CABLE
TERMINATION UNIT
|
|
|
|
|
5941 Cable Termination Unit for non-repeatered
submarine cables.
The Tinsley 5941 CTU is
the ideal termination unit for non-repeatered submarine
cables.
It offers a simple method of selecting an open or short circuit
condition and a safe means of discharging the cable. The unit is
designed to enable the Test Engineer to safely and simply connect
other Tinsley test instruments to the system for fault location and
electroding.
|
|
| Our
Price: |
Contact us for
pricing |
| Phone:
|
253-927-6186
866-318-6186 |
| Fax:
|
253-927-6189 |
| email:
|
sales@hotektech.com |
|
|
|
|
|
|
|
The Tinsley 5941 CTU
also incorporates a Cable Condition Monitor. Any changes in the
Submarine Cable electrical characteristics are automatically
detected and an alarm is triggered. An output from the alarm is also available for connection to outside
devices.
The unit can
be connected to the cable via a dedicated cable connected to the fiber optic cable metallic conductor.
Alternatively, the fiber optic cable can be routed into the CTU with a direct path through the unit
for the optical fibres. Options that can be set at the time of installation enable the unit to be used with a wide range of cable lengths and types.
|
|
5941 SPECIFICATIONS
|
|
|
| INPUT SUPPLY VOLTAGE |
36V TO 60V DC |
|
MAXIMUM SUPPLY CURRENT
|
1.5A |
|
OPEN CIRCUIT OUTPUT VOLTAGE (Input 48v)
|
-100V |
OUTPUT VOLTAGE STABILITY
(max. load & supply variation) |
± 1V |
| SHORT CIRCUIT CURRENT - NORMAL
DRIVE |
213 ± 13 mA |
|
SHORT CIRCUIT CURRENT- HIGH DRIVE
|
297 ± 35 mA |
|
ALARM LEVEL RANGE
|
-333 mA to + 333 mA |
|
ALARM LEVEL STABILITY
(with load, supply and temperature variation)
|
± 2.5% |
| ALARM CONTACTS RATING |
100V 0.5A DC |
|
MAXIMUM ALLOWABLE
CABLE POWER
|
600V PEAK VOLTAGE
4A CURRENT |
|
OPERATING TEMPERATURE RANGE
|
0șC TO 40șC |
|
SURGE ARRESTOR RATING:-
|
| MAX. SURGE CURRENT |
20KA |
| DC SPARK OVER VOLTAGE |
700V |
|
IMPULSE SPARK OVER VOLTAGE
|
1400V |
|