  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

PLATINUM RESISTANCE THERMOMETER PRT


5187SA Platinum Resistance Thermometer PRT. High Precision Platinum Thermometer.
Platinum Resistance thermometer is designed to realize, with the highest accuracy, the International Temperature Scale ITS-90 over the range -189°C to 66O°C.
The design is the result of many years practical experience and cooperation with the National Physical Laboratory

High precision PRT Platinum resistance thermometer

Platinum Resistance Thermometer

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Platinum Resistance Thermometer PRT construction

The resistance element is of pure platinum coiled and mounted in a strain free construction. 
The former is of fused silica and great care is taken to ensure freedom from contamination.
All the joints are welded, the four leads from the element to the seal in the thermometer head are heavier gauge platinum thereby avoiding the generation of thermal e.m.f.'s at the junction with the element.
The leads are brought through a hermetic seal at the head of the thermometer and joined via low loss terminals to copper flex in a specially constructed cable with four conductors. 
The cable is made with PTFE insulation to ensure low dielectric loss so that the thermometer may be used with either d.c. or a.c. measuring systems. The terminations are gold plated copper spade tags. The thermometer tube is specially treated to avoid radiation loss by the piping effect in its walls. 
Each thermometer is supplied with a purpose-made carrying case.

Stainless Steel Sheath

To reduce the possibility of damage the Type 5187SA thermometer may be supplied with a protective stainless steel sheath, outside diameter 8-9mm, fitted into the thermometer head by means of three screws. The thermometer is calibrated without the sheath and when this is in position the response time is increased to about 20 seconds

Platinum Resistance Thermometer PRT specifications

Temperature Range:  -189°C to 660°C Calibration: Suitable for calibration to ITS-90 up to max temp 660.323°C (F.P. Aluminum)
Resistance at 0°C (Rtp): 
 25 Ohms +/- 0.5Ohm
R(Ga)/R(tp):  Ratio not less than 1.11807
R(Me)/R(tp):  Ratio not greater than 0.844235
Reproducibility: +/-0.001°C Gas Filling:  Dry air at 1/3 atmosphere
Basic Accuracy:  +/-0.001°C Dimensions: 
Sheath - diameter 6.5 to 7.5 length 480 mm
Head - diameter 23 mm length 60 mm
Overall length: 540 mm 
Immersion depth:  300mm
Self heating:  0.002°C to 0.003°C with 1mA and the thermometer bulb immersed in unstirred water Leads:  Supplied with 4 meters of PTFE insulated cable fitted with gold plated copper spade tags.
Case Size: 67 x 16 x 7 cm Net Weight: Including thermometer 1.15kg

Calibration

CALIBRATION OF PLATINUM RESISTANCE THERMOMETERS TO INTERNATIONAL TEMPERATURE SCALE (ITS-90)
The table below sets out the types of calibration available from NPL and their uncertainties
Point Temperature°C Uncertainty °C
Range 1 Range 2 Range 3 Range4
TP argon -189.3442   0.002 0.002 0.002
TP mercury -38.8344 0.0005 0.0005 0.001 0.002
TP water 0.01 0.0005 0.0005 0.001 0.002
MP Gallium 29.7646 0.0005      
FP indium 156.5985   0.001    
FP tin 231.928   0.001 0.001 0.002
FP zinc 419.527     0.001 0.002
FP aluminum 660.323       0.004

 


The Type 5187SA Platinum Resistance Thermometer maximum calibration will be 660.232°C.
Note: TP - Triple point, MP  -Melting point, FP - Freezing point.