wpe2.jpg (7450 bytes)
FLUE GAS ANALYZER
Testo 330-3 Flue Gas Analyzer

330-3 Flue Gas Analyzer. CO, CO2, Pressure, Exhaust Gas, NO, O2, Efficiency.
Flue gas analyzer incl. rechargeable battery and calibration protocol
The analyzer offers the heating technician everything he requires to competently carry out his inspections: the analyzer has a special menu and automatic mean calculation. The course of the temperature during hot spot detection is shown in graphs on the display. Draught measurement is also shown in the same menu; the probe can remain positioned in the flue during the initialization phase.

 
  • Instrument diagnosis

  • Automatic instrument leak test

  • ΔT measurement, flow/return

  • Ambient CO2 measurement

  • ΔP measurement for gas pressure

  • Gas/oil flow measurement

  • Recognition of probe connected

  • Initialization of pressure sensor for draught measurement without removing probe

  • 400 data sets incl. object address and
    systems number

  • IRDA interface for data transfer to PDA/Notebook

  • USB interface for data transfer to PC

  • ZIV driver for all standard industrial software

  • Menu with manual CO switch-off function and qA mean value

  • Easy change probe shaft with menu recognition

  • TÜV approved easy-to-change measurement cells

This improves measurement accuracy when checking systems and helps to save you time.
CO switch-off can be carried out manually if necessary. Instrument diagnosis provides you with information about the qualitative status of functions and wearing parts. Included is the quality check on measurement cells, filter status, level display in the condensate trap, leak-proofness of instrument, pump capacity, rechargeable battery status and the date of the last maintenance.

Memory 400
Display Graphics display 160 x 240 pixel
Storage temperature -20 to +50 °C
Operating temperature -5 to +45 °C
Weight 600 g
Dimensions 270 x 90 x 65 mm
Probe type Type K
Meas. Range -40 to +1200 °C
Accuracy ±0,5 °C (0.0 to +100.0 °C)
±0,5 % of mv (remaining range)
Resolution 0.1 °C (-40 to 999,9 °C)
1 °C (remaining range)
Probe type CO
Meas. Range 0 to 500 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5% of mv (>100 ppm)
Resolution 1 ppm
Response time Approx. 35 s
Probe type CO2
Meas. Range 0 to 1 Vol. %
0 to 10000 ppm
Accuracy ±(50 ppm ±2 % of mv) (0 to 5000 ppm)
Response time Approx. 35 s
Probe type Differential pressure
Meas. Range 0 to 200 hPa
Accuracy ±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (remaining range)
Resolution 0.1 hPa
Probe type
Meas. Range -9.99 to +40 hPa
Accuracy ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Probe type NO
Meas. Range 0 to 300 ppm
Accuracy ±2 ppm (0.0 to 40.0 ppm)
±5% of mv (remaining range)
Reaction time < 30 s
Probe type Exhaust gas loss measurement
Meas. Range 0 to 99.9 %
Resolution 0.1 %
Probe type Electrochemical measurement CO
Meas. Range 0 to 8000 ppm
Accuracy ±10 ppm or ±10% of mv (0 to 200 ppm)
±20 ppm or ±5% of mv (201 to 2000 ppm)
±10% of mv (2001 to 8000 ppm)
Resolution 1 ppm
Probe type Electrochemical measurement NO
Meas. Range 0 to 3000 ppm
Accuracy ±5 ppm (0 to 100 ppm)
±5% of mv (101 to 2000 ppm)
±10% of mv (2001 to 3000 ppm)
Resolution 1 ppm
Probe type Electrochemical measurement O2
Meas. Range 0 to 21 Vol. %
Accuracy ±0.2 Vol. %
Resolution 0.1 Vol. %
Probe type Efficiency Measurement (Eta)
Meas. Range 0 to 120 %
Resolution 0.1 %
Probe type
Meas. Range 0 to CO2 max
Accuracy ±0.2 Vol. %
Reaction time t90 < 40 s

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or