.
330-1 Flue Gas Analyzer incl. rechargeable battery and calibration protocol.
The major benefits of the flue gas analyzer lie in its dialog functions: Instrument diagnosis provides information at the touch of a button about the qualitative status of functions such as on the level in the condensate trap but also on wearing parts, for example, the state of the measurement cells. Maintenance intervals are displayed, making your work easier to plan.

 Flue Gas Analyzer CO, CO2
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

The times in which an analyzer lets the user down belong to the past.
Modular probes, such as ΔT, ΔP, flue gas are recognized automatically by the analyzer and the measurement results appear immediately in the menu. The probes have a quick connection function ensuring that all gas paths are connected correctly. The single cable is rigid, indestructible and saves space. The particle filter is positioned in the probe handle.
Probe shafts with different lengths and diameters can be easily attached to the probe handle.

Memory 200
Display Graphics display: 160 x 240 pixel
Storage temperature -20 to +50 °C
Operating temperature -5 to +45 °C
Weight 600 g
Dimensions 270 x 90 x 65 mm
Probe type Type K
Meas. Range -40 to +1200 °C
Accuracy ±0,5 °C (0.0 to +100.0 °C)
±0,5 % of mv (remaining range)
Resolution 0.1 °C (-40 to 999,9 °C)
1 °C (remaining range)
Probe type CO
Meas. Range 0 to 500 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5% of mv (>100 ppm)
Resolution 1 ppm
Response time Approx. 35 s
Probe type CO2
Meas. Range 0 to 1 Vol. %
0 to 10000 ppm
Accuracy ±(50 ppm ±2 % of mv) (0 to 5000 ppm)
Response time Approx. 35 s
Probe type Differential pressure
Meas. Range 0 to 200 hPa
Accuracy ±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (remaining range)
Resolution 0.1 hPa
Probe type
Meas. Range -9.99 to +40 hPa
Accuracy ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Probe type NO
Meas. Range 0 to 300 ppm
Accuracy ±2 ppm (0.0 to 40.0 ppm)
±5% of mv (remaining range)
Reaction time < 30 s
Probe type Exhaust gas loss measurement
Meas. Range 0 to 99.9 %
Resolution 0.1 %
Probe type Electrochemical measurement CO
Meas. Range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)
±5% of mv (401 to 1000 ppm)
±10% of mv (1001 to 4000 ppm)
Resolution 1 ppm
Probe type Electrochemical measurement NO
Meas. Range 0 to 3000 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5% of mv (101 to 2000 ppm)
±10% of mv (2001 to 3000 ppm)
Resolution 1 ppm
Probe type Electrochemical measurement O2
Meas. Range 0 to 21 Vol. %
Accuracy ±0.2 Vol. %
Resolution 0.1 Vol. %
Probe type Efficiency Measurement (Eta)
Meas. Range 0 to 120 %
Resolution 0.1 %
Probe type
Meas. Range 0 to CO2 max
Accuracy ±0.2 Vol. %
Reaction time t90 < 40 s

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [Top] [Distribution] [Contact Us]