  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

FLUE GAS NO O2 CO CO2 ANALYZER


330-2 Flue Gas Analyzer. CO, CO2, Pressure, Exhaust Gas, NO, O2, Efficiency.
Flue gas analyzer incl. rechargeable battery and calibration protocol.
The analyzer is a reliable companion, regardless of whether it is for breakdowns or emergencies, when monitoring legal limits or during daily maintenance assignments. It supports the rapid change between measurement and maintenance. The probe can remain positioned in the flue during the initialization phase of the measurement cells. Calibration is completed in just 30 seconds.

 Flue Gas Analyzer
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Fuel selection, for example, can also be carried out simultaneously and the analyzer is ready for operation. Instrument diagnosis provides information at the touch of a button about the qualitative status of functions such as on the level in the condensate trap but also on wearing parts, for example, the state of the measurement cells. NO low measurements can be carried out on low NOx burners. For applications in extreme conditions, such as highly contaminated burners, Testo's patented technology guarantees efficient display of the CO level up to 30,000 ppm.
The measurement cell is not subjected to any more strain than during normal measurements.

Memory 200
Display Graphics display 160 x 240 pixel
Storage temperature -20 to +50 °C
Operating temperature -5 to +45 °C
Weight 600 g
Dimensions 270 x 90 x 65 mm
Probe type Type K
Meas. Range -40 to +1200 °C
Accuracy ±0,5 °C (0.0 to +100.0 °C)
±0,5 % of mv (remaining range)
Resolution 0.1 °C (-40 to 999,9 °C)
1 °C (remaining range)
Probe type CO
Meas. Range 0 to 500 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5% of mv (>100 ppm)
Resolution 1 ppm
Response time Approx. 35 s
Probe type CO2
Meas. Range 0 to 1 Vol. %
0 to 10000 ppm
Accuracy ±(50 ppm ±2 % of mv) (0 to 5000 ppm)
Response time Approx. 35 s
Probe type Differential pressure
Meas. Range 0 to 200 hPa
Accuracy ±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (remaining range)
Resolution 0.1 hPa
Probe type
Meas. Range -9.99 to +40 hPa
Accuracy ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Probe type NO
Meas. Range 0 to 300 ppm
Accuracy ±2 ppm (0.0 to 40.0 ppm)
±5% of mv (remaining range)
Reaction time < 30 s
Probe type Exhaust gas loss measurement
Meas. Range 0 to 99.9 %
Resolution 0.1 %
Probe type Electrochemical measurement CO
Meas. Range 0 to 8000 ppm
Accuracy ±10 ppm or ±10% of mv (0 to 200 ppm)
±20 ppm or ±5% of mv (201 to 2000 ppm)
±10% of mv (2001 to 8000 ppm)
Resolution 1 ppm
Probe type Electrochemical measurement NO
Meas. Range 0 to 3000 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5% of mv (101 to 2000 ppm)
±10% of mv (2001 to 3000 ppm)
Resolution 1 ppm
Probe type Electrochemical measurement O2
Meas. Range 0 to 21 Vol. %
Accuracy ±0.2 Vol. %
Resolution 0.1 Vol. %
Probe type Efficiency Measurement (Eta)
Meas. Range 0 to 120 %
Resolution 0.1 %
Probe type
Meas. Range 0 to CO2 max
Accuracy ±0.2 Vol. %
Reaction time t90 < 40 s